EN ISO 389-3:2016
Current
The latest, up-to-date edition.
Acoustics - Reference zero for the calibration of audiometric equipment - Part 3: Reference equivalent threshold vibratory force levels for pure tones and bone vibrators (ISO 389-3:2016)
02-17-2016
European foreword
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Reference equivalent threshold vibratory
force levels (RETVFL)
5 Test conditions and requirements
Annex A (informative) - Note on the derivation of
RETVFL values
Annex B (informative) - Guidance on the application
of the reference zero to the calibration of bone-conduction
audiometers
Annex C (informative) - Differences in reference equivalent
threshold vibratory force levels between forehead and
mastoid location of vibrator
Annex D (informative) - Bone-conduction threshold of hearing
for frequencies below 250 Hz
Bibliography
ISO 389-1:2016 specifies the following data applicable to the calibration of bone vibrators for pure-tone bone-conduction audiometry:a) reference equivalent threshold vibratory force levels (RETVFL), corresponding to the threshold of hearing of young otologically normal persons by bone-conduction audiometry;b) essential characteristics of the bone vibrator and the method of coupling to the test subject, and to the mechanical coupler;c) essential characteristics of the masking noise and the baseline masking noise level applied to the ear not under test.Guidance on the practical application of this part of ISO 389 in the calibration of audiometers is given in Annex B.RETVFL is the vibratory force level transmitted to a mechanical coupler of specified characteristics by a vibrator when applied to the mechanical coupler under stated conditions of test and when energized at the voltage level corresponding to the normal threshold of hearing for location on the mastoid prominence.NOTE 1 Values for the differences in reference equivalent threshold vibratory force levels between location on the forehead and mastoid are included for information in Annex C.NOTE 2 Recommended procedures for carrying out bone-conduction audiometry are specified in ISO 8253‑1.
Committee |
CEN/TC 211
|
DevelopmentNote |
Supersedes EN 27566. (04/2005)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
DIN EN ISO 389-3:1999-07 | Identical |
SS-EN ISO 389-3:2016 | Identical |
NEN EN ISO 389-3 : 2016 | Identical |
NF EN ISO 389-3 : 2016 | Identical |
SN EN ISO 389-3 : 2016 | Identical |
UNI EN ISO 389-3 : 1999 | Identical |
NS EN ISO 389-3 : 1998 | Identical |
UNE-EN ISO 389-3:2016 | Identical |
PN EN ISO 389-3 : 2016 | Identical |
DIN EN ISO 389-3:2016-06 | Identical |
UNI EN ISO 389-3:2016 | Identical |
BS EN ISO 389-3:2016 | Identical |
ISO 389-3:2016 | Identical |
I.S. EN ISO 389-3:2016 | Identical |
NBN EN ISO 389-3 : 1999 | Identical |
BS EN 15927:2010 | Services offered by hearing aid professionals |
09/30198066 DC : 0 | BS EN 15927 - SERVICES OFFERED BY HEARING AID PROFESSIONALS |
NF EN 15927 : 2010 | SERVICES OFFERED BY HEARING AID PROFESSIONALS |
I.S. EN 15927:2010 | SERVICES OFFERED BY HEARING AID PROFESSIONALS |
CEI EN 60645-1 : 2016 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AUDIOMETRY |
UNI EN 15927 : 2010 | SERVICES OFFERED BY HEARING AID PROFESSIONALS |
EN 15927:2010 | Services offered by hearing aid professionals |
UNE-EN 15927:2011 | Services offered by hearing aid professionals |
I.S. EN 60645-1:2017 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY |
BS EN 60645-1:2017 | Electroacoustics. Audiometric equipment Equipment for pure-tone and speech audiometry |
UNE-EN 60645-1:2015 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone audiometry |
EN 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
IEC 60318-6:2007 | Electroacoustics - Simulators of human head and ear - Part 6: Mechanical coupler for the measurement on bone vibrators |
ISO 389-4:1994 | Acoustics Reference zero for the calibration of audiometric equipment Part 4: Reference levels for narrow-band masking noise |
ANSI S3.13 : 1987 | MECHANICAL COUPLER FOR MEASUREMENT OF BONE VIBRATORS |
ISO 4869-1:1990 | Acoustics Hearing protectors Part 1: Subjective method for the measurement of sound attenuation |
ISO 389-8:2004 | Acoustics — Reference zero for the calibration of audiometric equipment — Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones |
ISO 389-1:1998 | Acoustics Reference zero for the calibration of audiometric equipment Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones |
ISO 8253-1:2010 | Acoustics Audiometric test methods Part 1: Pure-tone air and bone conduction audiometry |
IEC 61260-1:2014 | Electroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications |
ISO 389-2:1994 | Acoustics Reference zero for the calibration of audiometric equipment Part 2: Reference equivalent threshold sound pressure levels for pure tones and insert earphones |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.