EN 61952:2008
Current
The latest, up-to-date edition.
Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
10-15-2008
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviations
5 Identification
6 Environmental conditions
7 Transport, storage and installation
8 Tolerances
9 Classification of tests
9.1 Design tests
9.2 Type tests
9.3 Sample tests
9.4 Routine tests
10 Design tests
10.1 General
10.2 Test specimens for IEC 62217
10.2.1 Tests on interfaces and connections of
end fittings
10.2.2 Tracking and erosion test
10.2.3 Tests on core material
10.3 Product specific pre-stressing for IEC 62217
tests on interfaces and connections of end fittings
10.3.1 Thermal-mechanical pre-stressing
10.4 Assembled core load tests
10.4.1 Test for the verification of the maximum
design cantilever load (MDCL)
10.4.2 Tensile load test
11 Type tests
11.1 Electrical tests
11.1.1 Vertical mounting arrangement
11.1.2 Horizontal mounting arrangement
11.2 Mechanical tests
11.2.1 Cantilever failing load test
12 Sample tests
12.1 General rules
12.2 Verification of dimensions (E1 + E2)
12.3 Galvanizing test (E1 + E2)
12.4 Verification of the SCL (E1)
12.4.1 Test procedure
12.4.2 Acceptance criteria
12.5 Re-testing procedure
13 Routine tests
13.1 Tensile load test
13.2 Visual examination
Annex A (informative) - Notes on the mechanical loads
and tests
Annex B (informative) - Determination of the equivalent
bending moment caused by combined loads
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Bibliography
IEC 61952:2008 applies to composite line post insulators consisting of a load-bearing, cylindrical, insulating solid core made up of fibres - usually glass - in a resin-based matrix, a housing (outside the insulating core) made of elastomer material (e.g. silicone or ethylene-propylene) and end fittings permanently attached to the insulating core.
Committee |
SR 36
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NF EN 61952 : 2008 | Identical |
IEC 61952:2008 | Identical |
NBN EN 61952 : 2009 | Identical |
NEN EN IEC 61952 : 2008 | Identical |
I.S. EN 61952:2008 | Identical |
PN EN 61952 : 2010 | Identical |
SN EN 61952 : 2003 | Identical |
VDE 0441-200 : 2009 | Identical |
DIN EN 61952 : 2009 | Identical |
BS EN 61952:2008 | Identical |
UNE-EN 61952:2010 | Identical |
CEI EN 61952 : 2009 | Identical |
BS EN IEC 60794-2-30:2019 | Identical |
UNE-EN 50341-1:2017 | Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications |
PREN 50119 : DRAFT 2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
BS EN 50341-1:2012 | Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications |
EN 50151 : 2003 COR 2010 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIAL REQUIREMENTS FOR COMPOSITE INSULATORS |
I.S. EN 50151:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIAL REQUIREMENTS FOR COMPOSITE INSULATORS |
BS EN 50119 : 2009 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
17/30341013 DC : DRAFT AUG 2017 | BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
BS EN 62621 : 2016 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS (IEC 62621:2011) |
EN 50341-1:2012 | Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications |
I.S. EN 50119:2009 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
NF EN 50119 : 2010 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
I.S. EN 50341-1:2012 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
CEI EN 50341-1 : 2013 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
12/30260570 DC : 0 | BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
BS EN 50151:2003 | Railway applications. Fixed installations. Electric traction. Special requirements for composite insulators |
I.S. EN 50119:2020 | Railway applications - Fixed installations - Electric traction overhead contact lines |
UNE-EN 62621:2016 | Railway applications - Fixed installations - Electric traction - Specific requirements for composite insulators used for overhead contact line systems |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
PREN 50341-1 : DRAFT 2012 | OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS |
I.S. EN 62621:2016 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS |
EN 62621:2016/A1:2016 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS |
IEC 61467:2008 | Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests |
IEC 60050-471:2007 | International Electrotechnical Vocabulary (IEV) - Part 471: Insulators |
IEC 62217:2012 | Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria |
IEC 60383-1:1993 | Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria |
EN 61462:2007 | Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations |
EN 60383-1:1996/A11:1999 | INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1 KV - CERAMIC OR GLASS INSULATOR UNITS FOR A.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA |
ISO 3452:1984 | Non-destructive testing — Penetrant inspection — General principles |
EN 60507:2014 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
IEC 61462:2007 | Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations |
IEC GUIDE 111:2004 | Electrical high-voltage equipment in high-voltage substations - Common recommendations for product standards |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
EN 62217:2013 | Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria |
IEC 60383-2:1993 | Insulators for overhead lines with a nominal voltage above 1000 V - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria |
EN 60383-2:1995 | Insulators for overhead lines with a nominal voltage above 1 kV - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.