EN IEC 61076-3-119:2018
Current
The latest, up-to-date edition.
Connectors for electrical and electronic equipment - Product requirements - Part 3-119: Rectangular connectors - Detail specification for shielded and unshielded, free and fixed 10-way connectors with push-pull coupling for industrial environments for data transmission with frequencies up to 100 MHz
03-16-2018
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Technical information
5 Dimensional information
6 Characteristics
7 Test schedule
Annex ZA (normative) - Normative references to
international publications with their corresponding
European publications
IEC 61076-3-119:2017(E) establishes specifications and test requirements for 10-way shielded and unshielded rectangular, free and fixed connectors, with push-pull coupling, for data transmission with frequencies up to 100 MHz and for use in industrial environments.This document specifies free and fixed connectors with round contacts, suitable for screw or crimp terminations. Other terminations techniques, such as solder or printed board connections are upon agreement between manufacturer and user. The free and fixed connectors have a push-pull locking mechanism for IP65 and IP67 protection according to IEC 60529.Connectors according this document are without breaking capacity COC according to 3.9 of IEC 61984:2008, therefore they are not intended to be engaged or disengaged in normal use when live or under load, if not otherwise specified by the manufacturer.Key words: Connectors, Rectangular Connectors, 10 Way Connectors, Push-Pull Coupling
Committee |
CLC/SR 48B
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
UNE-EN IEC 61076-3-119:2018 | Identical |
CEI EN IEC 61076-3 : 2018 | Identical |
DIN EN IEC 61076-3-119 : 2018-12 | Identical |
OVE EN 61076-3-119: 2019 01 01 | Identical |
BS EN IEC 61076-3-119:2018 | Identical |
VDE 0687-76-3-119:2018-12 | Identical |
IEC GUIDE 109:2012 | Environmental aspects - Inclusion in electrotechnical product standards |
IEC 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
EN 60352-2:2006/A1:2013 | SOLDERLESS CONNECTIONS - PART 2: CRIMPED CONNECTIONS - GENERAL REQUIREMENTS, TEST METHODS AND PRACTICAL GUIDANCE |
IEC 60512-11-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-4: Climatic tests - Test 11d: Rapid change of temperature |
IEC 60512-11-9:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-9: Climatic tests - Test 11i: Dry heat |
IEC 60512-11-10:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-10: Climatic tests - Test 11j: Cold |
EN 60512-11-9:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-9: Climatic tests - Test 11i: Dry heat |
IEC 61984:2008 | Connectors - Safety requirements and tests |
IEC 60512-3-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 3-1: Insulation tests - Test 3a: Insulation resistance |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN ISO 1101:2017 | Geometrical product specifications (GPS) - Geometrical tolerancing - Tolerances of form, orientation, location and run-out (ISO 1101:2017) |
EN 60512-11-1:1999 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 11: Climatic tests - Section 1: Test 11a - Climatic sequence |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
IEC 60512-13-5:2006 | Connectors for electronic equipment - Tests and measurements - Part 13-5: Mechanical operation tests - Test 13e: Polarizing and keying method |
EN 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
IEC 60512-6-3:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-3: Dynamic stress tests - Test 6c: Shock |
EN 60512-11-12:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-12: Climatic tests - Test 11m: Damp heat, cyclic |
EN 60512-15-7:2008 | Connectors for electronic equipment - Tests and measurements - Part 15-7: Connector tests (mechanical) - Test 15g: Robustness of protective cover attachment |
EN 60512-15-6:2008 | Connectors for electronic equipment - Tests and measurements - Part 15-6: Connector tests (mechanical) - Test 15f: Effectiveness of connector coupling devices |
IEC 60512-15-1:2008 | Connectors for electronic equipment - Tests and measurements - Part 15-1: Connector tests (mechanical) - Test 15a: Contact retention in insert |
ISO 1101:2017 | Geometrical product specifications (GPS) — Geometrical tolerancing — Tolerances of form, orientation, location and run-out |
EN ISO 1302:2002 | Geometrical Product Specifications (GPS) - Indication of surface texture in technical product documentation (ISO 1302:2002) |
EN 60512-26-100:2008/A1:2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 26-100: MEASUREMENT SETUP, TEST AND REFERENCE ARRANGEMENTS AND MEASUREMENTS FOR CONNECTORS ACCORDING TO IEC 60603-7 - TESTS 26A TO 26G |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
ISO 11469:2016 | Plastics — Generic identification and marking of plastics products |
IEC 60512-13-2:2006 | Connectors for electronic equipment - Tests and measurements - Part 13-2: Mechanical operation tests - Test 13b: Insertion and withdrawal forces |
IEC 62430:2009 | Environmentally conscious design for electrical and electronic products |
IEC 60512-5-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 5-1: Current-carrying capacity tests - Test 5a: Temperature rise |
EN ISO 11469:2016 | Plastics - Generic identification and marking of plastics products (ISO 11469:2016) |
