• Shopping Cart
    There are no items in your cart

EN 50425:2008

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Switches for household and similar fixed electrical installations - Collateral standard - Fireman's switches for exterior and interior signs and luminaires

Superseded date

03-01-2012

Superseded by

EN 60669-2-6:2012

Published date

02-20-2008

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Definitions
4 General requirements
5 General notes on tests
6 Ratings
7 Classification
8 Marking
9 Checking of dimensions
10 Protection against electric shock
11 Provision for earthing
12 Terminals
13 Constructional requirements
14 Mechanism
15 Resistance to ageing, protection provided by enclosures of
   switches and resistance to humidity
16 Insulation resistance and electric strength
17 Temperature rise
18 Making and breaking capacity
19 Normal operation
20 Mechanical strength
21 Resistance to heat
22 Screws, current-carrying parts and connections
23 Creepage distances, clearances and distances through sealing
   compound
24 Resistance of insulating material to abnormal heat, to fire
   and to tracking
25 Resistance to rusting
26 EMC requirements
Annex ZA (normative) Normative references to international
                     publications with their corresponding European
                     publications
Annex ZB (normative) Special national conditions
Annex ZC (informative) A-deviations

This clause of Part 1 applies with the following modifications: Replacement of the first paragraph: This collateral standard applies to fireman's switches used for the breaking of the low voltage circuits for exterior and interior signs and luminaires e.g. neon signs for a.c. only with a rated voltage not exceeding 440 V and a rated current not exceeding 125 A. NOTE 1 The working voltage for the signs and luminous-discharge-tube installations is higher than 1 kV but lower than 10 kV and these should be in accordance with EN 50107 series. Renumbering of the subsequent notes. Replacement of the 6th paragraph and the new Note 6 by: Fireman’s switches complying with this standard are suitable for use between –20 °C and +70 °C. NOTE 6 Fireman’s switches are designed for overvoltage category III and used in environment of pollution degree 2 according to EN 60664-1.

Committee
CLC/TC 23BX
DevelopmentNote
To be read in conjunction with EN 60669-1. (02/2008)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

Standards Relationship
VDE 0632-425 : 2008 Identical
NBN EN 50425 : 2008 Identical
NEN EN 50425 : 2008 Identical
SN EN 50425 : 2008 Identical
NF EN 50425 : 2008 Identical
BS EN 50425:2008 Identical
DIN EN 50425 : 2008 Identical
CEI EN 50425 : 2008 Identical
PN EN 50425 : 2008 Identical
UNE-EN 50425:2008 Identical
I.S. EN 50425:2008 Identical

EN 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
EN 50107-1 : 2002 AMD 1 2004 SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1 KV BUT NOT EXCEEDING 10 KV - PART 1: GENERAL REQUIREMENTS
2006/95/EC : 2006 DIRECTIVE 2006/1995/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 12 DECEMBER 2006 ON THE HARMONISATION OF THE LAWS OF MEMBER STATES RELATING TO ELECTRICAL EQUIPMENT DESIGNED FOR USE WITHIN CERTAIN VOLTAGE LIMITS (CODIFIED VERSION) (TEXT WITH EEA RELEVANCE)
EN 60669-2-4:2005 Switches for household and similar fixed electrical installations - Part 2-4: Particular requirements - Isolating switches
IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
IEC 60669-1:2017 Switches for household and similar fixed-electrical installations - Part 1: General requirements
IEC 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
IEC 60669-2-4:2004 Switches for household and similar fixed electrical installations - Part 2-4: Particular requirements - Isolating switches
EN 50107-2:2005 Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV - Part 2: Requirements for earth-leakage and open-circuit protective devices
HD 384.5.51 : 200S2 ELECTRICAL INSTALLATION OF BUILDINGS - PART 5: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - CHAPTER 51: COMMON RULES

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.