EN 60601-2-32:1994
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Medical electrical equipment - Part 2: Particular requirements for the safety of associated equipment of X-ray equipment
01-01-2013
07-14-1994
Committees responsible
National foreword
Foreword
Section one - General
1. Scope and object
2. Terminology and definitions
3. General requirements for tests
4. Identification, marking and documents
Section two - Environmental conditions
Section three - Protection against electric shock
hazards
Section four - Protection against mechanical hazards
21. Mechanical strength
22. Moving parts
24. Stability in NORMAL USE
28. Suspended masses
Section five - Protection against hazards from unwanted
or excessive radiation
Section six - Protection against hazards of ignition of
flammable anaesthetic mixtures
Section seven - Protection against excessive
temperatures and other safety hazards
Section eight - Accuracy of operating data and
protection against hazardous output
Section nine - Abnormal operation and fault conditions;
environmental tests
Section ten - Constructional requirements
Tables
101. Drop height
102. Static load
Appendix L - References - Publications mentioned in
this Standard
Annex AA - Index of defined terms
Annex ZA - (normative) Other international publications
quoted in this standard with the references of the
relevant European publications
Annex ZB - (informative) Other international
publications quoted in this standard with the
references of the relevant European publications
Applies to equipment and devices associated to X-ray equipment as used for supporting and relatively positioning the functional components including the patient support used for the application of the X-radiation. This standard applies to all associated equipment not covered by other Particular Standards.
Committee |
CLC/TC 62
|
DevelopmentNote |
To be read in conjunction with EN 60601-1:1990 and EN 60601-1-3:1994 (05/2001)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
BS EN 60601-2-32:1995 | Identical |
IEC 60601-2-32:1994 | Identical |
NBN EN 60601 2-32 : 1995 | Identical |
NEN 10601-2-32 : 1994 | Identical |
I.S. EN 60601-2-32:1994 | Identical |
PN EN 60601-2-32 : 2006 | Identical |
SN EN 60601-2-32 : 1994 | Identical |
VDE 0750-2-32 : 1995 | Identical |
BS 5724-2.32(1995) : 1995 | Identical |
UNE-EN 60601-2-32:1996 | Identical |
CEI EN 60601-2-32 : 1998 | Identical |
DIN EN 60601-2-32 : 1995 | Identical |
NF EN 60601 2-32 : 1994 | Identical |
EN 60601-2-63:2015 | Medical electrical equipment - Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment |
BS EN 60601-2-45 : 2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-45: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT AND MAMMOGRAPHIC STEREOTACTIC DEVICES |
BS EN 60601-2-63:2015 | Medical electrical equipment Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment |
UNE-EN 60601-2-44:2010 | Medical electrical equipment -- Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography |
BS EN 60601-2-54:2009 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-54: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR RADIOGRAPHY AND RADIOSCOPY |
EN 60601-2-45:2011/A1:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-45: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT AND MAMMOGRAPHIC STEREOTACTIC DEVICES (IEC 60601-2-45:2011/A1:2015) |
EN 60601-2-54:2009/A1:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-54: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR RADIOGRAPHY AND RADIOSCOPY |
IEC 60601-2-7:1998 | Medical electrical equipment - Part 2-7: Particular requirements for the safety of high-voltage generators of diagnostic X-ray generators |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
ISO 6892:1998 | Metallic materials Tensile testing at ambient temperature |
IEC 60601-2-8:2010+AMD1:2015 CSV | Medical electrical equipment - Part 2-8: Particular requirements forthe basic safety and essential performance of therapeutic X-ray equipment operating in the range 10 kV to 1 MV |
IEC 60601-2-15:1988 | Medical electrical equipment. Part 2: Particular requirements for the safety of capacitor discharge X-ray generators |
IEC 60601-1-3:2008+AMD1:2013 CSV | Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.