EN 61000-5-7:2001
Current
The latest, up-to-date edition.
Electromagnetic compatibility (EMC) - Part 5-7: Installation and mitigation guidelines - Degrees of protection by enclosures against electromagnetic disturbances (EM code)
04-02-2001
Introduction
1 Scope
2 Normative references
3 General
4 Definitions
5 Shielding performance designations
6 General test approach
7 Testing requirements
7.1 Climatic conditions
7.2 Test samples
7.3 Analysis requirements
7.4 Test frequency selection
7.5 Test matrix definition
7.6 Test equipment requirements
7.7 Safety requirements
7.8 Test plan requirements
7.9 Test performance
7.10 Test conclusions
7.11 Test documentation
8 Classification
Annex A (informative) Some issues for selection of
enclosure electromagnetic protection
requirements
Annex B (informative) Summary of responsibilities of
relevant end-product technical committees
Annex C (informative) Other test methods - TEM cells
and strip lines
Annex D (informative) Antennas
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Bibliography
Describes performance requirements, test methods and classification procedures for degrees of protection provided by empty enclosures against electromagnetic disturbances for frequencies between 10 kHz and 40 GHz. The shielding protection is measured for the purpose of demonstrating that the enclosure provides adequate shielding of electromagnetic energy to support acceptable performance of the complete assembled units when tested to applicable IEC standards. The purpose of this standard is to provide a repeatable means for evaluating the electromagnetic shielding performance of empty mechanical enclosures, including cabinets and subracks, and to specify a marking code to allow a manufacturer to select an enclosure with a known capability for attenuating electromagnetic fields. The requirements for immunity to various types of electromagnetic disturbances, including lightning and high-altitude electro-magnetic pulse (HEMP) will need to be considered by manufacturers when determining the need for application of this standard for specific equipment and applications, and for the specific enclosure shielding requirements which are necessary as a function of frequency.
Committee |
CLC/TC 210
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
IEC 61000-5-7:2001 | Identical |
NBN EN 61000 5-7 : 2001 | Identical |
NEN EN IEC 61000-5-7 : 2001 | Identical |
I.S. EN 61000-5-7:2001 | Identical |
PN EN 61000-5-7 : 2005 | Identical |
SN EN 61000-5-7 : 2001 | Identical |
DIN EN 61000-5-7 : 2001 | Identical |
VDE 0847-5-7 : 2001 | Identical |
UNE-EN 61000-5-7:2002 | Identical |
BS EN 61000-5-7:2001 | Identical |
CEI EN 61000-5-7 : 2003 | Identical |
NF EN 61000-5-7 : 2001 | Identical |
BS EN 61587-3:2013 | Mechanical structures for electronic equipment. Tests for IEC 60917 and IEC 60297 Electromagnetic shielding performance tests for cabinets and subracks |
CEI EN 61587-3 : 2014 | MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 3: ELECTROMAGNETIC SHIELDING PERFORMANCE TESTS FOR CABINETS AND SUBRACKS |
PD CLC/TR 50659:2017 | Electromagnetic characteristics of linear cable management systems (CMS) |
EN 62208:2011 | Empty enclosures for low-voltage switchgear and controlgear assemblies - General requirements |
BS EN 62208:2011 | Empty enclosures for low-voltage switchgear and controlgear assemblies. General requirements |
CLC/TR 50659:2017 | Electromagnetic characteristics of linear cable management systems (CMS) |
S.R. CLC/TR 50659:2017 | ELECTROMAGNETIC CHARACTERISTICS OF LINEAR CABLE MANAGEMENT SYSTEMS (CMS) |
PD CLC/TR 50373:2004 | Wind turbines. Electromagnetic compatibility |
CLC/TR 50373:2004 | Wind turbines - Electromagnetic compatibility |
I.S. EN 61587-3:2013 | MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 3: ELECTROMAGNETIC SHIELDING PERFORMANCE TESTS FOR CABINETS AND SUBRACKS (IEC 61587-3:2013 (EQV)) |
EN 61587-3:2013 | Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets and subracks |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
IEC 61000-4-23:2016 | Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.