EN 61966-3:2000
Current
The latest, up-to-date edition.
Multimedia systems and equipment - Colour measurement and management - Part 3: Equipment using cathode ray tubes
04-03-2000
1 Scope
2 Normative references
3 Terms and definitions
4 Letters and symbols
5 Conditions
5.1 Environmental conditions
5.2 Conditions for measurements
5.3 Input digital data
6 Measurement equipment
6.1 Spectroradiometer
6.2 Colorimeter
7 Spectral characteristics and intensity of the
primaries and white stimuli
7.1 Characteristics to be measured
7.2 Measurement conditions
7.3 Method of measurement
7.4 Presentation of results
8 Basic colorimetric characteristics
8.1 Characteristics to be measured
8.2 Method of measurement
8.3 Presentation of results
9 Tone characteristics
9.1 Characteristics to be measured
9.2 Measurement conditions
9.3 Method of measurement
9.4 Presentation of results
10 Inter-channel dependency
10.1 Characteristics to be measured
10.2 Measurement conditions
10.3 Method of measurement
10.4 Presentation of results
11 Spatial non-uniformity
11.1 Characteristics to be measured
11.2 Measurement conditions
11.3 Method of measurement
11.4 Presentation of results
12 Temporal stability
12.1 Short-term stability
12.1.1 Characteristics to be measured
12.1.2 Measurement conditions
12.1.3 Method of measurement
12.1.4 Presentation of results
12.2 Mid-term instability
12.2.1 Characteristics to be measured
12.2.2 Measurement conditions
12.2.3 Method of measurement
12.2.4 Presentation of results
13 Surface reflection
13.1 Characteristics to be measured
13.2 Measurement conditions
13.3 Method of measurement
13.4 Presentation of results
14 Internal flare
14.1 Characteristics to be measured
14.2 Measurement conditions
14.3 Method of measurement
14.4 Presentation of results
Figure 1 - Equipment arrangement for non-contact measurements
Figure 2 - Equipment arrangement for contact measurements
Figure 3 - Size of a colour patch
Figure 4 - An example of the spectral radiance distributions;
r(l), g(l), and b(l)
Figure 5 - Measured points and estimated non-linear curves on
linear and log-log scales
Figure 6 - Measurement points for spatial non-uniformity
Figure 7 - Example plots for short-term stability
Figure 8 - Example plots for mid-term stability
Figure 9 - Equipment arrangement
Table 1 - Input data for peak primaries and white
Table 2 - Example of reporting form for colours in maximum
excitations
Table 3 - Example of reporting form
Table 4 - An example of calculated parameters and
normalisation factors
Table 5 - An example set of basic data for tone
characteristics
Table 6 - Digital inputs to generate colour patches for
measurement of inter-channel dependency
Table 7 - Example of normalised tristimulus values (the
matrix A)
Table 8 - Example of reporting form
Table 9 - Example of reporting form
Table 10 - An example of colorimetric change
Table A.1 - Types of instruments
Annex A (normative) Required colorimetric instruments
Annex B (normative) Alternative method of measurement of
surface reflection
Annex C (informative) Evaluation of effect of external light
source
Annex D (informative) Evaluation of internal and external
flare
Bibliography
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Deals with equipment using cathode ray tubes (CRT) to display colour images in multimedia applications. Defines input test signals, measurement conditions and methods of measurement, to make possible the colour management and comprehensive comparison of the results of the measurements.
Committee |
CLC/TC 100X
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
PN EN 61966-3 : 2003 | Identical |
I.S. EN 61966-3:2000 | Identical |
NF EN 61966-3 : 2000 | Identical |
CEI EN 61966-3 : 2001 | Identical |
DIN EN 61966-3:2000-10 | Identical |
BS EN 61966-3:2000 | Identical |
SN EN 61966-3 : 2000 | Identical |
UNE-EN 61966-3:2001 | Identical |
NEN EN IEC 61966-3 : 2000 | Identical |
NBN EN 61966-3 : 2001 | Identical |
IEC 61966-3:2000 | Identical |
BS EN 61966-5:2009 | Multimedia systems and equipment. Colour measurement and management Equipment using plasma display panels |
CEI EN 61966-5 : 2012 | MULTIMEDIA SYSTEMS AND EQUIPMENT - COLOUR MEASUREMENT AND MANAGEMENT - PART 5: EQUIPMENT USING PLASMA DISPLAY PANELS |
UNE-EN 61966-5:2010 | Multimedia systems and equipment - Colour measurement and management -- Part 5: Equipment using plasma display panels |
EN 61966-5:2009 | Multimedia systems and equipment - Colour measurement and management - Part 5: Equipment using plasma display panels |
IEC 60050-845:1987 | International Electrotechnical Vocabulary (IEV) - Part 845: Lighting |
ISO/CIE 10527:1991 | CIE standard colorimetric observers |
ISO 5-4:2009 | Photography and graphic technology Density measurements Part 4: Geometric conditions for reflection density |
ISO/CIE 10526:1999 | CIE standard illuminants for colorimetry |
ISO 9241-8:1997 | Ergonomic requirements for office work with visual display terminals (VDTs) Part 8: Requirements for displayed colours |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.