• Shopping Cart
    There are no items in your cart

EN 61326-2-3:2013

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning

Published date

01-11-2013

Superseded date

06-12-2021

Superseded by

EN IEC 61326-2-3:2021

Sorry this product is not available in your region.

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 EMC test plan
6 Immunity requirements
7 Emission requirements
8 Test results and test report
9 Instructions for use
Annex A (normative) - Immunity test requirements for
        portable test and measurement equipment
        powered by battery or from the circuit
        being measured
Annex AA (normative) - Additional requirements and
         exceptions for specific types of transducers -
         Transducers for measurement of tension and
         compressive forces (force transducers)
Annex BB (normative) - Additional requirements and
         exceptions for specific types of transducers -
         Transducers for measurement of pressure
         (pressure transducers)
Annex CC (normative) - Additional requirements and
         exceptions for specific types of transducers -
         Transducers for measurement of temperature
         (temperature transducer)
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications
Annex ZZ (informative) - Coverage of Essential
         Requirements of EU Directives

IEC 61326-2-3:2012 specifies detailed test configurations, operational conditions and performance criteria for transducers with integrated or remote signal conditioning. It applies only to transducers characterized by their ability to transform, with the aid of an auxiliary energy source, a non-electric quantity to a process-relevant electrical signal, and to output the signal at one or more ports. It includes transducers for electrochemical and biological measured quantities. The transducers covered by this standard may be powered by a.c. or d.c. voltage and/or by battery or with internal power supply. This second edition cancels and replaces the first edition published in 2006. It constitutes a technical revision and includes the following significant technical change with respect to the previous edition: update of the document with respect to IEC 61326-1:2012.

Committee
CLC/TC 65X
DevelopmentNote
Supersedes EN 61326. (08/2006) To be read in conjunction with EN 61326-1. (09/2006)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

I.S. EN 61326-3-2:2008 ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - EMC REQUIREMENTS - PART 3-2: IMMUNITY REQUIREMENTS FOR SAFETY-RELATED SYSTEMS AND FOR EQUIPMENT INTENDED TO PERFORM SAFETY-RELATED FUNCTIONS (FUNCTIONAL SAFETY) - INDUSTRIAL APPLICATIONS WITH SPECIFIED ELECTROMAGNETIC ENVIRONMENT
EN 61326-3-2:2008 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment
CEI EN 61326-3-2 : 2011 ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - EMC REQUIREMENTS - PART 3-2: IMMUNITY REQUIREMENTS FOR SAFETY-RELATED SYSTEMS AND FOR EQUIPMENT INTENDED TO PERFORM SAFETY-RELATED FUNCTIONS (FUNCTIONAL SAFETY) - INDUSTRIAL APPLICATIONS WITH SPECIFIED ELECTROMAGNETIC ENVIRONMENT
BS EN 61326-3-2:2008 Electrical equipment for measurement, control and laboratory use. EMC requirements Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety). Industrial applications with specified electromagnetic environment
ETSI EN 301 489-33 V1.1.1 (2009-02) Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 33: Specific conditions for Ultra Wide Band (UWB) communications devices

2004/108/EC : 2004 DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC
EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Sorry this product is not available in your region.