EN ISO 10993-7 : 2008 COR 2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS (ISO 10993-7:2008/COR 1:2009)
01-21-2022
11-15-2009
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
4.1 General
4.2 Categorization of devices
4.3 Allowable limits
4.4 Determination of EO and ECH residuals
5 Product release
5.1 General
5.2 Release of products without dissipation curve data
5.3 Procedure for product release using residue dissipation
curves
Annex A (normative) - Evaluation of gas chromatograms
Annex B (informative) - Gas chromatographic determination
for EO and ECH
Annex C (informative) - Flowchart and guidance for the
application of this part of ISO
10993 series of standards to the
determination of EO and ECH residuals
in medical devices
Annex D (informative) - Factors influencing product residual
Annex E (informative) - Extraction conditions for
determination of residual EO
Annex F (informative) - Rationale for the provisions of this
part of ISO 10993
Annex G (informative) - Establishment of allowable limits for
EO
Annex H (informative) - Establishment of allowable limits for
ECH
Annex I (informative) - Establishment of allowable limits for
EG
Annex J (informative) - Preparation of EO and ECH standards
Annex K (informative) - Ethylene oxide residue measuring
methods
Bibliography
Annex ZA (informative) - Relationship between this International
Standard and the Essential Requirements
of EU Directive 93/42/EEC Medical
devices
Annex ZB (informative) - Relationship between this International
Standard and the Essential Requirements
of EU Directive 90/385/EEC on Active
Implantable Medical Devices
Describes allowable limits for residual ethylene oxide (EO) and ethylene chlorohydrin (ECH) in individual EO-sterilized medical devices, procedures for the measurement of EO and ECH, and methods for determining compliance so that devices may be released.
Committee |
TC 206
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
ONORM EN ISO 10993-7 : 2010 | Identical |
NBN EN ISO 10993-7 : 2008 COR 2009 | Identical |
PN EN ISO 10993-7 : 2009 AC 2010 | Identical |
UNE-EN ISO 10993-7:2009 | Identical |
SN EN ISO 10993-7 : 2008 CORR 2009 | Identical |
BS EN ISO 10993-7:2008 | Identical |
UNI EN ISO 10993-7 : 2009 | Identical |
NF EN ISO 10993-7 : 2008 | Identical |
I.S. EN ISO 10993-7:2008+AC:2009 | Identical |
DIN EN ISO 10993-7:2009-02 | Identical |
NEN EN ISO 10993-7 : 2008 C1 2009 | Identical |
I.S. EN ISO 10993-7:2008 | Identical |
ISO 10993-7:2008 | Identical |
NS EN ISO 10993-7 : 2008 AC 2009 | Identical |
I.S. EN 12022:1999 | BLOOD GAS EXCHANGERS |
I.S. EN 13503-8:2000 | OPHTHALMIC IMPLANTS - INTRAOCULAR LENSES - PART 8: FUNDAMENTAL REQUIREMENTS |
DIN EN ISO 7199:2015-06 (Draft) | CARDIOVASCULAR IMPLANTS AND ARTIFICIAL ORGANS - BLOOD-GAS EXCHANGERS (OXYGENATORS) (ISO 7199:2016) |
I.S. EN ISO 7198:2017 | CARDIOVASCULAR IMPLANTS AND EXTRACORPOREAL SYSTEMS - VASCULAR PROSTHESES - TUBULAR VASCULAR GRAFTS AND VASCULAR PATCHES (ISO 7198:2016) |
UNE-EN ISO 7198:2017 | Cardiovascular implants and extracorporeal systems - Vascular prostheses - Tubular vascular grafts and vascular patches (ISO 7198:2016) |
DIN EN 1422:2014-08 | STERILIZERS FOR MEDICAL PURPOSES - ETHYLENE OXIDE STERILIZERS - REQUIREMENTS AND TEST METHODS |
BS EN 12006-2 : 1998 | NON-ACTIVE SURGICAL IMPLANTS - PARTICULAR REQUIREMENTS FOR CARDIAC AND VASCULAR IMPLANTS - PART 2: VASCULAR PROSTHESES INCLUDING CARDIAC VALVE CONDUITS |
EN 12011 : 1998 | INSTRUMENTATION TO BE USED IN ASSOCIATION WITH NON-ACTIVE SURGICAL IMPLANTS - GENERAL REQUIREMENTS |
EN 13503-8 : 2000 | OPHTHALMIC IMPLANTS - INTRAOCULAR LENSES - PART 8: FUNDAMENTAL REQUIREMENTS |
EN 12022:1999 | Blood gas exchangers |
PREN 1422 : DRAFT 2011 | STERILIZERS FOR MEDICAL PURPOSES - ETHYLENE OXIDE STERILIZERS - REQUIREMENTS AND TEST METHODS |
