• Shopping Cart
    There are no items in your cart

EN 50329:2003/A1:2010

Current

Current

The latest, up-to-date edition.

RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS

Amendment of

EN 50329:2003

Published date

05-21-2010

Sorry this product is not available in your region.

Introduction
1 General
2 General requirements for a traction transformer
3 Directly-coupled traction transformer
4 Traction converter transformers
5 Auxiliary transformers
6 Traction auto-transformers
Annex A (informative) - Preferred duty classes
Annex B (normative) - Insulation characteristics and test
        values
Annex C (normative) - Determination of losses and of
        equivalent current by means of alternative methods
Annex E (informative) - Evaluation of traction transformer
        behaviour
Annex F (informative) - Information for tenders and orders
Bibliography

Specifies specific characteristics of traction transformers, used in traction substation or along the track for the supply of power to a.c. and d.c. traction systems or to provide power to auxiliary services.

Committee
TC 9X
DevelopmentNote
Partially supersedes EN 60146-1-3 (05/2003) Supersedes HD 591. (03/2007)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

S.R. CLC/TR 50646:2015 RAILWAY APPLICATION - FIXED INSTALLATIONS - SPECIFICATION FORREVERSIBLE D.C. SUBSTATIONS
I.S. EN 50327:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
BS EN 50328:2003 Railway applications. Fixed installations. Electronic power convertors for substations
PD IEC TS 60076-20:2017 Power transformers Energy efficiency
I.S. EN 50123-1:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - GENERAL
CEI EN 50328 : 2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS
PD CLC/TR 50646:2015 Railway Application. Fixed Installations. Specification for reversible d.c. substations
I.S. EN 50123-4:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
I.S. EN 50328:2007 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS
BS EN 50588-1:2017 Medium power transformers 50 Hz, with highest voltage for equipment not exceeding 36 kV General requirements
BS EN 50123-2:2003 Railway applications. Fixed installations. D.C. switchgear D.C. circuit breakers
EN 50123-7-2:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-2: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating current transducers and other current measuring devices
BS EN 50123-1:2003 Railway applications. Fixed installations. D.C. switchgear General
UNE-EN 50633:2017 Railway applications - Fixed installations - Protection principles for AC and DC electric traction systems
IEC 62590:2010 Railway applications - Fixed installations - Electronic power converters for substations
I.S. EN 50123-7-2:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING CURRENT TRANSDUCERS AND OTHER CURRENT MEASURING DEVICES
BS EN 50123-7-1:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Measurement, control and protection devices for specific use in d.c. traction systems. Application guide
BS EN 50633:2016 Railway applications. Fixed installations. Protection principles for AC and DC electric traction systems
I.S. EN 50588-1:2017 MEDIUM POWER TRANSFORMERS 50 HZ, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS
BS EN 50327:2003 Railway applications. Fixed installations. Harmonisation of the rated values for converter groups and tests on converter groups
CEI EN 50123-1 : 2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 1: GENERAL
IEC 62589:2010 Railway applications - Fixed installations - Harmonisation of the rated values for converter groups and tests on converter groups
IEC 61992-1:2006+AMD1:2014 CSV Railway applications - Fixed installations - DC switchgear - Part 1:General
I.S. EN 50123-3:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
EN 50588-1:2017 Medium power transformers 50 Hz, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
I.S. EN 50123-2:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - D.C. CIRCUIT BREAKERS
I.S. EN 50123-7-3:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING VOLTAGE TRANSDUCERS AND OTHER VOLTAGE MEASURING DEVICES
EN 50123-7-3:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-3: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating voltage transducers and other voltage measuring devices
BS EN 50123-7-3:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating voltage transducers and other voltage measuring devices
BS EN 50123-7-2:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating current transducers and other current measuring devices
EN 50328 : 2003 COR 2006 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS
EN 50327 : 2003 AMD 1 2005 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
EN 50633:2016 Railway applications - Fixed installations - Protection principles for AC and DC electric traction systems
EN 50123-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 1: General
EN 50123-7-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-1: Measurement, control and protection devices for specific use in d.c. traction systems - Application guide
EN 50123-4:2003/A1:2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
EN 50123-2:2003 Railway applications - Fixed installations - D.C. switchgear - Part 2: D.C. circuit breakers
CLC/TR 50646:2015 Railway Application - Fixed Installations - Specification for reversible d.c. substations
EN 50123-3:2003/A1:2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES

HD 428.4 : 200S1 THREE-PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 TO 2500 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - DETERMINATION OF THE POWER RATING OF A TRANSFORMER LOADED WITH NON-SINUSODIAL CURRENTS
IEC 60076-7:2005 Power transformers - Part 7: Loading guide for oil-immersed power transformers
R009-002 : 1998 RAILWAY APPLICATIONS - GUIDE FOR THE USE OF THE TERMINOLOGY FOR TESTING PROCEDURES
EN 50122-1:2011/A4:2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK
EN 61000-2-12:2003 Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
EN 60076-5:2006 Power transformers - Part 5: Ability to withstand short-circuit
EN 60076-11:2004 Power transformers - Part 11: Dry-type transformers
IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
HD 538.3 : 200S1 THREE-PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 2500 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 3: DETERMINATION OF THE POWER RATING OF A TRANSFORMER LOADED WITH NON-SINUSOIDAL CURRENT
EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
EN 50125-2:2002/corrigendum:2010 RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS
IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
EN 50327 : 2003 AMD 1 2005 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
IEC 60076-1:2011 Power transformers - Part 1: General
EN 50152-1 : 2012 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
EN 50163 : 2004 COR 2013 RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS
IEC 60905:1987 Loading guide for dry-type power transformers
EN 50121-5:2017 Railway applications - Electromagnetic compatibility - Part 5: Emission and immunity of fixed power supply installations and apparatus
IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
EN 61378-1:2011 Convertor transformers - Part 1: Transformers for industrial applications
EN 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
EN 50328 : 2003 COR 2006 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS
IEC 61378-1:2011 Converter transformers - Part 1: Transformers for industrial applications

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.