EN 62271-106:2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters
07-13-2021
10-07-2011
FOREWORD
1 General
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
5 Design and construction
6 Type tests
7 Routine tests
8 Guide to the selection of contactors and
motor-starters for service
9 Information to be given with enquiries,
tenders and orders
10 Transport, storage, installation, operation
and maintenance
11 Safety
12 Influence of the product on the environment
Annex A (normative) - Records and reports of
type tests for making, breaking and
short-time current performance
Annex B (normative) - Tolerances
Annex C (informative) - List of symbols and
abbreviations
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 62271-106:2011 is applicable to a.c. contactors and/or contactor-based controllers and motor-starters designed for indoor installation and operation at frequencies up to and including 60 Hz on systems having voltages above 1 000 V but not exceeding 24 000 V. It is applicable only to three-pole devices for use in three-phase systems, and single-pole devices for use in single-phase systems. Two-pole contactors and starters for use in single-phase systems are subject to agreement between manufacturer and user. This standard cancels and replaces the second edition of IEC 60470 published in 1999. It constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60470:1999: - Scope and object: The voltage range covered by the standard was expanded from 12 kV to 24 kV. Overload relay calibration and testing is not covered by this standard. - 3 Terms and definitions: Added definitions for capacitor switching classes. - 4.1 Rated voltage: Added 15, 17,5 and 24 kV as standard voltage values. - 4.109.2 Starting duty of reduced-voltage starters: Added ratings for autotransformer and reactor starters (was in the testing section). - 4.112 Rated capacitive switching currents: Added capacitor switching current ratings. - 5.101 Protective relays: Removed the requirements for overload relays. This section is obsolete since there are only a few MV starters fitted with thermal overload relays and electronic relays have their own standards. - 6.2.5 Application of the test voltage and test conditions (former 6.2.2 b)): Changed wording of requirement for impulse across the open gap of vacuum contactors. - 6.4.2 Auxiliary circuits: The requirement for resistance checks of auxiliary circuits was deleted. - 6.5.5.104 Temperature rise of the auto transformer or reactor for two step auto transformer or reactor starters: Reworded to transfer ratings to subclause 4.109.2. - 6.102.9 Condition following making and breaking tests: Gave specific direction as to what the tolerance should be based on where the resistance was to be checked. - 6.104 Short-circuit current making and breaking tests: Clarified test conditions for short-circuit testing. - 6.109 Capacitive current switching tests: Added capacitive current switching tests. - Annex B: Added Table B.1 - Tolerances on test quantities for type test.
Committee |
CLC/TC 17AC
|
DevelopmentNote |
Supersedes EN 60470. To be read in conjunction with EN 62271-1. (10/2011) Supersedes UNE EN 60470. (09/2014)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN 62271-106:2012 | Identical |
UNE-EN 62271-106:2011 | Identical |
BS EN 62271-106:2011 | Identical |
NF EN 62271-106 : 2012 | Identical |
DIN EN 62271-106 : 2012 | Identical |
VDE 0671-106 : 2012 | Identical |
I.S. EN 62271-106:2011 | Identical |
PN EN 62271-106 : 2011 | Identical |
IEC 62271-106:2011 | Identical |
NBN EN 62271-106 : 2011 | Identical |
I.S. EN IEC 62271-110:2018 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 110: INDUCTIVE LOAD SWITCHING |
EN 62271-201:2014 | High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
CEI EN 62271-201 : 2015 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
EN IEC 62271-110:2018/AC:2018-03 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 110: INDUCTIVE LOAD SWITCHING (IEC 62271-110:2017/COR1:2017, IEC 62271-110:2017/COR2:2018 |
UNE-EN 62271-201:2015 | High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
BS EN 62271-201:2014 | High-voltage switchgear and controlgear AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
I.S. EN 62271-201:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 62271-110:2017 | High-voltage switchgear and controlgear - Part 110: Inductive load switching |
IEC 61812-1:2011 | Time relays for industrial and residential use - Part 1: Requirements and tests |
EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 60644:2009 | Specification for high-voltage fuse-links for motor circuit applications |
EN 62271-102:2002/AC:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001/A2:2013) |
IEC 60282-1:2009+AMD1:2014 CSV | High-voltage fuses - Part 1: Current-limiting fuses |
IEC 60050-442:1998 | International Electrotechnical Vocabulary (IEV) - Part 442: Electrical accessories |
IEC 62271-103:2011 | High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV |
IEC 61230:2008 | Live working - Portable equipment for earthing or earthing and short-circuiting |
IEC 60255-8:1990 | Electrical relays - Part 8: Thermal electrical relays |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
EN 60282-1:2009/A1:2014 | HIGH-VOLTAGE FUSES - PART 1: CURRENT-LIMITING FUSES (IEC 60282-1:2009) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
EN 60644:2009 | Specification for high-voltage fuse-links for motor circuit application |
EN 62271-200:2012/AC:2015 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011) |
IEC 62271-102:2001+AMD1:2011+AMD2:2013 CSV | High-voltage switchgear and controlgear - Part 102: Alternatingcurrent disconnectors and earthing switches |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.