EN 60512-11-3:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-3: Climatic tests - Test 11c: Damp heat, steady state |
EN 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
IEC 60512-16-5:2008 | Connectors for electronic equipment - Tests and measurements - Part 16-5: Mechanical tests on contacts and terminations - Test 16e: Gauge retention force (resilient contacts) |
EN 60512-5-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 5-1: Current-carrying capacity tests - Test 5a: Temperature rise |
EN 60512-6-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-4: Dynamic stress tests - Test 6d: Vibration (sinusoidal) |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
EN 60512-13-2 : 2006 COR 2006 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 13-2: MECHANICAL OPERATION TESTS - TEST 13B: INSERTION AND WITHDRAWAL FORCES |
EN 60352-5:2012/AC:2014 | SOLDERLESS CONNECTIONS - PART 5: PRESS-IN CONNECTIONS - GENERAL REQUIREMENTS, TEST METHODS AND PRACTICAL GUIDANCE (IEC 60352-5:2012) |
EN 60512-15-1 : 2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 15-1: CONNECTOR TESTS (MECHANICAL) - TEST 15A: CONTACT RETENTION IN INSERT |
ISO 1302:2002 | Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation |
IEC 60512-26-100:2008+AMD1:2011 CSV | Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g |
EN 60512-11-7:2003 | Connectors for electronic equipment - Tests and measurements - Part 11- 7: Climatic tests - Test 11g: Flowing mixed gas corrosion test |
IEC 60512-11-3:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-3: Climatic tests - Test 11c: Damp heat, steady state |
EN 60512-1-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-2: General examination - Test 1b: Examination of dimension and mass |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60512-1-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination |
IEC 60352-5:2012 | Solderless connections - Part 5: Press-in connections - General requirements, test methods and practical guidance |
EN 60512-16-5:2008 | Connectors for electronic equipment - Tests and measurements - Part 16-5: Mechanical tests on contacts and terminations - Test 16e: Gauge retention force (resilient contacts) |
IEC 60512-11-1:1995 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 11: Climatic tests - Section 1: Test 11a - Climatic sequence |
IEC 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |
IEC 60512-9-1:2010 | Connectors for electronic equipment - Tests and measurements - Part 9-1: Endurance tests - Test 9a: Mechanical operation |
EN 62430:2009 | Environmentally conscious design for electrical and electronic products |
IEC 60512-11-7:2003 | Connectors for electronic equipment - Tests and measurements - Part 11-7: Climatic tests - Test 11g: Flowing mixed gas corrosion test |
EN 60512-3-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 3-1: Insulation tests - Test 3a: Insulation resistance |
IEC 60512-11-12:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-12: Climatic tests - Test 11m: Damp heat, cyclic |
EN 60512-11-10:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-10: Climatic tests - Test 11j: Cold |
IEC 60512-4-1:2003 | Connectors for electronic equipment - Tests and measurements - Part 4-1: Voltage stress tests - Test 4a: Voltage proof |
EN 62197-1 : 2006 | CONNECTORS FOR ELECTRONIC EQUIPMENT - QUALITY ASSESSMENT REQUIREMENTS - PART 1: GENERIC SPECIFICATION |
IEC 60352-2:2006+AMD1:2013 CSV | Solderless connections - Part 2: Crimped connections - Generalrequirements, test methods and practical guidance |
EN 60512-13-5:2006/corrigendum Dec. 2006 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 13-5: MECHANICAL OPERATION TESTS - TEST 13E: POLARIZING AND KEYING METHOD |
EN 60999-1:2000 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included) |
IEC 62197-1:2006 | Connectors for electronic equipment - Quality assessment requirements - Part 1: Generic specification |
EN 61984:2009 | Connectors - Safety requirements and tests |
IEC 60512-15-7:2008 | Connectors for electronic equipment - Tests and measurements - Part 15-7: Connector tests (mechanical) - Test 15g: Robustness of protective cover attachment |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60512-4-1:2003 | Connectors for electronic equipment - Tests and measurements - Part 4-1: Voltage stress tests - Test 4a: Voltage proof |
EN 60512-1-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination |
EN 60512-6-3:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-3: Dynamic stress tests - Test 6c: Shock |
IEC 60512-6-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-4: Dynamic stress tests - Test 6d: Vibration (sinusoidal) |
IEC 60512-15-6:2008 | Connectors for electronic equipment - Tests and measurements - Part 15-6: Connector tests (mechanical) - Test 15f: Effectiveness of connector coupling devices |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60512-1-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-2: General examination - Test 1b: Examination of dimension and mass |
EN 60512-9-1:2010 | Connectors for electronic equipment - Tests and measurements - Part 9-1: Endurance tests - Test 9a: Mechanical operation |
EN 60512-11-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-4: Climatic tests - Test 11d: Rapid change of temperature |
EN 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |