EN 61462:2007
Current
The latest, up-to-date edition.
Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations
10-19-2007
FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 Relationships of mechanical loads
4.1 Loads from outside the insulator
4.2 Pressures
5 Marking
6 Classification of tests
6.1 Design tests
6.2 Type tests
6.3 Sample tests
6.4 Routine tests
7 Design tests
7.1 General
7.2 Tests on interfaces and connections of end fittings
7.3 Tests on shed and housing material
7.4 Tests on the tube material
8 Type tests (only mechanical tests)
8.1 General
8.2 Test specimens
8.3 Preparation of the test specimen
8.4 Internal pressure test
8.5 Bending test
9 Sample tests
9.1 Selection and number of insulators
9.2 Testing
9.3 Verification of dimensions
9.4 Mechanical tests
9.5 Galvanizing test
9.6 Check of the interface between end fittings and
the housing
9.7 Re-test procedure
10 Routine tests
10.1 General
10.2 Visual examination
10.3 Routine pressure test
10.4 Routine mechanical test
10.5 Routine tightness test
11 Documentation
Annex A (normative) - Tolerances of form and position
Annex B (informative) - General recommendations for design
and construction
Annex C (informative) - Principles of damage limit and use of
reversible and irreversible strain caused
by internal pressure and/or bending loads
on composite hollow insulator tubes
Annex ZA (normative) - Normative references to international
publications with their corresponding
European publications
Bibliography
This International Standard applies to composite hollow insulators consisting of a load-bearing insulating tube made of resin impregnated fibres, a housing (outside the insulating tube) made of elastomeric material (for example silicone or ethylene-propylene) and metal fixing devices at the ends of the insulating tube. The object of this standard is: To define the terms used; to prescribe test methods; and to prescribe acceptance criteria.
Committee |
CLC/SR 36
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
DS EN 61462 : 2007 | Identical |
NF EN 61462 : 2008 | Identical |
IEC 61462:2007 | Identical |
PN EN 61462 : 2009 | Identical |
UNE-EN 61462:2008 | Identical |
VDE 0441-102 : 2008 | Identical |
NBN EN 61462 : 2008 | Identical |
NEN EN IEC 61462 : 2007 | Identical |
DIN EN 61462 : 2008 | Identical |
BS EN 61462:2007 | Identical |
CEI EN 61462 : 2008 | Identical |
I.S. EN 61462:2007 | Identical |
UNE-EN 62271-205:2011 | High-voltage switchgear and controlgear -- Part 205: Compact switchgear assemblies for operation at rated voltages above 52 kV |
I.S. EN 60358-1:2012 | COUPLING CAPACITORS AND CAPACITOR DIVIDERS - PART 1: GENERAL RULES (IEC 60358-1:2012 (EQV)) |
BS EN 61869-1:2009 | Instrument transformers General requirements |
I.S. EN 60137:2017 | INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V |
EN 60137:2017 | Insulated bushings for alternating voltages above 1 000 V |
EN 62271-205:2008/corrigendum:2008 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
EN 61952:2008 | Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
BS EN 60358-1:2012 | Coupling capacitors and capacitor dividers General rules |
CEI EN 62772 : 1ED 2017 | COMPOSITE HOLLOW CORE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGE GREATER THAN 1000 V AND D.C. VOLTAGE GREATER THAN 1500 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA |
I.S. EN 62146-1:2014 | GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL |
BS EN 62146-1 : 2014 | GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL (IEC 62146-1:2013) |
BS EN 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
BS EN 62772:2016 | Composite hollow core station post insulators for substations with a.c. voltage greater than 1 000 V and d.c. voltage greater than 1 500 V. Definitions, test methods and acceptance criteria |
UNE-EN 60137:2011 | Insulated bushings for alternating voltages above 1 000 V |
I.S. EN 61869-1:2009 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
I.S. EN 62271-205:2008 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
UNE-EN 61869-1:2010 | Instrument transformers -- Part 1: General requirements |
I.S. EN 62772:2016 | COMPOSITE HOLLOW CORE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGE GREATER THAN 1000 V AND D.C. VOLTAGE GREATER THAN 1500 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA |
BS EN 61952:2008 | Insulators for overhead lines. Composite line post insulators for A.C. systems with a nominal voltage greater than 1000 V. Definitions, test methods and acceptance criteria |
CEI EN 62271-205 : 2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
EN 60358-1:2012 | COUPLING CAPACITORS AND CAPACITOR DIVIDERS - PART 1: GENERAL RULES (IEC 60358-1:2012) |
EN IEC/IEEE 65700 : 2018 | BUSHINGS FOR DC APPLICATION (IEC/IEEE 65700-19-03:2014) |
BS EN 62271-205:2008 | High-voltage switchgear and controlgear Compact switchgear assemblies for rated voltages above 52 kV |
CEI EN 61869-1 : 2010 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
I.S. EN IEC/IEEE 65700:2018 | BUSHINGS FOR DC APPLICATION |
CEI EN 60137 : 2009 | INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V |
EN 61869-1:2009 | Instrument transformers - Part 1: General requirements |
EN 62146-1:2014/A1:2016 | GRADING CAPACITORS FOR HIGH-VOLTAGE ALTERNATING CURRENT CIRCUIT-BREAKERS - PART 1: GENERAL (IEC 62146-1:2013/A1:2016) |
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
EN ISO 1101:2017 | Geometrical product specifications (GPS) - Geometrical tolerancing - Tolerances of form, orientation, location and run-out (ISO 1101:2017) |
IEC 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V |
EN 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V |
IEC 62217:2012 | Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria |
ISO 1101:2017 | Geometrical product specifications (GPS) — Geometrical tolerancing — Tolerances of form, orientation, location and run-out |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
IEC 61166:1993 | High-voltage alternating current circuit-breakers - Guide for seismic qualification of high-voltage alternating current circuit-breakers |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
IEC TR 60865-2:2015 | Short-circuit currents - Calculation of effects - Part 2: Examples of calculation |
EN 60068-2-17:1994 | Environmental testing - Part 2: Tests - Test Q: Sealing |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
EN 60168:1994/A2:2000 | TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1KV |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
EN 62217:2013 | Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria |
IEC 60168:1994+AMD1:1997+AMD2:2000 CSV | Tests on indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V |
IEC 61006:2004 | Electrical insulating materials - Methods of test for the determination of the glass transition temperature |
IEC TR 62039:2007 | Selection guide for polymeric materials for outdoor use under HV stress |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.