EN 61267:2006
Current
The latest, up-to-date edition.
Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
01-27-2006
FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 Common aspects - Adjustment procedures
5 RQR - RADIATION QUALITIES in RADIATION BEAMS emerging
from the X-RAY SOURCE ASSEMBLY
6 RQA - RADIATION QUALITIES based on a PHANTOM made up of
an aluminium ADDED FILTER
7 RQC - RADIATION QUALITIES based on copper ADDED FILTER
8 RQT - RADIATION QUALITIES based on copper ADDED FILTER
9 Standard RADIATION CONDITIONS RQN
10 Standard RADIATION CONDITIONS RQB
11 Standard RADIATION CONDITION RQR-M
12 Standard RADIATION CONDITION RQA-M
13 Standard RADIATION CONDITIONS RQN-M
14 Standard RADIATION CONDITION RQB-M
Annex A (informative) Rationale
Annex B (informative) Determination of the amount of additional
filtration
Annex C (normative) Measurement of the PRACTICAL PEAK VOLTAGE
Annex D (informative) Overview of radiation qualities and
radiation conditions
Bibliography
Index of defined terms
This International Standard applies to test procedures which, for the determination of characteristics of systems or components of medical diagnostic X-ray equipment, require well-defined radiation conditions. Except for mammography, this standard does not apply to conditions where discontinuities in radiation absorption of elements are deliberately used to modify properties of the radiation beam (for example by rare earth filters). This standard deals with methods for generating radiation beams with radiation conditions which can be used under test conditions typically found in test laboratories or in manufacturing facilities for the determination of characteristics of medical diagnostic X-ray equipment. Examples of such radiation qualities are radiation beams emerging through the filtration from the X-ray source assembly. radiation conditions represent the more general case, where scattered radiation emerges from an exit surface of a patient or a phantom. This requires a well defined geometrical arrangement.
Committee |
CLC/TC 62
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
CEI EN 61267 : 2006 | Identical |
UNE-EN 61267:2006 | Identical |
BS EN 61267:2006 | Identical |
NBN EN 61267 : 2007 | Identical |
DIN EN 61267:2009-01 | Identical |
I.S. EN 61267:2006 | Identical |
PN EN 61267 : 2006 | Identical |
SN EN 61267 : 2006 | Identical |
NF EN 61267 : 2006 | Identical |
NEN EN IEC 61267 : 2006 | Identical |
IEC 61267:2005 | Identical |
BS EN 60738-1-4:2008 | Identical |
NEN 11267 : 1995 | Identical |
BS EN 62220-1-3:2008 | Medical electrical equipment. Characteristics of digital X-ray imaging devices Determination of the detective quantum efficiency. Detectors used in dynamic imaging |
BS EN 61674:2013 | Medical electrical equipment. Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging |
CEI EN 60406 : 1998 | CASSETTES FOR MEDICAL X-RAY DIAGNOSIS RADIOGRAPHIC CASSETTES AND MAMMOGRAPHIC CASSETTES |
BS EN 62220-1-2:2007 | Medical electrical equipment. Characteristics of digital X-ray imaging devices Determination of the detective quantum efficiency. Detectors used in mammography |
EN 60406:1997 | Cassettes for medical X-ray diagnosis - Radiographic cassettes and mammographic cassettes |
CEI EN 62220-1-2 : 2009 | MEDICAL ELECTRICAL EQUIPMENT - CHARACTERISTICS OF DIGITAL X-RAY IMAGING DEVICES - PART 1-2: DETERMINATION OF THE DETECTIVE QUANTUM EFFICIENCY - DETECTORS USED IN MAMMOGRAPHY |
BS EN 60601-2-54:2009 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-54: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR RADIOGRAPHY AND RADIOSCOPY |
I.S. EN 61674:2013 | MEDICAL ELECTRICAL EQUIPMENT - DOSIMETERS WITH IONIZATION CHAMBERS AND/OR SEMICONDUCTOR DETECTORS AS USED IN X-RAY DIAGNOSTIC IMAGING (IEC 61674:2012 (EQV)) |
EN 60627:2015 | Diagnostic X-ray imaging equipment - Characteristics of general purpose and mammographic anti-scatter grids |
CEI EN 60731 : 2012 | MEDICAL ELECTRICAL EQUIPMENT - DOSIMETERS WITH IONIZATION CHAMBERS AS USED IN RADIOTHERAPY |
BS EN 61223-3-4:2000 | Evaluation and routine testing in medical imaging departments Acceptance tests |
BS EN 60627:2015 | Diagnostic X-ray imaging equipment. Characteristics of general purpose and mammographic anti-scatter grids |
