EN 60966-1:1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Radio frequency and coaxial cable assemblies - Part 1: Generic specification - General requirements and test methods
02-11-2022
06-02-1999
1 Scope
2 Normative References
3 Definitions
4 Design and Manufacturing Requirements
4.1 Cable design and construction
4.2 Connector design and construction
4.3 Outline and interface dimensions
5 Workmanship, marking and packaging
5.1 Workmanship
5.2 Marking
5.3 End caps
5.4 Packaging and labelling
6 Quality Assessment
7 Test Methods - General
7.1 Standard atmospheric conditions for testing
7.2 Visual inspection
7.3 Dimensions inspection
8 Electrical Tests
8.1 Reflection properties
8.2 Uniformity of impedance
8.3 Insertion loss
8.4 Insertion loss stability
8.5 Propagation time
8.6 Stability of electrical length
8.7 Phase difference
8.8 Phase variation with temperature
8.9 Screening effectiveness
8.10 Voltage proof
8.11 Insulation resistance
8.12 Inner and outer Conductor continuity
8.13 Void
8.14 Power rating
8.15 Intermodulation level measurement
9 Mechanical Robustness Tests
9.1 Tensile
9.2 Flexure
9.3 Flexing endurance
9.4 Cable assembly crushing
9.5 Torque
9.6 Multiple bending
9.7 Abrasion test of cable assembly
9.8 Vibrations, shocks and impact
9.9 Mechanical endurance
10 Environmental Tests
10.1 Recommended severities
10.2 Vibration, bumps and shock
10.3 Climatic sequence
10.4 Damp heat, steady state
10.5 Rapid change of temperature
10.6 Solvents and contaminating fluids
10.7 Water immersion
10.8 Salt mist and sulphur dioxide tests
10.9 Dust tests
10.10 Flammability
11 Specialized Test Methods
12 Test Schedules
Annex A (normative) Test Methods for Insertion Loss
Determination
A.1 - Purpose
A.2 - Test Methods
A.2.1 - Test Method 1
A.2.2 - Test Method 2
A.2.3 - Test Method 3
A.3 - Correction for Characteristic Impedance
Differences
Annex B (informative) Measuring Methods for Propagation Time
B.1 - Resonance Method for Propagation Time Measurement
B.2 - Time Domain Method for Propagation Time Measurement
Annex C (informative) Measurement Method for Screening
Effectiveness
C.1 - Introduction
C.2 - Test Method
Annex D (informative) Recommended Severities for Environmental
Tests
D.1 - Introduction to the Relationship between
Environmental Conditions and Test Severities
D.1.1 - General
D.1.2 - Environmental Conditions
D.1.3 - Environmental Testing
D.2 - Severities for Environmental Testing
D.2.1 - Vibration
D.2.2 - Bump
D.2.3 - Shock
D.2.4 - Climatic Sequence
D.2.5 - Damp Heat, Steady State
D.2.6 - Rapid Change of Temperature
D.2.7 - Salt Mist
D.2.8 - Sulphur Dioxide Test
D.2.9 - Dust Test
Annex E (normative) Quality Assessment
E.1 - Object
E.2 - General
E.2.1 - Related Documents
E.2.2 - Standards and Preferred Values
E.2.3 - Marking of the Cable Assembly and
Packaging
E.2.4 - Terminology
E.3 - Quality Assessment Procedures
E.3.1 - Procedures for Qualification Approval
E.3.2 - Procedures for Capability Approval
E.3.3 - Quality Conformance Inspection
E.4 - Capability Manual and Approval
E.4.1 - Responsibilities
E.4.2 - Contents of the Capability Manual
E.4.3 - Criteria for Capability Limits
Annex ZA (normative) Normative References to International
Publications with their corresponding
European Publications
Table D.1 - Relationship between Displacement and Acceleration
Table D.2 - Relationship between Peak Acceleration and Velocity
Change
Table E.1 - Example of Capability Limits for Cable Assemblies
Table E.2 - Example of Capability Limits for Flexible Cables
Table E.3 - Example of Capability Limits for Connectors
Table E.4 - Example of Flow Chart
Figure 1 - Bending Test: U Shape Assembly
Figure 2 - Bending Test: Straight Assembly
Figure 3 - Twisting Test: U Shape Assembly
Figure 4 - Fixture for Cable Assembly Flexure Test
Figure 5 - Apparatus for Cable Assembly Flexing Endurance Test
Figure 6 - Fixture for Cable Crushing Test
Figure 7 - Multiple Bending Test
Figure 8 - Dust Measuring Device
Figure A.1 - Circuit for the Determination of Insertion Loss
Figure A.2 - Circuit for the Determination of Insertion Loss
Figure A.3 - Alternative Circuit for the Determination of
Insertion Loss
Figure A.4 - Double-Pass Circuit for the Determination of
Insertion Loss
Figure B.1 - Arrangement of Test Equipment
Figure C.1 - Line Injection Test Circuit for Coaxial Cable
Assemblies
Figure C.2 - Schematic Transfer Functions of a Coaxial Cable
Assembly
Figure C.3 - Complete Installation for Practical Screening
Effectiveness Measurements
Figure D.1 - Description of Action Needed for the Preparation
of the Environmental Test Specification
Establishes uniform requirements for testing the electrical, mechanical and climatic properties of r.f. and coaxial cable assemblies composed of cables and connectors operating in the transverse electromagnetic mode (TEM). Tests are described in IEC 61196-1 and IEC 61169-1 respectively.
