EN 60229:2008
Current
The latest, up-to-date edition.
Electric cables - Tests on extruded oversheaths with a special protective function
06-04-2008
FOREWORD
1 Scope
2 Normative references
3 Routine tests
3.1 D.C. voltage test
3.2 Spark test
4 Type tests
4.1 Abrasion test
4.1.1 Purpose
4.1.2 Test procedure
4.1.3 Inspection
4.1.4 Performance requirement
4.2 Corrosion spread (aluminium metallic screen only)
4.2.1 General
4.2.2 Test procedure
4.2.3 Inspection
4.2.4 Performance requirement
5 Electrical test after installation
Annex A (normative) Application of the abrasion test
Annex B (informative) Guidance on tests after installation
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Provides a range of tests which may be required for electric cables which have an extruded oversheath and where that oversheath performs a special protective function. The standard covers cables for use in insulated systems and in uninsulated systems. The tests are categorized for use as routine tests, type tests and tests after installation. These tests comprise of electrical routine tests on cable oversheath used in insulated or uninsulated systems, abrasion and corrosion spread type tests, electrical test on cable oversheath after installation. Routine tests and tests after installation, as specified in the relevant cable standards, are applicable for all situations. Type tests depend upon the nature of the system and the construction of the cable and do not have to be carried out for normal conditions of use. The significant technical changes with respect to the previous edition are as follows: - The text has been modified in order to consider the function of the oversheath, irrespective of the way the metallic sheath or screen of the cable is earthed because, in some cases, the oversheath is designed to act not only as a protection against corrosion, but also to reduce the risk of degradation of the cable insulation system. This requirement may be independent of the nature of the insulation and independent of the rated voltage of the cable. - More precise wording has been introduced regarding the application of some tests (if the sheaths or foils are bonded to the oversheath or not). - The test requirements have been revised in order to be in line with the standards published after the second edition. - The pressure test at high temperature has been deleted as the requirement is specified in the relevant cable standards. - A 'Guidance on tests after installation' (Annex B) has been included.
Committee |
CLC/TC 20
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NF EN 60229 : 2008 | Identical |
IEC 60229:2007 | Identical |
NBN EN 60229 : 2008 | Identical |
NEN EN IEC 60229 : 2008 | Identical |
I.S. EN 60229:2008 | Identical |
PN EN 60229 : 2008 | Identical |
DIN EN 60229 : 2009 | Identical |
VDE 0473-229 : 2009 | Identical |
BS EN 60229:2008 | Identical |
CEI EN 60229 : 2010 | Identical |
UNE-EN 60229:2009 | Identical |
BS EN IEC 60191-1:2018 | Identical |
CEI EN 62271-204 : 2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGES ABOVE 52 KV |
HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
UNE-EN 62271-204:2012 | High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV |
I.S. HD 632:2016 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
ESPECIFICACION UNE 0051:2017 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTE insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1 and type 3). |
ESPECIFICACION UNE 0052:2017 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
UNE-HD 620-10E:2012 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 10: XLPE insulated single core and 3 core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 10E-1, 10E-3, 10E-4 and 10E-5). |
UNE-HD 620-9E:2012 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 9: HEPR insulated single core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 9E-1, 9E-3, 9E-4 and 9E-5). |
EA 0052:2014 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
I.S. EN 62271-204:2011 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGE ABOVE 52 KV (IEC 62271-204:2011 (EQV)) |
CEI 20-66 : 2010 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
I.S. HD 620:2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
EN 62271-204:2011 | High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV |
BS EN 62271-204:2011 | High-voltage switchgear and controlgear Rigid gas-insulated transmission lines for rated voltage above 52 kV |
UNE-HD 620-1:2010 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 1: General requirements. |
IEC 60230:1966 | Impulse tests on cables and their accessories |
IEC 62230:2006+AMD1:2013 CSV | Electric cables - Spark-test method |
EN 60230:2002 | Impulse tests on cables and their accessories |
EN 62230:2007/A1:2014 | ELECTRIC CABLES - SPARK-TEST METHOD |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.