EN 62271-203:2012
Current
The latest, up-to-date edition.
High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
05-11-2012
FOREWORD
1 General
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
5 Design and construction
6 Type tests
7 Routine tests
8 Guide to the selection of switchgear and
controlgear
9 Information to be given with enquiries,
tenders and orders
10 Transport, storage, installation, operation
and maintenance
11 Safety
12 Influence of the product on the environment
Annex A (normative) - Test procedure for dielectric
test on three-phase encapsulated GIS, range II
Annex B (normative) - Methods for testing gas-insulated
metal-enclosed switchgear under conditions of
arcing due to an internal fault
Annex C (informative) - Technical and practical
considerations of site testing
Annex D (informative) - Calculation of pressure rise
due to an internal fault
Annex E (informative) - Information to be given with
enquiries, tenders and orders
Annex F (informative) - Service continuity
Annex G (informative) - Insulation levels for GIS with
rated voltages higher than 800 kV
Annex H (informative) - List of notes concerning
certain countries
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Annex ZB (informative) - A-deviations
IEC 62271-203:2011 specifies requirements for gas-insulated metal-enclosed switchgear in which the insulation is obtained, at least partly, by an insulating gas other than air at atmospheric pressure, for alternating current of rated voltages above 52 kV, for indoor and outdoor installation, and for service frequencies up to and including 60 Hz. This second edition of IEC 62271-203 cancels and replaces the first edition of IEC 62271-203, published in 2003, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - adopting the structure and the content to IEC 62271-1, - harmonisation with IEEE C37.122, - addition of the new Annex F and the new Annex G. This publication is to be read in conjunction with IEC 62271-1:2007.
Committee |
CLC/TC 17AC
|
DevelopmentNote |
Supersedes EN 60517. (03/2004) To be read in conjunction with EN 62271-1. (05/2012)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
IEC 62271-203:2011 | Identical |
NF EN 62271-203 : 2012 | Identical |
UNE-EN 62271-203:2013 | Identical |
NBN EN 62271-203 : 2012 | Identical |
NEN EN IEC 62271-203 : 2012 | Identical |
I.S. EN 62271-203:2012 | Identical |
PN EN 62271-203 : 2012 | Identical |
DIN EN 62271-203 : 2012 | Identical |
VDE 0671-203 : 2012 | Identical |
BS EN 62271-203:2012 | Identical |
CEI EN 62271-203 : 2013 | Identical |
BS EN IEC 80601-2-49:2019 | Identical |
UNE-EN 62271-205:2011 | High-voltage switchgear and controlgear -- Part 205: Compact switchgear assemblies for operation at rated voltages above 52 kV |
CEI EN 62271-207 : 2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
CEI EN 62271-204 : 2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGES ABOVE 52 KV |
BS EN 62271-200:2012 | High-voltage switchgear and controlgear AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
UNE-EN 60099-4:2016 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
BS EN 62271-209:2007 | High-voltage switchgear and controlgear Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV. Fluid-filled and extruded insulation cables. Fluid-filled and dry-type cable-terminations |
EN 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
EN 50052:2016 | High-voltage switchgear and controlgear - Gas-filled cast aluminium alloy enclosures |
EN 62271-209:2007 | High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations |
EN 62271-109:2009/A1:2013 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES (IEC 62271-109:2008/A1:2013) |
EN 62271-205:2008/corrigendum:2008 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
EN 62271-211:2014/AC:2017-09 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 211: DIRECT CONNECTION BETWEEN POWER TRANSFORMERS AND GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-211:2014/COR2:2017) |
CEI EN 62271-112 : 2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 112: ALTERNATING CURRENT HIGH-SPEED EARTHING SWITCHES FOR SECONDARY ARC EXTINCTION ON TRANSMISSION LINES |
UNE-EN 62271-204:2012 | High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV |
BS EN 62271-211:2014 | High-voltage switchgear and controlgear Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
15/30303100 DC : 0 | BS EN 50052 - CAST ALUMINIUM ALLOY ENCLOSURES FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR |
BS EN 50052:2016 | High-voltage switchgear and controlgear. Gas-filled cast aluminium alloy enclosures |
CEI EN 62271-209 : 2009 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 209: CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV - FLUID-FILLED AND EXTRUDED INSULATION CABLES - FLUID-FILLED AND DRY-TYPE CABLE-TERMINATIONS |
I.S. EN 62271-211:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 211: DIRECT CONNECTION BETWEEN POWER TRANSFORMERS AND GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV |
I.S. EN 62146-1:2014 | GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL |
BS EN 62271-100 : 2009 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS (IEC 62271-100:2008) |
CEI EN 60099-5 : 2014 | SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS |
CEI EN 60099-4 : 2015 | SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS |
EN 61936-1 : 2010 AMD 1 2014 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014) |
EN 62271-112:2013 | High-voltage switchgear and controlgear - Part 112: Alternating current high-speed earthing switches for secondary arc extinction on transmission lines |
I.S. EN 50052:2016 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - GAS-FILLED CAST ALUMINIUM ALLOY ENCLOSURES |
UNE-EN 62271-207:2012 | High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV |
17/30364387 DC : 0 | BS EN 50069 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - GAS-FILLED WELDED COMPOSITE ENCLOSURES OF CAST AND WROUGHT ALUMINIUM ALLOYS |
BS EN 60099-5:2013 | Surge arresters Selection and application recommendations |
CEI EN 50052 : 1998 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - GAS-FILLED CAST ALUMINIUM ALLOY ENCLOSURES |
PREN 50069 : DRAFT 2017 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - GAS-FILLED WELDED COMPOSITE ENCLOSURES OF CAST AND WROUGHT ALUMINIUM ALLOYS |
I.S. EN 61869-1:2009 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
I.S. EN 62271-207:2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-207:2012 (EQV)) |
BS EN 62146-1 : 2014 | GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL (IEC 62146-1:2013) |
I.S. EN 60099-4:2014 | SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS |
EN 62271-200:2012/AC:2015 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011) |
I.S. EN 62271-205:2008 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
I.S. EN 60099-5:2013 | SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS (IEC 60099-5:2013 (EQV)) |
UNE-EN 61869-1:2010 | Instrument transformers -- Part 1: General requirements |
EN IEC 60099-5:2018 | Surge arresters - Part 5: Selection and application recommendations |
I.S. EN 62271-112:2013 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 112: ALTERNATING CURRENT HIGH-SPEED EARTHING SWITCHES FOR SECONDARY ARC EXTINCTION ON TRANSMISSION LINES (IEC 62271-112:2013 (EQV)) |
PREN 50052 : DRAFT 2015 | CAST ALUMINIUM ALLOY ENCLOSURES FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR |
BS EN 62271-112:2013 | High-voltage switchgear and controlgear Alternating current high-speed earthing switches for secondary arc extinction on transmission lines |
BS EN 60099-9:2014 | Surge arresters Metal-oxide surge arresters without gaps for HVDC converter stations |
BS EN 62271-207:2012 | High-voltage switchgear and controlgear Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV |
I.S. EN 62271-209:2007 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 209: CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV - FLUID-FILLED AND EXTRUDED INSULATION CABLES - FLUID-FILLED AND DRY-TYPE CABLE-TERMINATIONS |
UNE-EN 50052:2017 | High-voltage switchgear and controlgear - Gas-filled cast aluminium alloy enclosures |
EN 62271-100 : 2009 AMD 2/COR 18 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS (IEC 62271-100:2008/A2:2017/COR1:2018) |
I.S. EN 62271-100:2009 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: ALTERNATING-CURRENT CIRCUIT-BREAKERS |
I.S. EN 62271-109:2009 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES (IEC 62271-109:2008 (EQV)) |
CEI EN 62271-205 : 2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
I.S. EN 61936-1:2010 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
BS EN 61936-1 : 2010 | POWER INSTALLATIONS EXCEEDING 1 KV A.C - PART 1: COMMON RULES |
UNE-EN 61936-1:2012 | Power installations exceeding 1 kV a.c. -- Part 1: Common rules |
EN 62271-204:2011 | High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV |
BS EN 61869-1:2009 | Instrument transformers General requirements |
17/30364380 DC : 0 | BS EN 50064 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - GAS-FILLED WROUGHT ALUMINIUM AND ALUMINIUM ALLOY ENCLOSURES |
BS EN 62271-205:2008 | High-voltage switchgear and controlgear Compact switchgear assemblies for rated voltages above 52 kV |
I.S. EN 62271-204:2011 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGE ABOVE 52 KV (IEC 62271-204:2011 (EQV)) |
BS EN 62271-204:2011 | High-voltage switchgear and controlgear Rigid gas-insulated transmission lines for rated voltage above 52 kV |
PREN 50064 : DRAFT 2017 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - GAS-FILLED WROUGHT ALUMINIUM AND ALUMINIUM ALLOY ENCLOSURES |
CEI EN 61869-1 : 2010 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
I.S. EN IEC 60099-5:2018 | SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS |
