EN 60947-6-2:2003/A1:2007
Current
The latest, up-to-date edition.
LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 6-2: MULTIPLE FUNCTION EQUIPMENT - CONTROL AND PROTECTIVE SWITCHING DEVICES (OR EQUIPMENT) (CPS)
03-30-2007
INTRODUCTION
1 Scope and object
2 Normative references
3 Definitions
3.1 Control and protective switching device
(or equipment) (CPS)
3.2 CPS suitable for isolation
3.3 CPS for motor control and protection
3.4 Opening time
3.5 Phase loss sensitive relay or release (for
motor protection)
4 Classification
5 Characteristics
5.1 Summary of characteristics
5.2 Type of CPS
5.3 Rated and limiting values of the main circuit
5.4 Utilization categories
5.5 Control circuits
5.6 Auxiliary circuits
5.7 Relays or releases
6 Product information
6.1 Nature of information
6.2 Marking
6.3 Instructions for installation, operation and
maintenance
7 Normal service, mounting and transport conditions
8 Constructional and performance requirements
8.1 Constructional requirements
8.2 Performance requirements
8.3 Electromagnetic compatibility (EMC)
9 Tests
9.1 Kind of tests
9.2 Compliance with constructional requirements
9.3 Compliance with performance requirements
9.4 Tests sequences
9.5 Routine tests
Annex A (normative) - Special tests
Annex C (normative) - Marking and identification of CPS
terminals
Annex D (informative) - Items subject to agreement between
manufacturer and user
Annex E (informative) - Examples of control circuit configurations
Annex F (normative) - Coordination under short-circuit conditions
between a CPS and another short-circuit protective
device associated in the same circuit
Annex G (normative) - Test sequence for CPSs for IT systems
Annex H (normative) - Extended functions within electronic
overload relays or releases
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Applies to control and protective switching devices (or equipment) (CPS), the main contacts of which are intended to be connected to circuits with rated voltage exceeding 1000 V a.c. or 1500 V d.c.
Committee |
TC 121A
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NF EN 60947 6-2 : 2003 AMD 1 2007 | Identical |
IEC 60947-6-2:2002+AMD1:2007 CSV | Identical |
NBN EN 60947 6-2 : 2003 AMD 1 2007 | Identical |
NEN EN IEC 60947-6-2 : 2003 AMD 1 2007 | Identical |
I.S. EN 60947-6-2:2003 | Identical |
PN EN 60947-6-2 : 2005 AMD 1 2010 | Identical |
SN EN 60947-6-2 : 2003 | Identical |
DIN EN 60947-6-2 : 2007 | Identical |
VDE 0660-115 : 2007 | Identical |
CEI EN 60947-6-2/A1 ; 2008 | Identical |
UNE-EN 60947-6-2:2005 | Identical |
BS EN 60947-6-2:2003 | Identical |
OVE/ONORM EN 60947-6-2 : 2008 | Identical |
DS EN 60947-6-2 : 2003 AMD 1 2007 | Identical |
NEN 10947-6-2 : 1993 C1 1997 | Similar to |
UNE-HD 50573-5-57:2014 | Co-ordination of electrical equipment for protection, isolation, switching and control |
S.R. HD 60364-5-537:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING |
EN 60947-6-1:2005/A1:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 6-1: MULTIPLE FUNCTION EQUIPMENT - TRANSFER SWITCHING EQUIPMENT (IEC 60947-6-1:2005/A1:2013) |
EN 62683:2015 | Low-voltage switchgear and controlgear - Product data and properties for information exchange |
HD 60364-4-43:2010 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
EN 303 446-2 : 1.1.0 DRAFT | ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR COMBINED AND/OR INTEGRATED RADIO AND NON-RADIO EQUIPMENT; PART 2: SPECIFIC CONDITIONS FOR EQUIPMENT INTENDED TO BE USED IN INDUSTRIAL LOCATIONS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.1(B) OF DIRECTIVE 2014/53/EU |
S.R. HD 60364-5-53:2015 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
BS EN 62683:2015 | Low-voltage switchgear and controlgear. Product data and properties for information exchange |
UNE-HD 60364-5-53:2016 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Switchgear and controlgear |
01/712575 DC : DRAFT SEP 2001 | ISO 13849-2 - SAFETY OF MACHINERY - SAFETY-RELATED PARTS OF CONTROL SYSTEM - PART 2: VALIDATION |
I.S. EN 60947-6-1:2005 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 6-1: MULTIPLE FUNCTION EQUIPMENT - TRANSFER SWITCHING EQUIPMENT |
HD 60364-7-722:2016 | Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles |
I.S. HD 60364-4-43:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-43: PROTECTION FOR SAFETY - PROTECTION AGAINST OVERCURRENT |
S.R. HD 60364-7-722:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-722: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SUPPLIES FOR ELECTRIC VEHICLES |
UNE-HD 60364-4-43:2013 | Low-voltage electrical installations -- Part 4-43: Protection for safety - Protection against overcurrent |
HD 60364-5-537:2016/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING |
I.S. HD 50573-5-57:2014 | CO-ORDINATION OF ELECTRICAL EQUIPMENT FOR PROTECTION, ISOLATION, SWITCHING AND CONTROL |
UNE-EN 60947-6-1:2006 | Low-voltage switchgear and controlgear -- Part 6-1: Multiple function equipment - Transfer switching equipment (IEC 60947-6-1:2005) |
UNE-HD 60364-7-722:2016 | Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles |
BS EN 60947-6-1:2005 | Low-voltage switchgear and controlgear Multiple function equipment. Transfer switching equipment |
HD 50573-5-57:2014 | Co-ordination of electrical equipment for protection, isolation, switching and control |
HD 60364-5-53:2015/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
UNE-HD 60364-5-537:2017 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Devices for protection, isolation, switching, control and monitoring - Clause 537: Isolation and switching |
EN 60085:2008 | Electrical insulation - Thermal evaluation and designation |
EN 60034-1:2010/corrigendum Oct. 2010 | ROTATING ELECTRICAL MACHINES - PART 1: RATING AND PERFORMANCE |
EN 61131-2:2007 | Programmable controllers - Part 2: Equipment requirements and tests |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
IEC 60695-2-13:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 60695-2-13:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-13: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE IGNITION TEMPERATURE (GWIT) TEST METHOD FOR MATERIALS (IEC 60695-2-13:2010/A1:2014) |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
EN 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
IEC 61131-2:2017 | Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
EN 60947-6-1:2005/A1:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 6-1: MULTIPLE FUNCTION EQUIPMENT - TRANSFER SWITCHING EQUIPMENT (IEC 60947-6-1:2005/A1:2013) |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
IEC 60947-2:2016 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
EN 60947-2:2017 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
IEC 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC 60947-6-1:2005+AMD1:2013 CSV | Low-voltage switchgear and controlgear - Part 6-1: Multiple functionequipment - Transfer switching equipment |
EN 60695-2-12:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS (IEC 60695-2-12:2010/A1:2014) |
EN 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.