EN 50305:2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Railway applications - Railway rolling stock cables having special fire performance - Test methods
03-26-2020
07-19-2002
Introduction
1 Scope
2 Normative references
3 Definitions
4 Applicability, sampling, test-piece preparation and
test conditions
4.1 Applicable tests
4.2 Classification of tests
4.3 Sampling
4.4 Test-piece preparation
4.5 Test conditions
5 Mechanical tests
5.1 Impact test at low temperature
5.2 Abrasion resistance
5.3 Notch propagation
5.4 Pliability
5.5 Strippability and adhesion of insulation
5.6 Dynamic cut-through
6 Electrical tests
6.1 Electrical resistance of conductors
6.2 Voltage test on completed cable
6.3 Voltage test on sheath
6.4 Insulation resistance
6.5 Spark test
6.6 Surface resistance
6.7 D.C. stability
6.8 Dielectric strength
7 Ageing and thermal tests
7.1 Compatibility
7.2 Long term ageing for insulation
7.3 Long term ageing for sheath
7.4 Ozone resistance
7.5 Pressure test at high temperature
7.6 Shrinkage test for insulation
7.7 Stress cracking test
8 Tests in fluids, including water
8.1 Mineral and fuel oil resistance
8.2 Acid and alkali resistance
8.3 Water absorption of sheath
9 Reaction to fire tests
9.1 Flame propagation
9.2 Toxicity
10 Miscellaneous tests
10.1 Durability of marking
10.2 Blocking of cores
Annex A (informative) List of other test methods applicable
to rolling stock cables
Annex B (informative) Procedure for checking the efficacy
of the method pf spark testing (with reference to 6.5)
Annex C (informative) Long term ageing test - Significance
and use
Annex D (informative) Illustration of an Arrhenius plot
Annex E (normative) Analysis methods for toxicity
This standard specifies special test methods applicable to cables, and their constituent insulating and sheathing materials, for use in railway rolling stock. Such cables are specified in the various parts of EN 50264 and EN 50306.Other test methods required for railway rolling stock cables and their insulating and sheathing materials are listed in Annex A.
Committee |
CLC/TC 20
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NF EN 50305 : 2002 | Identical |
NBN EN 50305 : 2003 | Identical |
NEN EN 50305 : 2002 | Identical |
I.S. EN 50305:2002 | Identical |
PN EN 50305 : 2010 | Identical |
SN EN 50305 : 2002 | Identical |
VDE 0260-305 : 2003 COR 1 2008 | Identical |
DIN EN 50305 : 2003 COR 1 2008 | Identical |
BS EN 50305:2002 | Identical |
UNE-EN 50305:2015 | Identical |
CEI EN 50305 : 2003 | Identical |
UNE-EN 50305:2002 | Identical |
CEI UNI EN 45545-2 : 2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAUVIOR OF MATERIALS AND COMPONENTS |
BS EN 50264-2-2:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Multicore cables |
I.S. EN 50264-3-2:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES |
I.S. EN 45545-2:2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
BS EN 45545-2 : 2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
I.S. EN 50264-3-1:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES |
I.S. EN 50306-4:2002 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 4: MULTICORE AND MULTIPAIR CABLE STANDARD WALL SHEATHED |
XP CEN/TS 45545-2 : 2009 XP | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
I.S. EN 50264-3:2002 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - STANDARD WALL - PART 3: MULTICORE CABLES |
EN 60695-9-2:2014 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
EN 50264-2-1:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables |
EN 60695-7-2:2011 | Fire hazard testing - Part 7-2: Toxicity of fire effluent - Summary and relevance of test methods |
EN 50382-1 : 2008 AMD 1 2013 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
EN 50264-1:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements |
EN 50264-3-2:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables |
EN 50264-2:2002 | Railway applications - Railway rolling stock cables having special fire performance - Standard wall - Part 2: Single core cables |
BS EN 50382-1 : 2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
UNE-EN 50264-3-2:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables |
BS EN 50382-2 : 2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C |
05/30133180 DC : 0 | EN 50382-1 - RAILWAY APPLICATIONS - HIGH TEMPERATURE POWER CABLES FOR RAILWAY ROLLING STOCK AND HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
CEI EN 50306-4 : 2003 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 4: MULTICORE AND MULTIPAIR CABLES STANDARD WALL SHEATHED |
05/30137080 DC : 0 | EN 50264-2-2 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATON - MULTICORE CABLES |
05/30137085 DC : 0 | EN 50264-3-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES |
BS EN 50264-2-1:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Single core cables |
BS EN 50355:2013 | Railway applications. Railway rolling stock cables having special fire performance. Guide to use |
I.S. EN 50264-2-1:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES |
I.S. EN 50264-2:2002 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - STANDARD WALL - PART 2: SINGLE CORE CABLES |
I.S. EN 60695-7-2:2011 | FIRE HAZARD TESTING - PART 7-2: TOXICITY OF FIRE EFFLUENT - SUMMARY AND RELEVANCE OF TEST METHODS (IEC 60695-7-2:2011) |
S.R. CEN/TS 45545-2:2009 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
I.S. EN 60695-9-2:2014 | FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS |
IEC 60695-7-2:2011 | Fire hazard testing - Part 7-2: Toxicity of fire effluent - Summary and relevance of test methods |
EN 50306-1:2002 | Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements |
EN 45545-2:2013+A1:2015 | Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behaviour of materials and components |
CEI EN 60695-7-2 : 2013 | FIRE HAZARD TESTING - PART 7-2: TOXICITY OF FIRE EFFLUENT - SUMMARY AND RELEVANCE OF TEST METHODS |
UNI CEI EN 45545-2 : 2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAUVIOR OF MATERIALS AND COMPONENTS |
10/30216687 DC : 0 | BS EN 45545-2 - RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
13/30277639 DC : 0 | BS EN 50355 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE |
CEI EN 50264-2-1 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES |
CEI EN 50355 : 2014 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE |
CEI EN 50264-3-1 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES |
BS EN 50306-2:2002 | Railway applications. Railway rolling stock cables having special fire performance. Thin wall Single core cables |
