EN 61124:2012
Current
The latest, up-to-date edition.

Reliability testing - Compliance tests for constant failure rate and constant failure intensity
08-10-2012
FOREWORD
1 Scope
2 Normative references
3 Terms, definitions, abbreviations and symbols
4 General requirements and area of application
5 General test procedure
6 Sequential test plans
7 Fixed time/failure terminated test plans - Fixed duration
test plans
8 Design of alternative time/failure terminated test plans
9 Calendar time/failure terminated test plans for
non-replaced items
10 Combined test plans
11 Performing the test
12 Presentation of results
Annex A (normative) - Tables and graphs for sequential test
plans
Annex B (normative) - Graphs for fixed time/failure terminated
test plans
Annex C (normative) - Graphs for alternative time/failure
terminated test plans
Annex D (normative) - Tables and graphs for combined test
plans and additional sequential test plans
Annex E (informative) - Examples and mathematical references
for sequential test plans
Annex F (informative) - Design of sequential test plans using
a common spreadsheet program
Annex G (informative) - Examples and mathematical references
for fixed time/failure terminated test plans - Fixed
duration test plans
Annex H (informative) - Design of fixed duration time/failure
terminated test plans using a spreadsheet program
Annex I (informative) - Examples and mathematical references
for the design of alternative time/failure terminated
test plans
Annex J (informative) - Examples and mathematical references
for the calendar time terminated test plans
Annex K (informative) - Derivation and mathematical reference
for the optimized test plans of GOST R 27 402
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
IEC 61124:2012 gives a number of optimized test plans, the corresponding operating characteristic curves and expected test times. In addition the algorithms for designing test plans using a spreadsheet program are also given, together with guidance on how to choose test plans. This standard specifies procedures to test whether an observed value of: failure rate, failure intensity, meantime to failure (MTTF), and mean operating time between failures (MTBF). The main changes with respect to the previous edition are as follows: - A number of new test plans have been added based on the Russian standard GOST R 27.402 [1], and it is intended to align the new edition of MIL-HDBK-781 [2] with this edition. Algorithms for optimizing test plans using a spreadsheet program are given and a number of optimized test plans are listed. Furthermore, emphasis is laid on the fact that the test should be repeated following design changes; - Discrepancies in test plans A, B as well as Annexes A and B that originated in IEC 60605-7 [3], now withdrawn, have been corrected so these test plans differ from those given in previous editions of IEC 61124. As requested by the National Committees, mathematical background material and spreadsheet program information has been moved to informative annexes. In addition, the symbol lists have been divided, so that some annexes have separate lists of symbols; - Guidance on how to choose test plans has been added as well as guidance on how to use spreadsheet programs to create them. Test plans A.1 to A.9 and B.1 to B.13 have been corrected; - Subcluses 8.1, 8.2, 8.3, Clause 9, Annex C, Clauses G.2, I.2, I.3 and Annex J are unchanged, except for updated terminology and references.
Committee |
CLC/SR 56
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NF EN 61124 : 2012 | Identical |
I.S. EN 61124:2012 | Identical |
BS EN 61124:2012 | Identical |
IEC 61124:2012 | Identical |
NBN EN 61124 : 2012 | Identical |
UNE-EN 61124:2014 | Identical |
SN EN 61124 : 2006 | Identical |
PN EN 61124 : 2012 | Identical |
CEI EN 61124 : 2013 | Identical |
NEN EN IEC 61124 : 2012 C1 2013 | Identical |
DIN EN 61124:2013-01 | Identical |
UNE-EN 61124:2012 | Identical |
I.S. EN 62506:2013 | METHODS FOR PRODUCT ACCELERATED TESTING (IEC 62506:2013 (EQV)) |
BS EN 50155:2017 | Railway applications. Rolling stock. Electronic equipment |
EN 62506:2013 | Methods for product accelerated testing |
EN 60300-3-4:2008 | Dependability management - Part 3-4: Application guide - Guide to the specification of dependability requirements |
UNE-EN 62059-31-1:2010 | Electricity metering equipment - Dependability -- Part 31-1: Accelerated reliability testing - Elevated temperature and humidity |
I.S. EN 50155:2017-11 | RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRONIC EQUIPMENT |
BS EN 62506:2013 | Methods for product accelerated testing |
BS EN 62059-31-1:2008 | Electricity metering equipment. Dependability Accelerated reliability testing. Elevated temperature and humidity |
EN 50155:2017 | Railway applications - Rolling stock - Electronic equipment |
CEI EN 62506 : 2014 | METHODS FOR PRODUCT ACCELERATED TESTING |
CEI EN 60300-3-4 : 2010 | DEPENDABILITY MANAGEMENT - PART 3-4: APPLICATION GUIDE - GUIDE TO THE SPECIFICATION OF DEPENDABILITY REQUIREMENTS |
UNE-EN 60300-3-4:2011 | Dependability management -- Part 3-4: Application guide - Guide to the specification of dependability requirements |
BS EN 60300-3-4:2008 | Dependability management Application guide. Guide to the specification of dependability requirements |
I.S. EN 60300-3-4:2008 | DEPENDABILITY MANAGEMENT - PART 3-4: APPLICATION GUIDE - GUIDE TO THE SPECIFICATION OF DEPENDABILITY REQUIREMENTS |
EN 62059-31-1:2008 | Electricity metering equipment - Dependability - Part 31-1: Accelerated reliability testing - Elevated temperature and humidity |
IEC 61123:1991 | Reliability testing - Compliance test plans for success ratio |
IEC 60605-4:2001 | Equipment reliability testing - Part 4: Statistical procedures for exponential distribution - Point estimates, confidence intervals, prediction intervals and tolerance intervals |
IEC 60605-6:2007 | Equipment reliability testing - Part 6: Tests for the validity and estimation of the constant failure rate and constant failure intensity |
MIL-HDBK-781 Revision A:1996 | RELIABILITY TEST METHODS, PLANS, AND ENVIRONMENTS FOR ENGINEERING DEVELOPMENT, QUALIFICATION AND PRODUCTION |
IEC 60605-2:1994 | Equipment reliability testing - Part 2: Design of test cycles |
GOST 27-402 : 1995 | DEPENDABILITY IN TECHNIQUES - COMPLIANCE TEST PLANS FOR MEAN TIME BETWEEN FAILURES (TO FAILURE) - PART 1 - EXPONENTIAL CASE |
IEC 60300-3-5:2001 | Dependability management - Part 3-5: Application guide - Reliability test conditions and statistical test principles |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.
Logging out.