Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 7: Determination of the modulation transfer function
11-24-1995
Foreword
Introduction
1 Scope
2 Normative references
3 Terminology
3.1 Definitions
3.2 Degree of requirements and reading instructions
4 Requirements
4.1 Test set-up
4.2 X-RAY IMAGE INTENSIFIER - Operating conditions
4.3 Input RADIATION
4.4 Test device
4.5 Measurement equipment
5 Determination of the MODULATION TRANSFER FUNCTION
5.1 Preparation
5.2 Measurement
5.3 Corrections
5.4 Determination of the LOW-FREQUENCY DROP
5.5 Overall accuracy of determination
6 Presentation of the MODULATION TRANSFER FUNCTION
7 Statement of compliance
Annexes
A (informative) Terminology - Index of defined terms
B (informative) Construction of the TEST DEVICE
C (informative) Determination of the MTF[A] of the MTF ANALYSER
D (informative) Bibliography
ZA (normative) Normative references to international
publications with their corresponding European
Publications
Applies to electro-optical X-ray image intensifiers for medical use, as components of diagnostic X-ray equipment. Describes a method of determining the modulation transfer function of X-ray image intensifiers.
Committee |
CLC/TC 62
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NEN 11262-7 : 1995 | Identical |
PN EN 61262-7 : 2002 | Identical |
SN EN 61262-7 : 1995 | Identical |
DIN EN 61262-7:2002-05 | Identical |
NBN EN 61262-7 : 1996 | Identical |
CEI EN 61262-7 : 1997 | Identical |
IEC 61262-7:1995 | Identical |
I.S. EN 61262-7:1997 | Identical |
NF EN 61262-7 : 1996 | Identical |
UNE-EN 61262-7:1997 | Identical |
BS EN 61262-7:1996 | Identical |
BS EN 60601-2-68:2015 | Medical electrical equipment Particular requirements for the basic safety and essential performance of X-ray-based image-guided radiotherapy equipment for use with electron accelerators, light ion beam therapy equipment and radionuclide beam therapy equipment |
EN 60601-2-68:2015 | Medical electrical equipment - Part 2-68: Particular requirements for the basic safety and essential performance of X-ray-based image-guided radiotherapy equipment for use with electron accelerators, light ion beam therapy equipment and radionuclide beam therapy equipment |
I.S. EN 60601-2-68:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-68: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY-BASED IMAGE-GUIDED RADIOTHERAPY EQUIPMENT FOR USE WITH ELECTRON ACCELERATORS, LIGHT ION BEAM THERAPY EQUIPMENT AND RADIONUCLIDE BEAM THERAPY EQUIPMENT |
EN 61262-4:1994 | Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 4: Determination of the image distortion |
IEC 60336:2005 | Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots |
IEC 61262-4:1994 | Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 4: Determination of the image distortion |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
ISO 11421:1997 | Optics and optical instruments — Accuracy of optical transfer function (OTF) measurement |
EN 60336:2005 | Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots |
HD 501 : 200S1 | MEDICAL RADIOLOGY - TERMINOLOGY |
ISO 9334:2007 | Optics and photonics Optical transfer function Definitions and mathematical relationships |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.