Committee |
CLC/TC 46X
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
I.S. EN 60966-1:1993 | Identical |
NBN EN 60966-1 : 2000 | Identical |
NF EN 60966-1 : 1999 | Identical |
IEC 60966-1:1999 | Identical |
NEN EN IEC 60966-1 : 1999 | Identical |
SN EN 60966-1 : 1999 | Identical |
DIN EN 60966-1 : 1999 | Identical |
PN-EN 60966-1:2002 | Identical |
UNE-EN 60966-1:1999 | Identical |
CEI EN 60966-1 : 2001 | Identical |
BS EN 60966-1:1999 | Identical |
OVE/ONORM EN 60966-1 : 2000 | Identical |
NEN 10966-1 : 1993 | Identical |
BS EN 60966-2-5:2017 | Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 1 000 MHz, IEC 61169-2 connectors |
CEI EN 60966-2-6 : 2010 | RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-6: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-24 CONNECTORS |
CEI EN 60966-2-3 : 2010 | RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-3: DETAIL SPECIFICATION FOR FLEXIBLE COAXIAL CABLE ASSEMBLIES - FREQUENCY RANGE 0 MHZ TO 1000 MHZ, IEC 61169-8 CONNECTORS |
UNE-EN 50083-2:2013 | Cable networks for television signals, sound signals and interactive services - Part 2: Electromagnetic compatibility for equipment |
EN 60728-4:2008 | Cable networks for television signals, sound signals and interactive services - Part 4: Passive wideband equipment for coaxial cable networks |
EN 60966-3:2009 | Radio frequency and coaxial cable assemblies - Part 3: Sectional specification for semi-flexible coaxial cable assemblies |
EN 60966-2-5:2017 | Radio frequency and coaxial cable assemblies - Part 2-5: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 1 000 MHz, IEC 61169-2 connectors |
EN 60966-2-4:2016 | Radio Frequency and coaxial cable assemblies - Part 2-4: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-2 connectors |
EN 60966-4:2003 | Radio frequency and coaxial cable assemblies - Part 4: Sectional specification for semi-rigid coaxial cable assemblies |
EN 50083-2:2012/A1:2015 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 2: ELECTROMAGNETIC COMPATIBILITY FOR EQUIPMENT |
BS EN 50529-2:2010 | EMC network standard Wire-line telecommunications networks using coaxial cables |
I.S. EN 60966-2-6:2017 | RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-6: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-24 CONNECTORS |
BS EN 60966-2-6:2017 | Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 3 000 MHz, IEC 61169-24 connectors |
I.S. EN 60966-2-1:2009 | RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-1: SECTIONAL SPECIFICATION FOR FLEXIBLE COAXIAL CABLE ASSEMBLIES |
BS EN 60966-2-3:2009 | Radio frequency and coaxial cable assemblies Detail specification for flexible coaxial cable assemblies. Frequency range 0 MHz to 1000 MHz, IEC 61169-8 connectors |
I.S. EN 60966-2-3:2009 | RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-3: DETAIL SPECIFICATION FOR FLEXIBLE COAXIAL CABLE ASSEMBLIES - FREQUENCY RANGE 0 MHZ TO 1000 MHZ, IEC 61169-8 CONNECTORS |
CEI EN 50083-2 : 2012 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 2: ELECTROMAGNETIC COMPATIBILITY FOR EQUIPMENT |
BS EN 60966-2-7:2016 | Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 3 000 MHz, IEC 61169-47 connectors |
BS EN 60728-4:2008 | Cable networks for television signals, sound signals and interactive services Passive wideband equipment for coaxial cable networks |
BS EN 60966-3:2009 | Radio frequency and coaxial cable assemblies Sectional specification for semi-flexible coaxial cable assemblies |
BS EN 60966-4:2003 | Radio frequency and coaxial cable assemblies Sectional specification for semi-rigid coaxial cable assemblies |
CEI EN 60966-3 : 2010 | RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 3: SECTIONAL SPECIFICATION FOR SEMI-FLEXIBLE COAXIAL CABLE ASSEMBLIES |
I.S. EN 50529-2:2010 | EMC NETWORK STANDARD - PART 2: WIRE-LINE TELECOMMUNICATIONS NETWORKS USING COAXIAL CABLES |
BS EN 60966-2-1:2009 | Radio frequency and coaxial cable assemblies Sectional specification for flexible coaxial cable assemblies |