CEI EN 50306-2 : 2003 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 2: SINGLE CORE CABLES |
PREN 50355 : DRAFT 2012 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE |
CEI EN 50264-2-2 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES |
05/30136253 DC : 0 | EN 50264-2-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES |
UNE-EN 50264-2-1:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables |
I.S. EN 50382-2:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C |
BS EN 50264-2:2002 | Railway applications. Railway rolling stock cables having special fire performance. Standard wall Single core cables |
CEI EN 50264-3-2 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES |
UNE-EN 60695-9-2:2014 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
IEC 60695-9-2:2014 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
UNE-EN 50264-1:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 1: General requirements |
CEI EN 50306-3 : 2003 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 3: SINGLE CORE AND MULTICORE CABLES (PAIRS, TRIPLES AND QUADS) SCREENED AND THIN WALL SHEATHED |
BS EN 50264-3:2002 | Railway applications. Railway rolling stock cables having special fire performance. Standard wall Multicore cables |
UNE-EN 50264-3-1:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables |
CEI EN 50306-1 : 2003 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 1: GENERAL REQUIREMENTS |
BS EN 50264-3-2:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Multicore cables |
BS EN 50264-3-1:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Single core cables |
BS EN 50306-1:2002 | Railway applications. Railway rolling stock cables having special fire performance. Thin wall General requirements |
DIN EN 45545-2:2016-02 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
05/30136249 DC : 0 | EN 50264-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
UNI CEI CEN/TS 45545-2 : 2009 | RAILWAY APPLICATIONS - FIRE PROTECTION OF RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
BS EN 50306-4:2002 | Railway applications. Railway rolling stock cables having special fire performance. Thin wall Multicore and multipair cables standard wall sheathed |
05/30133183 DC : 0 | EN 50382-2 - RAILWAY APPLICATIONS - HIGH TEMPERATURE POWER CABLES FOR RAILWAY ROLLING STOCK AND HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREE C |
CEI EN 50264-1 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
BS EN 60695-7-2:2011 | Fire hazard testing Toxicity of fire effluent. Summary and relevance of test methods |
DD CEN/TS 45545-2:2009 | Railway applications. Fire protection on railway vehicles Requirements for fire behaviour of materials and components |
I.S. EN 50382-1:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
I.S. EN 50306-2:2002 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 2: SINGLE CORE CABLES |
I.S. EN 50264-1:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
I.S. EN 50306-1:2002 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 1: GENERAL REQUIREMENTS |
EN 50306-2:2002 | Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables |
BS EN 60695-9-2:2014 | Fire hazard testing Surface spread of flame. Summary and relevance of test methods |
EN 50306-3:2002 | Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 3: Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed |
EN 50306-4:2002 | Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 4: Multicore and multipair cables standard wall sheathed |
UNE-EN 60695-7-2:2012 | Fire hazard testing - Part 7-2: Toxicity of fire effluent - Summary and relevance of test methods |
EN 50355:2013 | Railway applications - Railway rolling stock cables having special fire performance - Guide to use |
05/30137088 DC : 0 | EN 50264-3-2 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATON WITH REDUCED DIMENSIONS - MULTICORE CABLES |
BS EN 50264-1:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance General requirements |
BS EN 50306-3:2002 | Railway applications. Railway rolling stock cables having special fire performance. Thin wall Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed |
UNE-EN 45545-2:2013 | Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behavior of materials and components |
UNE-EN 50264-2-2:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables |
I.S. EN 50264-2-2:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES |
I.S. EN 50306-3:2002 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 3: SINGLE CORE AND MULTICORE CABLES (PAIRS, TRIPLES AND QUADS) SCREENED AND THIN WALL SHEATHED |
I.S. EN 50355:2013 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - GUIDE TO USE |
CEN/TS 45545-2:2009 | Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behaviour of materials and components |
EN 50264-2-2:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables |
EN 50264-3-1:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables |
EN 50382-2:2008/A1:2013 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C |
EN 50264-3:2002 | Railway applications - Railway rolling stock cables having special fire performance - Standard wall - Part 3: Multicore cables |
EN 50266-2-4 : 2001 COR 2002 | COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-4: PROCEDURES - CATEGORY C |
IEC 60811-3-1:1985 | Common test methods for insulating and sheathing materials ofelectric cables - Part 3: Methods specific to PVC compounds -Section One: Pressure test at high temperature - Tests forresistance to cracking |
EN 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
EN 50306-1:2002 | Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements |
EN 60811-3-1 : 95 AMD 2 2001 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - METHODS SPECIFIC TO PVC COMPOUNDS - PRESSURE TEST AT HIGH TEMPERATURE - TESTS FOR RESISTANCE TO CRACKING |
EN 50267-1:1998 | Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 1: Apparatus |
ISO 6349:1979 | Gas analysis Preparation of calibration gas mixtures Permeation method |
EN 50264-1:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements |
IEC 60811-1-2:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods |
IEC 60811-1-1:1993+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties |
IEC 60811-1-3:1993+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test |
ISO 8458-2:2002 | Steel wire for mechanical springs — Part 2: Patented cold-drawn non-alloy steel wire |
IEC 60811-1-4:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
EN 60811-1-4:1995/A2:2001 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE |