EN ISO 16212:2017
Current
The latest, up-to-date edition.
Cosmetics - Microbiology - Enumeration of yeast and mould (ISO 16212:2017)
07-05-2017
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principles
5 Diluents, neutralizers and culture media
6 Apparatus and glassware
7 Strain of microorganisms
8 Handling of cosmetic products and laboratory samples
9 Procedure
10 Counting of colonies (plate counts and membrane
filtration methods)
11 Expression of results
12 Neutralization of the antifungicidal properties of the
product
13 Test report
Annex A (informative) - Other neutralizing diluents
Annex B (informative) - Other diluents
Annex C (informative) - Other culture media
Annex D (informative) - Neutralizers of antifungicidal
activity of preservatives and rinsing liquids
Bibliography
ISO 16212:2017 gives general guidelines for enumeration of yeast and mould present in cosmetics by counting the colonies on selective agar medium after aerobic incubation.In order to ensure product quality and safety for consumers, it is advisable to perform an appropriate microbiological risk analysis to determine the types of cosmetic products to which ISO 16212:2017 is applicable. Products considered to present a low microbiological risk (see ISO 29621) include those with low water activity or extreme pH values, hydro-alcoholic products, etc.Because of the large variety of cosmetic products within this field of application, this method might not be suited to some products in every detail (e.g. certain water-immiscible products). Other methods (e.g. automated) can be substituted for the tests presented here provided that their equivalence has been demonstrated or the method has been otherwise shown to be suitable.Yeast enumerated can be identified using suitable identification tests, for example, tests described in the standards listed in the Bibliography. Mould enumerated can be identified by other appropriate methods, if necessary.
Committee |
CEN/TC 392
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
DIN EN ISO 16212:2017-09 | Identical |
DS EN ISO 16212 : 2011 | Identical |
DIN EN ISO 16212:2011-08 | Identical |
NBN EN ISO 16212 : 2011 | Identical |
NEN EN ISO 16212 : 2017 | Identical |
UNI EN ISO 16212 : 2011 | Identical |
ONORM EN ISO 16212 : 2018 | Identical |
SS-EN ISO 16212:2017 | Identical |
BS EN ISO 16212:2017 | Identical |
I.S. EN ISO 16212:2017 | Identical |
SN EN ISO 16212 : 2017 | Identical |
UNE-EN ISO 16212:2017 | Identical |
NF EN ISO 16212 : 2017 | Identical |
ISO 16212:2017 | Identical |
UNI EN ISO 16212 : 2017 | Identical |
PN-EN ISO 16212:2017-08 | Identical |
NS EN ISO 16212 : 2017 | Identical |
EN 13624:2013 | Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of fungicidal or yeasticidal activity in the medical area - Test method and requirements (phase 2, step 1) |
ISO 29621:2017 | Cosmetics — Microbiology — Guidelines for the risk assessment and identification of microbiologically low-risk products |
EN 12353:2013 | Chemical disinfectants and antiseptics - Preservation of test organisms used for the determination of bactericidal (including Legionella), mycobactericidal, sporicidal, fungicidal and virucidal (including bacteriophages) activity |
ISO 18415:2017 | Cosmetics — Microbiology — Detection of specified and non-specified microorganisms |
ISO 18416:2015 | Cosmetics Microbiology Detection of Candida albicans |
ISO 21148:2017 | Cosmetics — Microbiology — General instructions for microbiological examination |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.