EN 61009-1:2012/A12:2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES
10-25-2021
01-12-2013
National Foreword
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Classification
5 Characteristics of RCBOs
6 Marking and other product information
7 Standard conditions for operation in
service and for installation
8 Requirements for construction and operation
9 Tests
Annex A (normative) - Test sequence and number
of samples to be submitted for certification
purposes
Annex B (normative) - Determination of clearances
and creepage distances
Annex C (normative) - Arrangement for the detection
of the emission of ionized gases during
short-circuit tests
Annex D (normative) - Routine tests
Annex E (normative) - Special requirements for auxiliary
circuits for safety extra-low voltage
Annex F (normative) - Coordination between RCBOs
and separate fuses associated in the same circuit
Annex G (normative) - Additional requirements and
tests for RCBOs consisting of a circuit-breaker
and a residual current unit designed for assembly
on site
Annex H (informative) - Void
Annex IA (informative) - Methods for determination of
short-circuit power-factor
Annex IB (informative) - Glossary of symbols
Annex IC (informative) - Examples of terminals
Annex IE (informative) - Follow-up testing programme
for RCBOs
Annex J (normative) - Particular requirements for RCBOs with
screwless type terminals for external copper conductors
Annex K (normative) - Particular requirements for RCBOs with flat
quick-connect terminations
Bibliography
Annex ZA (normative) - Normative references to
international publications with their corresponding
European publications
Annex ZB (normative) - Special national conditions
Annex ZC (informative) - A-deviations
Annex ZD (normative) - Classification of RCBOs Type B and
C up to and including 63A into energy limiting classes
Annex ZXX (Informative) - List of clauses that require retesting
Annex ZZ (informative) - Coverage of Essential
Requirements of EU Directives
Pertains to residual current operated circuit-breakers with integral overcurrent protection functionally independent of, or functionally dependent on, line voltage for household and similar uses (hereafter referred to as RCBOs), for rated voltages exceeding 440 V a.c. and rated currents not exceeding 125 A for fixed installations and rated short-circuit capacities not exceeding 25000 A.
Committee |
TC 23E
|
DevelopmentNote |
Supersedes PREN 61009-1. (12/2012)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
I.S. EN 61009-1:2012/A12:2016 | Identical |
ONORM OVE EN 61009-1 : 2016 | Identical |
VDE 0664-20 : 2016 | Identical |
NBN EN 61009-1 : 2013 AMD 3 2015 | Identical |
BS EN 61009-1 : 2012 | Identical |
CEI EN 61009-1 : 2006/A11 : 2008 | Identical |
DIN EN 61009-1 : 2016 | Identical |
CEI EN 61009-1/A11/A12:2016 | Identical |
UNE-EN 61009-1:2013 | Identical |
I.S. EN 61009-1:2012 | Identical |
PN EN 61009-1 : 2013 AMD 12 2016 | Identical |
NEN EN IEC 61009-1 : 2013 AMD 12 2016 | Identical |
SN EN 61009-1:2012+A1:2014+A2:2014+A11:2015+A12:2016 | Identical |
NF EN 61009-1 : 2013 AMD 12 2016 | Identical |
NEN EN 61009-1 : 1995 AMD 11 1995 | Identical |
BS EN 61009-1:2012+A12:2016 | Identical |
UNE-HD 50573-5-57:2014 | Co-ordination of electrical equipment for protection, isolation, switching and control |
S.R. HD 60364-5-534:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - ISOLATION, SWITCHING AND CONTROL - CLAUSE 534: DEVICES FOR PROTECTION AGAINST TRANSIENT OVERVOLTAGES |
CEI EN 50557 : 2012 | REQUIREMENTS FOR AUTOMATIC RECLOSING DEVICES (ARDS) FOR CIRCUIT BREAKERS-RCBOS-RCCBS FOR HOUSEHOLD AND SIMILAR USES |
BS EN 62040-1 : 2008 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS |
EN 50091-1-1:1996/corrigendum Aug. 2004 | |
HD 384.4.41 S2:1996/A1:2002 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 41: PROTECTION AGAINST ELECTRIC SHOCK |
HD 60364-5-534:2016 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control - Clause 534: Devices for protection against transient overvoltages |
EN 62606:2013/A1:2017 | GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES (IEC 62606:2013/A1:2017) |
HD 384.7.711 : 200S1 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-711: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - EXHIBITIONS, SHOWS AND STANDS |
BS EN 62310-1:2005 | Static transfer systems (STS) General and safety requirements |
I.S. EN 62310-1:2005 | STATIC TRANSFER SYSTEMS (STS) - PART 1: GENERAL AND SAFETY REQUIREMENTS |
I.S. EN 61543:1996 | RESIDUAL CURRENT-OPERATED PROTECTIVE DEVICES (RCDS) FOR HOUSEHOLD AND SIMILAR USE - ELECTROMAGNETIC COMPATIBILITY |
BS EN 62196-1:2014 | Plugs, socket-outlets, vehicle connectors and vehicle inlets. Conductive charging of electric vehicles General requirements |
I.S. HD 60364-7-721:2009 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-721: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - ELECTRICAL INSTALLATIONS IN CARAVANS AND MOTOR CARAVANS |
I.S. EN 62040-1:2008 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS (IEC 62040-1:2008 (EQV)) |