11/30252448 DC : 0 | BS EN 1422 - STERILIZERS FOR MEDICAL PURPOSES - ETHYLENE OXIDE STERILIZERS - REQUIREMENTS AND TEST METHODS |
BS EN ISO 7199:2017 | Cardiovascular implants and artificial organs. Blood-gas exchangers (oxygenators) |
I.S. EN 1422:2014 | STERILIZERS FOR MEDICAL PURPOSES - ETHYLENE OXIDE STERILIZERS - REQUIREMENTS AND TEST METHODS |
DIN EN 1422:1997-11 | STERILIZERS FOR MEDICAL PURPOSES - ETHYLENE OXIDE STERILIZERS - REQUIREMENTS AND TEST METHODS |
I.S. EN 12442-1:2000 | ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 1: ANALYSIS AND MANAGEMENT OF RISK |
BS EN 12022:1999 | Blood-gas exchangers |
BS EN 12442-1:2000 | Animal tissues and their derivatives utilized in the manufacture of medical devices Analysis and management of risk |
I.S. EN 12006-2:1998 | NON ACTIVE SURGICAL IMPLANTS - PARTICULAR REQUIREMENTS FOR CARDIAC AND VASCULAR IMPLANTS - PART 2: VASCULAR PROSTHESES INCLUDING CARDIAC VALVE CONDUITS |
UNI EN 12006-2 : 2009 | NON ACTIVE SURGICAL IMPLANTS - PARTICULAR REQUIREMENTS FOR CARDIAC AND VASCULAR IMPLANTS - PART 2: VASCULAR PROSTHESES INCLUDING CARDIAC VALVE CONDUITS |
UNI EN 1422 : 2014 | STERILIZERS FOR MEDICAL PURPOSES - ETHYLENE OXIDE STERILIZERS - REQUIREMENTS AND TEST METHODS |
BS EN ISO 25539-1:2017 | Cardiovascular implants. Endovascular devices Endovascular prostheses |
I.S. EN 12011:1998 | INSTRUMENTATION TO BE USED IN ASSOCIATION WITH NON-ACTIVE SURGICAL IMPLANTS - GENERAL REQUIREMENTS |
I.S. EN ISO 25539-1:2017 | CARDIOVASCULAR IMPLANTS - ENDOVASCULAR DEVICES - PART 1: ENDOVASCULAR PROSTHESES (ISO 25539-1:2017) |
BS EN 13503-8:2000 | Ophthalmic implants. Intraocular lenses Fundamental requirements |
EN ISO 7198:2017 | Cardiovascular implants and extracorporeal systems - Vascular prostheses - Tubular vascular grafts and vascular patches (ISO 7198:2016) |
EN 12006-2:1998+A1:2009 | Non active surgical implants - Particular requirements for cardiac and vascular implants - Part 2: Vascular prostheses including cardiac valve conduits |
EN 1422:2014 | Sterilizers for medical purposes - Ethylene oxide sterilizers - Requirements and test methods |
BS EN ISO 7198:2017 | Cardiovascular implants and extracorporeal systems. Vascular prostheses. Tubular vascular grafts and vascular patches |
I.S. EN ISO 7199:2017 | CARDIOVASCULAR IMPLANTS AND ARTIFICIAL ORGANS - BLOOD-GAS EXCHANGERS (OXYGENATORS) (ISO 7199:2016) |
DIN EN 12006-2:2009-08 | NON ACTIVE SURGICAL IMPLANTS - PARTICULAR REQUIREMENTS FOR CARDIAC AND VASCULAR IMPLANTS - PART 2: VASCULAR PROSTHESES INCLUDING CARDIAC VALVE CONDUITS |
BS EN 1422:2014 | Sterilizers for medical purposes. Ethylene oxide sterilizers. Requirements and test methods |
EN ISO 7199:2017 | Cardiovascular implants and artificial organs - Blood-gas exchangers (oxygenators) (ISO 7199:2016) |
EN 12442-1 : 2000 | ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 1: ANALYSIS AND MANAGEMENT OF RISK |
ISO 10993-3:2014 | Biological evaluation of medical devices — Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity |
AAMI ST30 : 1989 | DETERMINING RESIDUAL ETHYLENE CHLOROHYDRIN AND ETHYLENE GLYCOL IN MEDICAL DEVICES |
AAMI ST29 : 1988 | DETERMINING RESIDUAL ETHYLENE OXIDE IN MEDICAL DEVICES |
ISO 11135-1:2007 | Sterilization of health care products Ethylene oxide Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO 10993-10:2010 | Biological evaluation of medical devices Part 10: Tests for irritation and skin sensitization |
AAMI ST43 : 3ED 93 | GOOD HOSPITAL PRACTICE: ETHYLENE OXIDE GAS - VENTILATION RECOMMENDATIONS AND SAFE USE |
ISO 10993-12:2012 | Biological evaluation of medical devices Part 12: Sample preparation and reference materials |
ISO 10993-17:2002 | Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.