EN ISO 22674:2016
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Dentistry - Metallic materials for fixed and removable restorations and appliances (ISO 22674:2016)
08-31-2016
02-24-2016
European foreword
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Classification
5 Requirements
6 Sampling
7 Preparation of test specimens
8 Test methods
9 Information and instructions for use
Annex A (informative) - Tensile testing of a non-cast Type
0 metallic material that is intended for use in a
thickness between 0,1 mm and 0,5 mm
Annex B (normative) - Calculation of uncertainty for elasticity
measurement
Annex C (informative) - Measurement of Poisson ratio
Bibliography
ISO 22674:2016 classifies metallic materials that are suitable for the fabrication of dental restorations and appliances, including metallic materials recommended for use either with or without a ceramic veneer, or recommended for both uses, and specifies their requirements. Furthermore, it specifies requirements with respect to packaging and marking the products and to the instructions to be supplied for the use of these materials, including products delivered for sale to a third party.ISO 22674:2016 does not apply to alloys for dental amalgam (ISO 24234), dental brazing materials (ISO 9333), or metallic materials for orthodontic appliances (ISO 15841) (e.g. wires, brackets, bands and screws).
Committee |
CEN/TC 55
|
DevelopmentNote |
Supersedes EN ISO 1562, EN ISO 16744, EN ISO 6871-1, EN ISO 6871-2 and EN ISO 8891. (05/2007)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
Supersedes |
Standards | Relationship |
ONORM EN ISO 22674 : 2016 | Identical |
DS EN ISO 22674 : 2016 | Identical |
NF EN ISO 22674 : 2016 | Identical |
ISO 22674:2016 | Identical |
NBN EN ISO 22674 : 2016 | Identical |
NEN EN ISO 22674 : 2016 | Identical |
NS EN ISO 22674 : 2006 | Identical |
I.S. EN ISO 22674:2016 | Identical |
PN EN ISO 22674 : 2016 | Identical |
SN EN ISO 22674 : 2016 | Identical |
UNI EN ISO 22674 : 2007 | Identical |
SS-EN ISO 22674:2016 | Identical |
UNI EN ISO 22674:2016 | Identical |
UNE-EN ISO 22674:2016 | Identical |
BS EN ISO 22674:2016 | Identical |
DIN EN ISO 22674:2016-09 | Identical |
08/30184612 DC : DRAFT SEP 2008 | BS EN 1641 - DENTISTRY - MEDICAL DEVICES FOR DENTISTRY - MATERIALS |
DIN EN 1641:2010-02 | Dentistry - Medical devices for dentistry - Materials |
I.S. EN 1641:2009 | DENTISTRY - MEDICAL DEVICES FOR DENTISTRY - MATERIALS |
UNI EN 1641 : 2010 | DENTISTRY - MEDICAL DEVICES FOR DENTISTRY - MATERIALS |
BS EN 1641:2004 | Dentistry. Medical devices for dentistry. Materials |
EN 1641:2009 | Dentistry - Medical devices for dentistry - Materials |
ISO 9333:2006 | Dentistry — Brazing materials |
ISO 24234:2015 | Dentistry Dental amalgam |
ISO 10271:2011 | Dentistry Corrosion test methods for metallic materials |
ISO 6892-1:2016 | Metallic materials Tensile testing Part 1: Method of test at room temperature |
ISO 5832-3:2016 | Implants for surgery Metallic materials Part 3: Wrought titanium 6-aluminium 4-vanadium alloy |
ISO 7405:2008 | Dentistry Evaluation of biocompatibility of medical devices used in dentistry |
ISO 9513:2012 | Metallic materials — Calibration of extensometer systems used in uniaxial testing |
ISO 15841:2014 | Dentistry Wires for use in orthodontics |
ISO 1942:2009 | Dentistry Vocabulary |
ISO 9693-1:2012 | Dentistry Compatibility testing Part 1: Metal-ceramic systems |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
ISO 5832-2:1999 | Implants for surgery Metallic materials Part 2: Unalloyed titanium |
ISO 12781-1:2011 | Geometrical product specifications (GPS) Flatness Part 1: Vocabulary and parameters of flatness |
ISO 3696:1987 | Water for analytical laboratory use — Specification and test methods |
ISO 28319:2010 | Dentistry Laser welding |
ISO 6344-1:1998 | Coated abrasives Grain size analysis Part 1: Grain size distribution test |
ISO 7500-1:2015 | Metallic materials Calibration and verification of static uniaxial testing machines Part 1: Tension/compression testing machines Calibration and verification of the force-measuring system |
ISO 15223-1:2016 | Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.