EN 61048:2006/A1:2016
Current
The latest, up-to-date edition.
AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS (IEC 61048:2006/A1:2015)
02-19-2016
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Marking
7 Terminations
8 Creepage distances and clearances
9 Voltage rating
10 Fuses
11 Discharge resistors
12 Testing sequence
13 Sealing and heating test
14 High-voltage test
15 Resistance to adverse operating conditions
16 Resistance to heat, fire and tracking
17 Self-healing test
18 Destruction test
Annex A (normative) - Test voltage
Annex B (normative) - Temperature adjustment of test
Enclosure
Annex C (normative) - Test for conformity of manufacture
Annex D (informative) - Guide to calculating equipment
settings for tests in 15.2 and 18.1.3
Annex E (normative) - Additional requirements for built-in
capacitors having an insulation equivalent to
double or reinforced insulation
Annex F (informative) - Information for luminaire design
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Bibliography
This International Standard states the requirements for both self-healing and non-self-healing continuously rated a.c. capacitors of up to and including 2,5 kVAr, and not less than 0,1 µF, having a rated voltage not exceeding 1 000 V, which are intended for use in discharge lamp circuits operating at 50 Hz or 60 Hz and at altitudes up to 3 000 m.
| Committee |
TC 34
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Current
|
| Standards | Relationship |
| IEC 61048:2006+AMD1:2015 CSV | Identical |
| NEN 11048 : 93 AMD 1 1996 | Identical |
| VDE 0560-61 : 2016 | Identical |
| IEC 61048:2006/AMD1:2015 | Identical |
| NBN EN 61048 : 2006 AMD 1 2016 | Identical |
| I.S. EN 61048:2006 | Identical |
| DIN EN 61048 : 2016 | Identical |
| NF EN 61048 : 2006 AMD 1 2016 | Identical |
| BS EN 61048 : 2006 | Identical |
| CEI EN 61048/A1:2016 | Identical |
| NEN EN IEC 61048 : 2006 AMD 1 2016 | Identical |
| PN EN 61048 : 2009 AMD 1 2016 | Identical |
| BS EN 61048:2006+A1:2016 | Identical |
| UNE-EN 61048:2007 | Identical |
| PREN 12665 : DRAFT 2009 | LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
| BS EN 50021:1999 | Electrical apparatus for potentially explosive atmospheres. Type of prot ection \'n\' |
| I.S. EN 61642:1999 | INDUSTRIAL A.C. NETWORKS AFFECTED BY HARMONICS - APPLICATION OF FILTERS AND SHUNT CAPACITORS |
| DIN EN 12665:2016-09 (Draft) | LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
| EN 50021 : 99 COR 2000 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - TYPE OF PROTECTION "N" |
| EN 61642:1997 | Industrial a.c. networks affected by harmonics - Application of filters and shunt capacitors |
| EN 60143-1:2015/AC:2017-05 | Series capacitors for power systems - Part 1: General |
| HD 60364-5-559:2012/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-559: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - LUMINAIRES AND LIGHTING INSTALLATIONS |
| 09/30185891 DC : 0 | BS EN 12665 - LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
| I.S. HD 60364-5-559:2012 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-559: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - LUMINAIRES AND LIGHTING INSTALLATIONS (IEC 60364-5-55:2011 (MOD)) |
| CEI EN 61049 : 1998 | CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - PERFORMANCE REQUIREMENTS |
| I.S. EN 60079-15:2010 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
| I.S. EN 60931-1:1997 | SHUNT POWER CAPACITORS OF THE NON-SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AN INCLUDING 1 KV - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS GUIDE FOR INSTALLATION AND OPERATION |
| CEI EN 60079-15 : 2012 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
| EN 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
| BS EN 60079-15:2010 | Explosive atmospheres Equipment protection by type of protection \'n\' |
| DIN EN 50021 : 2000 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - TYPE OF PROTECTION "N" |
| S.R. HD 60364-5-559:2012 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-559: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - LUMINAIRES AND LIGHTING INSTALLATIONS |
| BS EN 12665:2011 | Light and lighting. Basic terms and criteria for specifying lighting requirements |
| BS EN 60143-1:2015 | Series capacitors for power systems General |
| I.S. EN 12665:2011 | LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
| EN 60931-1:1996/A1:2003 | SHUNT POWER CAPACITORS OF THE NON-SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1 KV - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION |
| UNE-EN 60079-15:2013 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
| UNE-HD 60364-5-559:2013 | Low-voltage electrical installations - Part 5-559: Selection and erection of electrical equipment - Luminaires and lighting installations |
| UNE-EN 12665:2012 | Light and lighting - Basic terms and criteria for specifying lighting requirements |
| EN 60188:2001 | High-pressure mercury vapour lamps - Performance specifications |
| EN 60192:2001 | Low pressure sodium vapour lamps - Performance specifications |
| IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
| IEC 60662:2011 | High-pressure sodium vapour lamps - Performance specifications |
| EN 61347-2-9:2013 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
| IEC 60192:2001 | Low-pressure sodium vapour lamps - Performance specifications |
| IEC 60188:2001 | High-pressure mercury vapour lamps - Performance specifications |
| IEC 61347-2-9:2012 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
| IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
| IEC 61167:2015 | Metal halide lamps - Performance specification |
| IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
| IEC 61049:1991 | Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements |
| EN 61049:1993 | Capacitors for use in tubular fluorescent and other discharge lamp circuits - Performance requirements |
| IEC 60901:1996+AMD1:1997+AMD2:2000 CSV | Single-capped fluorescent lamps - Performance specifications |
| IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
| IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
| EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
| EN 60901:1996/A6:2017 | SINGLE-CAPPED FLUORESCENT LAMPS - PERFORMANCE SPECIFICATIONS (IEC 60901:1996/A6:2014, MODIFIED) |
| EN 60662:2012 | High-pressure sodium vapour lamps - Performance specifications |
| ISO 4046-4:2002 | Paper, board, pulps and related terms — Vocabulary — Part 4: Paper and board grades and converted products |
| EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
| EN 60695-11-5:2017 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
| IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
| IEC 61347-2-8:2000+AMD1:2006 CSV | Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps |
| EN 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.