I.S. EN 60099-9:2014 | SURGE ARRESTERS - PART 9: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR HVDC CONVERTER STATIONS |
CEI EN 60099-9 : 2015 | SURGE ARRESTERS - PART 9: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR HVDC CONVERTER STATIONS |
BS EN 60099-4:2014 | Surge arresters Metal-oxide surge arresters without gaps for a.c. systems |
EN 62271-207:2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-207:2012) |
EN 62146-1:2014/A1:2016 | GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL (IEC 62146-1:2013/A1:2016) |
EN 61869-1:2009 | Instrument transformers - Part 1: General requirements |
EN 60099-9:2014 | Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations |
EN 60099-5:2013 | Surge arresters - Part 5: Selection and application recommendations |
IEC 60480:2004 | Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use |
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
EN 60044-2:1999/A2:2003 | INSTRUMENT TRANSFORMERS - PART 2: INDUCTIVE VOLTAGE TRANSFORMERS |
IEC 61672-2:2013+AMD1:2017 CSV | Electroacoustics - Sound level meters - Part 2: Pattern evaluation tests |
IEC 60038:2009 | IEC standard voltages |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
EN 50052:2016 | High-voltage switchgear and controlgear - Gas-filled cast aluminium alloy enclosures |
EN 60376:2005 | Specification of technical grade sulfur hexafluoride (SF6) for use in electrical equipment |
CLC/TR 62271-303:2009 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 303: USE AND HANDLING OF SULPHUR HEXAFLUORIDE (SF[6]) |
EN 61264:1998/corrigendum:2000 | CERAMIC PRESSURIZED HOLLOW INSULATORS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR |
IEC 62271-207:2012 | High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV |
IEC 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V |
EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
EN ISO 3231:1997 | Paints and varnishes - Determination of resistance to humid atmospheres containing sulfur dioxide (ISO 3231:1993) |
IEEE 1416 : 1998 | INTERFACE OF NEW GAS INSULATED EQUIPMENT IN EXISTING GAS INSULATED SUBSTATIONS |
IEC 62067:2011 RLV | Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements |
IEC 60050-471:2007 | International Electrotechnical Vocabulary (IEV) - Part 471: Insulators |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 60044-2:1997+AMD1:2000+AMD2:2002 CSV | Instrument transformers - Part 2 : Inductive voltage transformers |
IEC TS 60815-2:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems |
EN 62271-102:2002/AC:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001/A2:2013) |
IEC 60068-2-11:1981 | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist |
EN 60480:2004 | Guidelines for the checking and treatment of sulphur hexafluoride (SF6) taken from electrical equipment and specification for its re-use |
IEC 62271-209:2007 | High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations |
IEC TR 62271-300:2006 | High-voltage switchgear and controlgear - Part 300: Seismic qualification of alternating current circuit-breakers |
IEC 60376:2005 | Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment |
EN 50064 : 1989 COR 2007 | WROUGHT ALUMINIUM AND ALUMINIUM ALLOY ENCLOSURES FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
IEEE C37.122.1-2014 | IEEE Guide for Gas-Insulated Substations Rated Above 52 kV |
IEC 60044-1:1996+AMD1:2000+AMD2:2002 CSV | Instrument transformers - Part 1: Current transformers |
IEC 61462:2007 | Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEEE C37.24-2003 | IEEE Guide for Evaluating the Effect of Solar Radiation on Outdoor Metal-Enclosed Switchgear |
EN 62271-209:2007 | High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations |
IEC TR 62271-303:2008 | High-voltage switchgear and controlgear - Part 303: Use and handling of sulphur hexafluoride (SF<sub>6</sub>) |
IEC 60141-1:1993 | Tests on oil-filled and gas-pressure cables and their accessories - Part 1: Oil-filled, paper or polypropylene paper laminate insulated, metal-sheathed cables and accessories for alternating voltages up to and including 500 kV |
EN 60044-1:1999/A2:2003 | INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS |
EN 60068-2-11:1999 | Environmental testing - Part 2: Tests - Test Ka: Salt mist |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
EN 50068 : 1991 COR 2007 | WROUGHT STEEL ENCLOSURES FOR GAS FILLED HIGH VOLTAGE SWITCHGEAR AND CONTROLGEAR |
IEC TS 60815-1:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles |
IEC TS 60815-3:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems |
IEC 62271-102:2001+AMD1:2011+AMD2:2013 CSV | High-voltage switchgear and controlgear - Part 102: Alternatingcurrent disconnectors and earthing switches |
ISO 3231:1993 | Paints and varnishes — Determination of resistance to humid atmospheres containing sulfur dioxide |
EN 50089 : 92 AMD 1 94 | SPECIFICATION FOR CAST RESIN PARTITIONS FOR METAL-ENCLOSED GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.