BS EN 62220-1:2004 | Medical electrical equipment. Characteristics of digital X-ray imaging devices Determination of the detective quantum efficiency |
CEI EN 62220-1-1 : 2016 | MEDICAL ELECTRICAL EQUIPMENT - CHARACTERISTICS OF DIGITAL X-RAY IMAGING DEVICES - PART 1-1: DETERMINATION OF THE DETECTIVE QUANTUM EFFICIENCY - DETECTORS USED IN RADIOGRAPHIC IMAGING |
I.S. EN 60406:1998 | CASSETTES FOR MEDICAL X-RAY DIAGNOSIS - RADIOGRAPHIC CASSETTES AND MAMMOGRAPHIC CASSETTES |
CEI EN 60627 : 2016 | DIAGNOSTIC X-RAY IMAGING EQUIPMENT - CHARACTERISTICS OF GENERAL PURPOSE AND MAMMOGRAPHIC ANTI-SCATTER GRIDS |
BS EN 60406:1997 | Specification for radiographic cassettes and mammographic cassettes used for medical X-ray diagnosis |
EN 62220-1-1:2015 | Medical electrical equipment - Characteristics of digital x-ray imaging devices - Part 1-1: Determination of the detective quantum efficiency - Detectors used in radiographic imaging |
BS EN 60731:2012 | Medical electrical equipment. Dosimeters with ionization chambers as used in radiotherapy |
I.S. EN 62220-1-3:2008 | MEDICAL ELECTRICAL EQUIPMENT - CHARACTERISTICS OF DIGITAL X-RAY IMAGING DEVICES - PART 1-3: DETERMINATION OF THE DETECTIVE QUANTUM EFFICIENCY - DETECTORS USED IN DYNAMIC IMAGING |
BS EN 62220-1-1:2015 | Medical electrical equipment. Characteristics of digital x-ray imaging devices Determination of the detective quantum efficiency. Detectors used in radiographic imaging |
CEI EN 62220-1-3 : 2010 | MEDICAL ELECTRICAL EQUIPMENT - CHARACTERISTICS OF DIGITAL X-RAY IMAGING DEVICES - PART 1: DETERMINATION OF THE DETECTIVE QUANTUM EFFICIENCY - DETECTORS USED IN DYNAMIC IMAGING |
BS EN 61223-3-1:1999 | Evaluation and routine testing in medical imaging departments Acceptance tests - Imaging performance of X-ray equipment for radiographic and radiscopic systems |
I.S. EN 62220-1-1:2015 | MEDICAL ELECTRICAL EQUIPMENT - CHARACTERISTICS OF DIGITAL X-RAY IMAGING DEVICES - PART 1-1: DETERMINATION OF THE DETECTIVE QUANTUM EFFICIENCY - DETECTORS USED IN RADIOGRAPHIC IMAGING |
CEI EN 61674 : 2014 | MEDICAL ELECTRICAL EQUIPMENT - DOSIMETERS WITH IONIZATION CHAMBERS AND/OR SEMI-CONDUCTOR DETECTORS AS USED IN X-RAY DIAGNOSTIC IMAGING |
I.S. EN 62220-1-2:2007 | MEDICAL ELECTRICAL EQUIPMENT - CHARACTERISTICS OF DIGITAL X-RAY IMAGING DEVICES - PART 1-2: DETERMINATION OF THE DETECTIVE QUANTUM EFFICIENCY - DETECTORS USED IN MAMMOGRAPHY |
I.S. EN 60731:2012 | MEDICAL ELECTRICAL EQUIPMENT - DOSIMETERS WITH IONIZATION CHAMBERS AS USED IN RADIOTHERAPY (IEC 60731:2011 (EQV)) |
EN 62220-1-2:2007 | Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-2: Determination of the detective quantum efficiency - Detectors used in mammography |
BS EN 61953:1998 | Diagnostic X-ray imaging equipment. Characteristics of mammographic anti-scatter grids |
I.S. EN 62220-1:2004 | MEDICAL ELECTRICAL EQUIPMENT - CHARACTERISTICS OF DIGITAL X-RAY IMAGING DEVICES - PART 1: DETERMINATION OF THE DETECTIVE QUANTUM EFFICIENCY |
I.S. EN 60627:2015 | DIAGNOSTIC X-RAY IMAGING EQUIPMENT - CHARACTERISTICS OF GENERAL PURPOSE AND MAMMOGRAPHIC ANTI-SCATTER GRIDS |
EN 62220-1-3:2008 | Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-3: Determination of the detective quantum efficiency - Detectors used in dynamic imaging |
EN 61674:2013 | Medical electrical equipment - Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging |
EN 62220-1:2004 | Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1: Determination of the detective quantum efficiency |
EN 60731:2012 | Medical electrical equipment - Dosimeters with ionization chambers as used in radiotherapy |
EN 60601-2-54:2009/A1:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-54: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR RADIOGRAPHY AND RADIOSCOPY |
IEC 60731:2011+AMD1:2016 CSV | Medical electrical equipment - Dosimeters with ionization chambers as used in radiotherapy |
IEC 61674:2012 | Medical electrical equipment - Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
ISO 4037-1:1996 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods |
IEC 61676:2002+AMD1:2008 CSV | Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.