EN ISO 15883-7:2016
Current
The latest, up-to-date edition.
Washer-disinfectors - Part 7: Requirements and tests for washer-disinfectors employing chemical disinfection for non-invasive, non-critical thermolabile medical devices and healthcare equipment (ISO 15883-7:2016)
03-09-2016
European foreword
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Performance requirements
5 Mechanical requirements
6 Testing for conformity
7 Documentation
8 Information to be provided by the manufacturer
9 Marking, labelling, and packaging
10 Information to be requested from the purchaser
by the manufacturer
Annex A (normative) - Summary of test programmes
Annex B (normative) - Methods for microbiological
evaluation of disinfection of liquid transport system
Annex C (normative) - Tests for microbiological
contamination of post-disinfection rinse water
Annex D (normative) - Preparation and evaluation of
indicators for microbiological testing of the efficacy
of chemical disinfection of the load
Annex E (informative) - Examples of test locations for the
tests with biological indicators
Bibliography
Annex ZA (informative) - Relationship between this
European Standard and the essential
requirements of Directive 93/42/EEC [OJ L 169]
aimed to be covered
ISO 15883-7:2016 specifies the particular requirements for washer-disinfectors (WD) intended to be used for the cleaning and chemical disinfection, in a single operating cycle, of reusable items such as the following:a) bedframes;b) bedside tables;c) transport carts;d) containers;e) surgical tables;f) sterilization containers;g) surgical clogs;h) wheelchairs, aids for the disabled.ISO 15883-7:2016 also specifies the performance requirements for the cleaning and disinfection of the washer-disinfector and its components and accessories which may be necessary in order to achieve the required performance.Devices identified within the scopes of ISO 15883‑2, ISO 15883‑3, ISO I5883-4, and ISO 15883‑6 do not fall within the scope of this part of ISO 15883.In addition, the methods are specified, as well as instrumentation and instructions required for type testing, works testing, validation (installation, operation, and performance qualification on first installation), routine control, and monitoring, as well as requalifications required to be carried out periodically and after essential repairs.NOTE WDs corresponding to this part of ISO 15883 can also be used for cleaning and chemical disinfection of other thermolabile and reusable devices as recommended by the device manufacturer.The performance requirements specified in this part of ISO 15883 may not ensure the inactivation or removal of the causative agent(s) (prion proteins) of Transmissible Spongiform Encephalopathies.
Committee |
CEN/TC 102
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
DIN EN ISO 15883-7:2016-10 | Identical |
DIN EN ISO 15883-7 E : 2016 | Identical |
NF EN ISO 15883-7 : 2016 | Identical |
ISO 15883-7:2016 | Identical |
NS EN ISO 15883-7 : 2016 | Identical |
SN EN ISO 15883-7 : 2016 | Identical |
I.S. EN ISO 15883-7:2016 | Identical |
NBN EN ISO 15883-7 : 2016 | Identical |
NEN EN ISO 15883-7 : 2016 | Identical |
BS EN ISO 15883-7:2016 | Identical |
UNE-EN ISO 15883-7:2016 | Identical |
PN EN ISO 15883-7 : 2016 | Identical |
SS-EN ISO 15883-7:2016 | Identical |
UNI EN ISO 15883-7 : 2016 | Identical |
ÖNORM EN ISO 15883-7: 2016 09 01 | Identical |
EN ISO 11737-2:2009 | Sterilization of medical devices - Microbiological methods - Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process (ISO 11737-2:2009) |
IEC 61010-2-040:2015 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials |
EN 13624:2013 | Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of fungicidal or yeasticidal activity in the medical area - Test method and requirements (phase 2, step 1) |
ISO 15883-1:2006 | Washer-disinfectors Part 1: General requirements, terms and definitions and tests |
EN ISO 15883-3:2009 | Washer-disinfectors - Part 3: Requirements and tests for washer-disinfectors employing thermal disinfection for human waste containers (ISO 15883-3:2006) |
EN 61010-2-040:2015 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040 Particular requirements for sterilizers and washer-disinfectors used to treat medical materials |
ISO 11737-1:2006 | Sterilization of medical devices Microbiological methods Part 1: Determination of a population of microorganisms on products |
ISO 15883-6:2011 | Washer-disinfectors — Part 6: Requirements and tests for washer-disinfectors employing thermal disinfection for non-invasive, non-critical medical devices and healthcare equipment |
ISO 15883-3:2006 | Washer-disinfectors — Part 3: Requirements and tests for washer-disinfectors employing thermal disinfection for human waste containers |
CEN ISO/TS 15883-5:2005 | Washer-disinfectors - Part 5: Test soils and methods for demonstrating cleaning efficacy (ISO/TS 15883-5:2005) |
EN 14348:2005 | Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of mycobactericidal activity of chemical disinfectants in the medical area including instrument disinfectants - Test methods and requirements (phase 2, step 1) |
EN 10088-2:2014 | Stainless steels - Part 2: Technical delivery conditions for sheet/plate and strip of corrosion resisting steels for general purposes |
EN ISO 15883-4:2009 | Washer-disinfectors - Part 4: Requirements and tests for washer-disinfectors employing chemical disinfection for thermolabile endoscopes (ISO 15883-4:2008) |
EN 13727:2012+A2:2015 | Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of bactericidal activity in the medical area - Test method and requirements (phase 2, step 1) |
EN ISO 15883-6:2015 | Washer-disinfectors - Part 6: Requirements and tests for washer-disinfectors employing thermal disinfection for non-invasive, non-critical medical devices and healthcare equipment (ISO 15883-6:2011) |
ISO/TS 15883-5:2005 | Washer-disinfectors Part 5: Test soils and methods for demonstrating cleaning efficacy |
ISO 15883-4:2008 | Washer-disinfectors Part 4: Requirements and tests for washer-disinfectors employing chemical disinfection for thermolabile endoscopes |
EN 14476:2013+A1:2015 | Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of virucidal activity in the medical area - Test method and requirements (Phase 2/Step 1) |
EN 1040:2005 | Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of basic bactericidal activity of chemical disinfectants and antiseptics - Test method and requirements (phase 1) |
ISO 15883-2:2006 | Washer-disinfectors — Part 2: Requirements and tests for washer-disinfectors employing thermal disinfection for surgical instruments, anaesthetic equipment, bowls, dishes, receivers, utensils, glassware, etc. |
EN ISO 15883-2:2009 | Washer-disinfectors - Part 2: Requirements and tests for washer-disinfectors employing thermal disinfection for surgical instruments, anaesthetic equipment, bowls, dishes, receivers, utensils, glassware, etc. (ISO 15883-2:2006) |
EN 10088-1:2014 | Stainless steels - Part 1: List of stainless steels |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.