EN ISO 5840:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Cardiovascular implants - Cardiac valve prostheses (ISO 5840:2005)
09-01-2015
05-13-2009
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviations
5 Fundamental requirements
6 Device description
7 Verification testing and analysis/Design validation
Annex A (informative) - Rationale for the provisions of
this International Standard
Annex B (informative) - Heart valve substitute hazards,
associated failure modes and
evaluation methods
Annex C (informative) - Risk assessment guidelines
Annex D (informative) - Examples and definitions of some
physical and material properties
of heart valve substitutes and
their components
Annex E (informative) - Statistical procedures when using
performance criteria
Annex F (informative) - In vitro procedures for testing
unstented or similar valves
in compliant chambers
Annex G (informative) - Preclinical in vivo tests
Annex H (informative) - Echocardiographic protocol
Annex I (informative) - Description of the heart valve
substitute
Annex J (informative) - Figures of examples of components
of some heart valve substitutes
Annex K (informative) - Examples of standards applicable
to testing of materials and components
of some heart valve substitutes
Annex L (informative) - Guidelines for verification of
hydrodynamic performance
Annex M (informative) - Durability testing
Annex N (informative) - Examples of design specific testing
Annex O (informative) - Fatigue assessment
Annex P (normative) - Packaging
Annex Q (normative) - Labelling and instructions for use
Annex R (normative) - Methods of evaluating clinical data
Annex S (normative) - Sterilization
Bibliography
Annex ZA (informative) - Relationship between this European
Standard and the Essential Requirements
of EU Directive 93/42/EEC
ISO 5840:2005 is applicable to all devices intended for implantation in human hearts, as a heart valve substitute.It is applicable to both newly developed and modified heart valve substitutes and to the accessory devices, packaging and labelling required for their implantation and for determining the appropriate size of heart valve substitute to be implanted.ISO 5840:2005 outlines an approach for qualifying the design and manufacture of a heart valve substitute through risk management. The selection of appropriate qualification tests and methods are derived from the risk assessment. The tests may include those to assess the physical, chemical, biological and mechanical properties of heart valve substitutes and of their materials and components. The tests may also include those for pre-clinical in vivo evaluation and clinical evaluation of the finished heart valve substitute.ISO 5840:2005 imposes design specifications and minimum performance specifications for heart valve substitutes where adequate scientific and/or clinical evidence exists for their justification.It excludes heart valve substitutes designed for implantation in artificial hearts or heart assist devices.
Committee |
CEN/TC 285
|
DevelopmentNote |
Supersedes EN 12006-1. (03/2006) Supersedes UNE EN 12006-1. (08/2006)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NF EN ISO 5840 : OCT 2009 | Identical |
DIN EN ISO 5840:2009-08 | Identical |
NBN EN ISO 5840 : 2009 | Identical |
UNI EN ISO 5840 : 2009 | Identical |
BS EN ISO 5840:2009 | Identical |
NS EN ISO 5840 : 2009 | Identical |
NEN EN ISO 5840 : 2009 | Identical |
ISO 5840:2005 | Identical |
I.S. EN ISO 5840:2009 | Identical |
SN EN ISO 5840 : 2009 | Identical |
UNE-EN ISO 5840:2009 | Identical |
PN EN ISO 5840 : 2009 | Identical |
VDI 5700 Blatt 1:2015-04 | Reprocessing hazards - Risk management in reprocessing of medical devices - Measures for risk control |
EN 12442-3 : 2000 | ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 3: VALIDATION OF THE ELIMINATION AND/OR INACTIVATION OF VIRUSES AND TRANSMISSIBLE AGENTS |
ISO 14160:2011 | Sterilization of health care products Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives Requirements for characterization, development, validation and routine control of a sterilization process for medical devices |
ISO 11135:2014 | Sterilization of health-care products — Ethylene oxide — Requirements for the development, validation and routine control of a sterilization process for medical devices |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
ISO 14937:2009 | Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices |
ISO 14155-1:2003 | Clinical investigation of medical devices for human subjects Part 1: General requirements |
ISO 10993-2:2006 | Biological evaluation of medical devices — Part 2: Animal welfare requirements |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
ISO 8601:2004 | Data elements and interchange formats Information interchange Representation of dates and times |
ISO 532:1975 | Acoustics Method for calculating loudness level |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
ISO 11607:2003 | Packaging for terminally sterilized medical devices |
EN 12442-1 : 2000 | ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 1: ANALYSIS AND MANAGEMENT OF RISK |
ISO 11134:1994 | Sterilization of health care products — Requirements for validation and routine control — Industrial moist heat sterilization |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
MIL-STD-1629 Revision A:1980 | PROCEDURES FOR PERFORMING A FAILURE MODE, EFFECTS AND CRITICALITY ANALYSIS |
ISO 11137:1995 | Sterilization of health care products Requirements for validation and routine control Radiation sterilization |
IEC 60651:1979+AMD1:1993+AMD2:2000 CSV | Sound level meters |
EN 12442-2 : 2000 | ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 2: CONTROLS ON SOURCING, COLLECTION AND HANDLING |