UNE-EN 50557:2012 | Requirements for automatic reclosing devices (ARDs) for circuit breakers-RCBOs-RCCBs for household and similar uses |
06/30146388 DC : DRAFT FEB 2006 | CENELEC TS 61643-12 - LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER SYSTEMS - SELECTION AND APPLICATION PRINCIPLES |
BS EN 61543:1996 | Residual current-operated protective devices (RCDs) for household and similar use - Electromagnetic compatibility |
UNE-HD 60364-7-722:2016 | Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles |
DIN EN 50091-1-1 : 1997 | |
CEI EN 62606 : 2014 | GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES |
HD 62640:2015/A11:2016 | RESIDUAL CURRENT DEVICES WITH OR WITHOUT OVERCURRENT PROTECTION FOR SOCKET-OUTLETS FOR HOUSEHOLD AND SIMILAR USES (IEC 62640:2011, MODIFIED) |
S.R. CLC/TS 61643-12:2009 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - SELECTION AND APPLICATION PRINCIPLES |
DD CLC/TS 61643-12:2009 | Low-voltage surge protective devices Surge protective devices connected to low-voltage power distribution systems. Selection and application principles |
UNE-HD 60364-5-53:2016 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Switchgear and controlgear |
BS EN 50557:2011 | Requirements for automatic reclosing devices (ARDs) for circuit breakers-RCBOs-RCCBs for household and similar uses |
S.R. HD 60364-5-53:2015 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
EN 63024:2018 | Requirements for automatic reclosing devices (ARDs) for circuit-breakers, RCBOs and RCCBs for household and similar uses |
HD 60364-7-722:2016 | Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles |
NF EN 50550 : 2011 AMD 1 2014 | POWER FREQUENCY OVERVOLTAGE PROTECTIVE DEVICE FOR HOUSEHOLD AND SIMILAR APPLICATIONS (POP) |
CEI 13-26 : 1999 | WATT-HOUR METERS AND POWER LIMITERS FOR LOW-VOLTAGE NETWORKS (INTEGRATED UNITS) PERMITTED OR NOT FOR PROCESSING AND REMOTE MANAGEMENT OF DATA |
EN 50550:2011/A1:2014 | POWER FREQUENCY OVERVOLTAGE PROTECTIVE DEVICE FOR HOUSEHOLD AND SIMILAR APPLICATIONS (POP) |
I.S. HD 60364-7-740:2006 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-740: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - TEMPORARY ELECTRICAL INSTALLATIONS FOR STRUCTURES, AMUSEMENT DEVICES AND BOOTHS AT FAIRGROUNDS, AMUSEMENT PARKS AND CIRCUSES |
S.R. HD 60364-7-722:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-722: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SUPPLIES FOR ELECTRIC VEHICLES |
UNE-HD 62640:2016 | Residual current devices with or without overcurrent protection for socket-outlets for household and similar uses |
UNE-HD 60364-5-534:2016 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control - Clause 534: Devices for protection against transient overvoltages |
UNE-EN 50550:2012 | Power frequency overvoltage protective device for household and similar applications (POP) |
09/30212624 DC : 0 | BS EN 50550 - POWER FREQUENCY OVERVOLTAGE PROTECTIVE DEVICE FOR HOUSEHOLD AND SIMILAR APPLICATIONS (POP) |
UNE-HD 60364-7-721:2011 | Low-voltage electrical installations - Part 7-721: Requirements for special installations or locations - Electrical installations in caravans and motor caravans |
EN 62196-1:2014 | Plugs, socket-outlets, vehicle connectors and vehicle inlets - Conductive charging of electric vehicles - Part 1: General requirements |
I.S. EN 62606:2013 | GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES |
CEI 23-105 : 2009 | RELEASE DEVICES FOR OPENING OF MCBS AND RCDS FOR HOUSEHOLD AND SIMILAR USES |
I.S. HD 50573-5-57:2014 | CO-ORDINATION OF ELECTRICAL EQUIPMENT FOR PROTECTION, ISOLATION, SWITCHING AND CONTROL |
BS EN 50091-1-1:1997 | Uninterruptible power systems (UPS) General and safety requirements for UPS used in operator access areas |
PRHD 62640 : DRAFT 2014 | RESIDUAL CURRENT DEVICES WITH OR WITHOUT OVERCURRENT PROTECTION FOR SOCKET-OUTLETS FOR HOUSEHOLD AND SIMILAR USES (IEC 62640:2011, MODIFIED) |
HD 60364-7-721:2009/corrigendum:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-721: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - ELECTRICAL INSTALLATIONS IN CARAVANS AND MOTOR CARAVANS |
I.S. HD 384.7.711:2003 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-711: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - EXHIBITIONS, SHOWS AND STANDS |
S.R. HD 60364-7-740:2006 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-740: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - TEMPORARY ELECTRICAL INSTALLATIONS FOR STRUCTURES, AMUSEMENT DEVICES AND BOOTHS AT FAIRGROUNDS, AMUSEMENT PARKS AND CIRCUSES |
BS EN 62606:2013 | General requirements for arc fault detection devices |
I.S. EN 50091-1-1:2004 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1-1: GENERAL AND SAFETY REQUIREMENTS FOR UPS USED IN OPERATOR ACCESS AREAS |
I.S. EN 63024:2018 | REQUIREMENTS FOR AUTOMATIC RECLOSING DEVICES (ARDS) FOR CIRCUIT-BREAKERS, RCBOS AND RCCBS FOR HOUSEHOLD AND SIMILAR USES |
