1 Scope
2 Normative references
3 Terms and definitions
3.1 General definitions
3.2 Definitions related to uncertainty and performance
3.3 Definitions related to electric phenomena
3.4 Definitions related to measurement techniques
3.5 Notations
4 Requirements
4.1 General requirements
4.2 PMD general architecture
4.3 Classification of PMD
4.4 List of applicable performance classes
4.5 Operating and reference conditions for PMD
4.6 Start-up conditions
4.7 Requirements for PMD functions (except PMD-A)
4.8 Requirements for PMD-A functions
4.9 General mechanical requirements
4.10 Safety requirements
4.11 Analog outputs
5 Marking and operating instructions
5.1 Marking
5.2 Operating and installation instructions
6 Tests
6.1 Type tests of PMD
6.2 Type tests of PMD-A
6.3 Routine tests
Annex A (informative) - Definitions of electrical parameters
Annex B (normative) - Definitions of minimum, maximum, peak
and demand values
Annex C (informative) - Intrinsic uncertainty, operating
uncertainty, and overall system uncertainty
Annex D (informative) - Recommended sensor classes for the
different kinds of PMD
Annex E (normative) - Requirements applicable to PMD and to
PMD-A
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Annex ZZ (informative) - Coverage of Essential Requirements of
EC Directives
Specifies requirements for combined performance measuring and monitoring devices that measure and monitor the electrical parameters within electrical distribution systems. These requirements also define the performance, in single and three-phase a.c. or d.c. systems having rated voltages up to 1 000 V a.c. or up to 1 500 V d.c. These devices are fixed installed or portable. They are intended to be used indoors and/or outdoors. This standard is not applicable for: - electricity metering equipment that complies with IEC 62053-21, IEC 62053-22 and IEC 62053-23. Nevertheless, uncertainties defined in this standard for active and reactive energy measurement are derived from those defined in the IEC 62053 standards series. - simple remote relays or simple monitoring relays. This standard is intended to be used in conjunction with IEC 61557-1 (unless otherwise specified), which specifies the general requirements for measuring and monitoring equipment, as required in IEC 60364-6. The standard does not include the measurement and monitoring of electrical parameters defined in Parts 2 to 9 of IEC 61557 or in IEC 62020. Combined performance measuring and monitoring devices (PMD), as defined in this standard, give additional safety information, which aids the verification of the installation and enhances the performance of the distribution systems. For instance, those devices help to check if the level of harmonics is still compliant with the wiring systems as required in IEC 60364-5-52. The combined performance measuring and monitoring devices (PMD) for electrical parameters described in this standard are used for general industrial and commercial applications. A PMD-A is a specific PMD complying with requirements of IEC 61000-4-30 class A, which may be used in 'power quality assessment' applications.
Committee |
CLC/TC 85X
|
DevelopmentNote |
To be read in conjunction with EN 61557-1. (07/2008)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
OVE/ONORM EN 61557-12 : 2009 | Identical |
PN EN 61557-12 : 2008 | Identical |
IEC 61557-12:2007 | Identical |
CEI EN 61557-12 : 2013 | Identical |
VDE 0413-12 : 2008 | Identical |
UNE-EN 61557-12:2010 | Identical |
NEN EN IEC 61557-12 : 2008 | Identical |
BS EN 61557-12:2008 | Identical |
NBN EN 61557-12 : 2008 | Identical |
DIN EN 61557-12 : 2008-12 | Identical |
NF EN 61557-12 : 2008 | Identical |
I.S. EN 61557-12:2008 | Identical |
I.S. EN 61724-1:2017 | PHOTOVOLTAIC SYSTEM PERFORMANCE - PART 1: MONITORING |
EN 60688:2013 | Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals |
EN 61724-1:2017 | Photovoltaic system performance - Part 1: Monitoring |
CEI EN 61724-1 : 1ED 2017 | PHOTOVOLTAIC SYSTEM PERFORMANCE - PART 1: MONITORING |