CEI EN 60966-2-1 : 2010 | RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-1: SECTIONAL SPECIFICATION FOR FLEXIBLE COAXIAL CABLE ASSEMBLIES |
BS EN 60966-2-4:2009 | Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 3 000 MHz, IEC 61169-2 connectors |
CEI EN 60966-2-4 : 2010 | RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-4: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-2 CONNECTORS |
I.S. EN 50083-2:2012 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 2: ELECTROMAGNETIC COMPATIBILITY FOR EQUIPMENT |
I.S. EN 60966-2-5:2017 | RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-5: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 1000 MHZ, IEC 61169-2 CONNECTORS |
CEI EN 50529-2 : 2013 | EMC NETWORK STANDARD - PART 2: WIRE-LINE TELECOMMUNICATIONS NETWORKS USING COAXIAL CABLES |
BS EN 50083-2 : 2012 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 2: ELECTROMAGNETIC COMPATIBILITY FOR EQUIPMENT |
I.S. EN 60966-2-4:2016 | RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-4: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-2 CONNECTORS |
CEI EN 60728-4 : 2008 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 4: PASSIVE WIDEBAND EQUIPMENT FOR COAXIAL CABLE NETWORKS |
I.S. EN 60966-2-7:2016 | RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-7: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-47 CONNECTORS |
CEI EN 60966-2-5 : 2010 | RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-5: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 1000 MHZ, IEC 61169-2 CONNECTORS |
I.S. EN 60966-3:2003 | RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 3: SECTIONAL SPECIFICATION FOR SEMI-FLEXIBLE COAXIAL CABLE ASSEMBLIES |
TR 102 864 : 1.1.1 | ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); ASSESSMENT OF CABLE EQUIPMENT WITH DIGITAL DIVIDEND; NEW ELECTRONIC COMMUNICATION NETWORKS (ECN) OPERATING IN THE UHF BAND 790 MHZ TO 862 MHZ |
TR 102 994 : 1.1.1 | ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); IN HOME CABLING FOR INTEGRATED BROADBAND CABLE AND TELEVISION SERVICES |
I.S. EN 60728-4:2008 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 4: PASSIVE WIDEBAND EQUIPMENT FOR COAXIAL CABLE NETWORKS |
EN 60966-2-1:2009 | Radio frequency and coaxial cable assemblies - Part 2-1: Sectional specification for flexible coaxial cable assemblies |
EN 60966-2-6:2017 | Radio frequency and coaxial cable assemblies - Part 2-6: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-24 connectors |
EN 60966-2-3:2009 | Radio frequency and coaxial cable assemblies - Part 2-3: Detail specification for flexible coaxial cable assemblies - Frequency range 0 MHz to 1 000 MHz, IEC 61169-8 connectors |
EN 50529-2:2010 | EMC Network Standard - Part 2: Wire-line telecommunications networks using coaxial cables |
EN 60966-2-7:2016 | Radio frequency and coaxial cable assemblies - Part 2-7: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-47 connectors |
IEC 60068-2-68:1994 | Environmental testing - Part 2-68: Tests - Test L: Dust and sand |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60332-1:1993 | Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable |
ISO 9002:1994 | Quality systems — Model for quality assurance in production, installation and servicing |
IEC 61169-1:2013 | Radio frequency connectors - Part 1: Generic specification - General requirements and measuring methods |
IEC 60068-2-3:1969 | Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state |
ISO 9001:2015 | Quality management systems — Requirements |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
IEC 60068-2-29:1987 | Environmental testing. Part 2: Tests. Test Eb and guidance: Bump |
IEC 61196-1:2005 | Coaxial communication cables - Part 1: Generic specification - General, definitions and requirements |
IEC 60512-5:1992 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 5: Impact tests (free components), static load tests (fixed components), endurance tests and overload tests |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 61726:2015 | Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.