EN 61784-5-3:2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Industrial communication networks - Profiles - Part 5-3: Installation of fieldbuses - Installation profiles for CPF 3
02-12-2022
12-13-2013
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and abbreviated terms
4 CPF 3: Overview of installation profiles
5 Installation profile conventions
6 Conformance to installation profiles
Annex A (normative) - CP 3/1 (PROFIBUS) specific installation
profile
Annex B (normative) - CP 3/2 (PROFIBUS) specific installation
profile
Annex C (normative) - CP 3/3, CP 3/4, CP 3/5, CP 3/6 (PROFINET)
specific installation profile
Annex ZA (normative) - Normative references to international
Publications with their corresponding European
publications
Bibliography
IEC 61784-5-3:2013 specifies the installation profiles for CPF 3 (PROFIBUS/PROFINET). Each CP installation profile is specified in a separate annex of this standard. The IEC 61784 series is produced to facilitate the use of communication networks in industrial control systems. This third edition cancels and replaces the second edition published in 2010 and constitutes a technical revision. It includes the following changes: - an addition of 4-pair cabling, - an addition of the connector M12 X-Coding, - an addition of the definition of end-to-end links, - a revision of Table C.17 and - a formula for the NEXT limits of end-to-end links. This standard is to be used in conjunction with IEC 61918:2013.
Committee |
CLC/TC 65X
|
DevelopmentNote |
To be read in conjunction with EN 61918. (08/2008)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
CEI EN 61784-5-3 : 2014 | Identical |
NBN EN 61784-5-3 : 2014 | Identical |
NEN EN IEC 61784-5-3 : 2013 | Identical |
NF EN 61784-5-3 : 2014 | Identical |
I.S. EN 61784-5-3:2013 | Identical |
DIN EN 61784-5-3 : 2015 | Identical |
OVE/ONORM EN 61784-5-3 : 2015 | Identical |
IEC 61784-5-3:2013 | Identical |
VDE 0800-500-3 : 2015 | Identical |
PN EN 61784-5-3 : 2014 | Identical |
UNE-EN 61784-5-3:2013 | Identical |
UNE-EN 61784-5-3:2008 | Identical |
BS EN 61784-5-3:2013 | Identical |
EN 61784-3-3:2017 | Industrial communication networks - Profiles - Part 3-3: Functional safety fieldbuses - Additional specifications for CPF 3 |
EN 50174-2 : 2009 AMD 2 2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
I.S. EN 61784-3-3:2017 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3-3: FUNCTIONAL SAFETY FIELDBUSES - ADDITIONAL SPECIFICATIONS FOR CPF 3 |
CEI EN 61784-3-3 : 2012 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3-3: FUNCTIONAL SAFETY FIELDBUSES - ADDITIONAL SPECIFICATIONS FOR CPF 3 |
I.S. EN 50174-2:2009 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
EN 61784-2:2014 | Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 |
BS EN 61784-3-3:2017 | Industrial communication networks. Profiles Functional safety fieldbuses. Additional specifications for CPF 3 |
CEI EN 61784-2 : 2016 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 2: ADDITIONAL FIELDBUS PROFILES FOR REAL-TIME NETWORKS BASED ON ISO/IEC 8802-3 |
BS EN 61784-2:2014 | Industrial communication networks. Profiles Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 |
I.S. EN 61784-2:2014 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 2: ADDITIONAL FIELDBUS PROFILES FOR REAL-TIME NETWORKS BASED ON ISO/IEC 8802-3 |
BS EN 50174-2 : 2009 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
IEC 60793-2-10:2017 | Optical fibres - Part 2-10: Product specifications - Sectional specification for category A1 multimode fibres |
IEC 60512-6-3:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-3: Dynamic stress tests - Test 6c: Shock |
EN 50020:2002 | Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i' |
IEC 61076-2-107:2010 | Connectors for electronic equipment - Product requirements - Part 2-107: Detail specification for circular hybrid connectors M12 with electrical and fibre-optic contacts with screw locking |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 61918:2013 | Industrial communication networks - Installation of communication networks in industrial premises |
IEC 60079-27:2008 | Explosive atmospheres - Part 27: Fieldbus intrinsically safe concept (FISCO) |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEEE 802.3AH : 2004 | IEEE STANDARD FOR INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - CARRIER SENSE MULTIPLE ACCESS WITH COLLISION DETECTION (CSMA/CD) ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS - AMENDMENT: MEDIA ACCESS CONTROL PARAMETERS, PHYSICAL LAYERS, AND MANAGEMENT PARAMETERS FOR SUBSCRIBER ACCESS |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
IEC 60793-2-50:2015 | Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres |
EN 61918:2013/AC:2014 | INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES (IEC 61918:2013, MODIFIED) |
IEC 61156-5:2009+AMD1:2012 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 5: Symmetrical pair/quad cables withtransmission characteristics up to 1 000 MHz - Horizontal floorwiring - Sectional specification |
TIA 485 : A1998(R2012) | ELECTRICAL CHARACTERISTICS OF GENERATORS AND RECEIVERS FOR USE IN BALANCED DIGITAL MULTIPOINT SYSTEMS |
IEC 60512-6-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-4: Dynamic stress tests - Test 6d: Vibration (sinusoidal) |
IEC 61754-24-11:2009 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 24-11: Type SC-RJ connectors with protective housings based on IEC 61076-3-117 |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.