EN 303 446-2 : 1.1.0 DRAFT | ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR COMBINED AND/OR INTEGRATED RADIO AND NON-RADIO EQUIPMENT; PART 2: SPECIFIC CONDITIONS FOR EQUIPMENT INTENDED TO BE USED IN INDUSTRIAL LOCATIONS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.1(B) OF DIRECTIVE 2014/53/EU |
UNE-HD 60364-8-1:2015 | Low-voltage electrical installations - Part 8-1: Energy efficiency |
HD 60364-8-1:2015 | Low-voltage electrical installations - Part 8-1: Energy efficiency |
BS EN 60688:2013 | Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals |
UNE-EN 62974-1:2018 | Monitoring and measuring systems used for data collection, gathering and analysis - Part 1: Device requirements |
S.R. HD 60364-8-1:2015 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 8-1: ENERGY EFFICIENCY |
UNE-EN 60688:2013 | Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals |
I.S. EN 60688:2013 | ELECTRICAL MEASURING TRANSDUCERS FOR CONVERTING A.C. AND D.C. ELECTRICAL QUANTITIES TO ANALOGUE OR DIGITAL SIGNALS (IEC 60688:2012 (EQV)) |
EN 62053-31:1998 | Electricity metering equipment (a.c.) - Particular requirements - Part 31: Pulse output devices for electromechanical and electronic meters (two wires only) |
IEC 60050-131:2002 | International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory |
IEC 60044-7:1999 | Instrument transformers - Part 7: Electronic voltage transformers |
EN 61000-4-30:2015/AC:2017-01 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS (IEC 61000-4-30:2015/COR1:2016) |
IEC 62053-23:2003+AMD1:2016 CSV | Electricity metering equipment (a.c.) - Particular requirements -Part 23: Static meters for reactive energy (classes 2 and 3) |
IEC 62053-21:2003+AMD1:2016 CSV | Electricity metering equipment (a.c.) - Particular requirements - Part 21: Static meters for active energy (classes 1 and 2) |
IEC 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60050-601:1985 | International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60044-2:1997+AMD1:2000+AMD2:2002 CSV | Instrument transformers - Part 2 : Inductive voltage transformers |
2004/108/EC : 2004 | DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC |
IEC 62052-11:2003+AMD1:2016 CSV | Electricity metering equipment (a.c.) - General requirements, tests and test conditions - Part 11: Metering equipment |
IEC 61010-2-030:2017 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for equipment having testing or measuring circuits |
IEC 61557-1:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements |
IEC 62053-31:1998 | Electricity metering equipment (a.c.) - Particular requirements - Part 31: Pulse output devices for electromechanical and electronic meters (two wires only) |
EN 61326-1:2013 | Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
IEC 60364-6:2016 | Low voltage electrical installations - Part 6: Verification |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60044-1:1996+AMD1:2000+AMD2:2002 CSV | Instrument transformers - Part 1: Current transformers |
IEC 61000-4-15:2010 | Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 61557-1:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements |
IEC 61000-4-7:2002+AMD1:2008 CSV | Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto |
IEC 62053-22:2003+AMD1:2016 CSV | Electricity metering equipment (a.c.) - Particular Requirements - Part 22: Static meters for active energy (classes 0,2 S and 0,5 S) |
IEC 60359:2001 | Electrical and electronic measurement equipment - Expression of performance |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 61010-1:2010 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 60050-551-20:2001 | International Electrotechnical Vocabulary (IEV) - Part 551-20: Power electronics - Harmonic analysis |
IEC 60050-300:2001 | International Electrotechnical Vocabulary (IEV) - Part 300: Electrical and electronic measurements and measuring instruments - Part 311: General terms relating to measurements - Part 312: General terms relating to electrical measurements - Part 313: Types of electrical measuring instruments - Part 314: Specific terms according to the type of instrument |
EN 61000-4-15:2011 | Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications |
IEC 60364-5-52:2009 | Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.