HD 50573-5-57:2014 | Co-ordination of electrical equipment for protection, isolation, switching and control |
I.S. HD 62640:2015 | RESIDUAL CURRENT DEVICES WITH OR WITHOUT OVERCURRENT PROTECTION FOR SOCKET-OUTLETS FOR HOUSEHOLD AND SIMILAR USES |
I.S. HD 384.4.41:1998 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 41: PROTECTION AGAINST ELECTRIC SHOCK |
I.S. CLC TS 61643-12:2006 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER SYSTEMS - SELECTION AND APPLICATION PRINCIPLES |
EN 62040-1:2008/A1:2013 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS (IEC 62040-1:2008/A1:2013) |
BS EN 50550 : 2011 | POWER FREQUENCY OVERVOLTAGE PROTECTIVE DEVICE FOR HOUSEHOLD AND SIMILAR APPLICATIONS (POP) |
UNE-CLC/TS 61643-12:2012 | Low-voltage surge protective devices -- Part 12: Surge protective devices connected to low-voltage power distribution systems - Selection and application principles |
HD 60364-5-53:2015/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
HD 60364-7-740:2006/A11:2017 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-740: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - TEMPORARY ELECTRICAL INSTALLATIONS FOR STRUCTURES, AMUSEMENT DEVICES AND BOOTHS AT FAIRGROUNDS, AMUSEMENT PARKS AND CIRCUSES |
EN 61543:1995/A2:2006 | RESIDUAL CURRENT-OPERATED PROTECTIVE DEVICES (RCDS) FOR HOUSEHOLD AND SIMILAR USE - ELECTROMAGNETIC COMPATIBILITY |
EN 62310-1:2005 | Static transfer systems (STS) - Part 1: General and safety requirements |
EN 50557:2011 | Requirements for automatic reclosing devices (ARDs) for circuit breakers-RCBOs-RCCBs for household and similar uses |
CLC/TS 61643-12:2009 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - SELECTION AND APPLICATION PRINCIPLES |
CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
IEC 60038:2009 | IEC standard voltages |
EN 60998-1:2004 | Connecting devices for low-voltage circuits for household and similar purposes - Part 1: General requirements |
IEC 60998-1:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 1: General requirements |
IEC 60364-4-43:2008 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
EN 61543:1995/A2:2006 | RESIDUAL CURRENT-OPERATED PROTECTIVE DEVICES (RCDS) FOR HOUSEHOLD AND SIMILAR USE - ELECTROMAGNETIC COMPATIBILITY |
IEC 60228:2004 | Conductors of insulated cables |
EN 60998-2-2:2004 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units |
HD 60364-4-43:2010 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 60884-1:2002+AMD1:2006+AMD2:2013 CSV | Plugs and socket-outlets for household and similar purposes - Part1: General requirements |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
IEC 61543:1995 | Residual current-operated protective devices (RCDs) for household and similar use - Electromagnetic compatibility |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
WC 8:1988 | ETHYLENE-PROPYLENE-RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
EN 60112 : 2003 AMD 1 2009 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
ASTM B 172 : 2017 : REDLINE | Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors |
HD 60364-4-444:2010/AC:2012 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-444: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES |
EN 60060-2:2011 | High-voltage test techniques - Part 2: Measuring systems |
IEC 60050-101:1998 | International Electrotechnical Vocabulary (IEV) - Part 101: Mathematics |
IEC 60998-2-2:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units |
IEC TR 60755:2008 | General requirements for residual current operated protective devices |
IEC 62640:2011+AMD1:2015 CSV | Residual current devices with or without overcurrent protection forsocket-outlets for household and similar uses |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
WC 3-1992 | RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
IEC 60664-5:2007 | Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm |
EN 60898-1:2003/A13:2012 | ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED) |
IEC 60898-1:2015 | Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation |
EN 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
EN 60068-3-4:2002 | Environmental testing - Part 3-4: Supporting documentation and guidance - Damp heat tests |
EN 61008-1:2012/A12:2017 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBS) - PART 1: GENERAL RULES (IEC 61008-1:2010, MODIFIED) |
IEC 60068-3-4:2001 | Environmental testing - Part 3-4: Supporting documentation and guidance - Damp heat tests |
IEC 60947-2:2016 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 60947-2:2017 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
IEC 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60664-3:2017 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
EN 60898-1:2003/A13:2012 | ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED) |
EN 55014-1:2017 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
EN 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
WC 7-1988 | CROSS-LINKED-THERMOSETTING-POLYETHYLENE-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.