EN 61223-3-4 : 2000
Current
The latest, up-to-date edition.
EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-4: ACCEPTANCE TESTS - IMAGING PERFORMANCE OF DENTAL X-RAY EQUIPMENT
09-07-2000
INTRODUCTION
1 Scope and object
1.1 Scope
1.2 Object
2 Normative references
3 Terminology
3.1 Degree of requirements
3.2 Use of terms
3.3 Defined terms
4 General aspects of ACCEPTANCE TESTS
4.1 General conditions to be considered in test
procedures
4.2 Documents and data for the tests
4.3 Test conditions
4.4 Scope of tests
4.5 Test equipment including PHANTOMS and TEST
DEVICES
4.6 Evaluating the test results
5 Test methods for dental X-RAY EQUIPMENT with intra-oral
X-RAY IMAGE RECEPTOR
5.1 Visual and functional tests
5.2 *X-RAY TUBE VOLTAGE
5.3 *TOTAL FILTRATION
5.4 *FOCAL SPOT of the X-RAY TUBE
5.5 Limitation and alignment of the X-RAY BEAM
5.6 FOCAL SPOT TO SKIN DISTANCE
5.7 *Reproducibility of RADIATION OUTPUT
5.8 LINE PAIR RESOLUTION
5.9 LOW CONTRAST RESOLUTION
6 Test methods for dental panoramic X-RAY EQUIPMENT with
extra-oral X-RAY IMAGE RECEPTOR
6.1 Visual and functional tests
6.2 X-RAY TUBE VOLTAGE
6.3 TOTAL FILTRATION
6.4 FOCAL SPOT of the X-RAY TUBE
6.5 Limitation and alignment of the X-RAY BEAM
6.6 FOCAL SPOT TO SKIN DISTANCE
6.7 Reproducibility of RADIATION OUTPUT
6.8 LINE PAIR RESOLUTION
6.9 LOW CONTRAST RESOLUTION
6.10 RADIOGRAPHIC FILM cassettes with INTENSIFYING
SCREENS
6.11 Image homogeneity
6.12 Indicators for patients' positioning
6.13 Panoramic layer
7 Test methods for dental cephalometric X-RAY EQUIPMENT
with extra-oral X-RAY IMAGE RECEPTOR
7.1 Visual and functional tests
7.2 X-RAY TUBE VOLTAGE
7.3 TOTAL FILTRATION
7.4 FOCAL SPOT of the X-RAY TUBE
7.5 Limitation and alignment of the X-RAY BEAM
7.6 FOCAL SPOT TO SKIN DISTANCE
7.7 Reproducibility of RADIATION OUTPUT
7.8 LINE PAIR RESOLUTION
7.9 LOW CONTRAST RESOLUTION
7.10 RADIOGRAPHIC FILM cassettes with INTENSIFYING
SCREENS
8 Test report and statement of compliance
Annex A (normative) Terminology - Index of defined terms
Annex B (informative) Examples of requirements (accuracy,
tolerances, discrepancies) according
to actual IEC standards or state of
the art
Annex C (informative) ACCEPTANCE TEST for processing of
non-screen dental X-RAY films (non-
screen film)
Bibliography
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Figure 1 - Dental - X-RAY EQUIPMENT with intra-oral X-RAY
IMAGE RECEPTOR measuring arrangement for AIR KERMA
and resolution
Figure 2 - Dental X-RAY EQUIPMENT with intra-oral X-RAY IMAGE
RECEPTOR measuring arrangement for AIR KERMA and
resolution
Figure 3 - Dental panoramic X-RAY EQUIPMENT with extra-oral
X-RAY IMAGE RECEPTOR measuring arrangement for
AIR KERMA and resolution
Figure 4 - Example of a dental panoramic X-RAY EQUIPMENT with
extra-oral digital X-RAY IMAGE RECEPTOR measuring
arrangement for AIR KERMA, resolution, image
homogeneity and panoramic layer
Figure 5 - Example of a cephalometric X-RAY EQUIPMENT with
extra-oral X-RAY IMAGE RECEPTOR measuring
arrangement for AIR KERMA and resolution
Figure 6 - Dental PHANTOM (example)
Figure 7 - Dental PHANTOM for digital image acquisition or
processing parts (example)
Table B.1 - Typical values of FOCAL SPOT dimensions for
NORMAL FOCAL SPOT VALUES
Applies to the performance of the acceptance test on dental X-ray equipment with intra-oral X-ray image receptor and dental X-ray equipment with extra-oral X-ray image receptor (for example, dental panoramic X-ray equipment or cephalometric X-ray equipment).
Committee |
TC 62
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
BS EN 61223-3-4:2000 | Identical |
UNE-EN 61223-3-4:2002 | Identical |
PN EN 61223-3-4 : 2002 | Identical |
NF EN 61223-3-4 : 2005 | Identical |
IEC 61223-3-4:2000 | Identical |
NBN EN 61223 3-4 : 2001 | Identical |
I.S. EN 61223-3-4:2000 | Identical |
NEN EN IEC 61223-3-4 : 2000 | Identical |
DIN EN 61223-3-4:2001-10 | Identical |
SN EN 61223-3-4 : 2000 | Identical |
CEI EN 61223-3-4 : 2001 | Identical |
IEC 60336:2005 | Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots |
IEC 60417-1:2002 | Graphical symbols for use on equipment - Part 1: Overview and application |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC 60522:1999 | Determination of the permanent filtration of X-ray tube assemblies |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
ISO 2092:1981 | Light metals and their alloys Code of designation based on chemical symbols |
IEC TR 60878:2015 | Graphical symbols for electrical equipment in medical practice |
IEC 60417-2:1998 | Graphical symbols for use on equipment - Part 2: Symbol originals |
IEC 61267:2005 | Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.