• Shopping Cart
    There are no items in your cart

EN 62153-4-7:2016/AC:2016-05

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE Z[T] AND SCREENING ATTENUATION A[S] OR COUPLING ATTENUATION A[C] OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD (IEC 62153-4-7:2015/COR1:2016)

Superseded date

09-24-2021

Superseded by

EN IEC 62153-4-7:2021

Published date

01-12-2013

Sorry this product is not available in your region.

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Physical background
5 Principle of the test methods
6 Test procedure
7 Sample preparation
8 Measurement of transfer impedance
9 Screening attenuation
10 Coupling attenuation
Annex A (normative) - Determination of the impedance of
        the inner circuit
Annex B (informative) - Example of a self-made impedance
        matching adapter
Annex C (informative) - Measurements of the screening effectiveness
        of connectors and cable assemblies
Annex D (informative) - Influence of contact resistances
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

Describes the triaxial method which is suitable to determine the surface transfer impedance and/or screening attenuation and coupling attenuation of mated screened connectors (including the connection between cable and connector) and cable assemblies.

Committee
SC 46XA
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

BS EN 60966-2-5:2017 Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 1 000 MHz, IEC 61169-2 connectors
CEI EN 60966-2-6 : 2010 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-6: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-24 CONNECTORS
EN 60966-2-5:2017 Radio frequency and coaxial cable assemblies - Part 2-5: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 1 000 MHz, IEC 61169-2 connectors
EN 60966-2-4:2016 Radio Frequency and coaxial cable assemblies - Part 2-4: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-2 connectors
I.S. EN 60966-2-6:2017 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-6: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-24 CONNECTORS
BS EN 60966-2-6:2017 Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 3 000 MHz, IEC 61169-24 connectors
BS EN 60966-2-7:2016 Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 3 000 MHz, IEC 61169-47 connectors
BS EN 60966-2-4:2009 Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 3 000 MHz, IEC 61169-2 connectors
CEI EN 60966-2-4 : 2010 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-4: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-2 CONNECTORS
I.S. EN 60966-2-5:2017 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-5: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 1000 MHZ, IEC 61169-2 CONNECTORS
I.S. EN 60966-2-4:2016 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-4: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-2 CONNECTORS
I.S. EN 60966-2-7:2016 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-7: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-47 CONNECTORS
CEI EN 60966-2-5 : 2010 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-5: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 1000 MHZ, IEC 61169-2 CONNECTORS
EN 60966-2-6:2017 Radio frequency and coaxial cable assemblies - Part 2-6: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-24 connectors
EN 60966-2-7:2016 Radio frequency and coaxial cable assemblies - Part 2-7: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-47 connectors

IEC 62153-4-3:2013 Metallic communication cable test methods - Part 4-3: Electromagnetic compatibility (EMC) - Surface transfer impedance - Triaxial method
IEC 62153-4-15:2015 Metallic communication cable test methods - Part 4-15: Electromagnetic compatibility (EMC) - Test method for measuring transfer impedance and screening attenuation - or coupling attenuation with triaxial cell
IEC 62153-4-4:2015 Metallic communication cable test methods - Part 4-4: Electromagnetic compatibility (EMC) - Test method for measuring of the screening attenuation as up to and above 3 GHz, triaxial method
IEC 62153-4-8:2006 Metallic communication cable test methods - Part 4-8: Electromagnetic compatibility (EMC) - Capacitive coupling admittance
IEC TS 62153-4-1:2014 Metallic communication cable test methods - Part 4-1: Electromagnetic compatibility (EMC) - Introduction to electromagnetic screening measurements
IEC 62153-4-9:2008 Metallic communication cable test methods - Part 4-9: Electromagnetic compatibility (EMC) - Coupling attenuation of screened balanced cables, triaxial method
IEC 62153-4-10:2015 Metallic communication cable test methods - Part 4-10: Electromagnetic compatibility (EMC) - Transfer impedance and screening attenuation of feed-throughs and electromagnetic gaskets - Double coaxial test method

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.