EN 50288-7:2005
Current
The latest, up-to-date edition.
Multi-element metallic cables used in analogue and digital communication and control - Part 7: Sectional specification for instrumentation and control cables
09-30-2005
1 Scope
2 Normative references
3 Definitions, symbols and abbreviations
4 Cable construction
4.1 Conductor
4.2 Insulation
4.3 Cable elements
4.4 Identification of cabling elements
4.5 Screening of cabling elements
4.6 Cable make-up
4.7 Filling compound
4.8 Interstitial fillers
4.9 Screening of the cable core
4.10 Moisture barriers
4.11 Protective wrappings
4.12 Inner sheath
4.13 Bedding layers
4.14 Metallic protection
4.15 Integral suspension strand
4.16 Outer sheathing
4.17 Fauna protection
4.18 Chemical and/or environmental protection
4.18.1 Lead sheath
4.18.2 Multi-layer sheath
5 Test methods and requirements for completed
cables
5.1 Electrical tests
5.1.1 Low frequency and d.c. electrical
measurements
5.2 Mechanical tests
5.3 Environmental tests
5.4 Fire performance test methods
Annex A (normative) - Insulation thickness and concentricity -
Selection of samples and evaluation of results
Annex B (normative) - Copper braid screening
Annex C (normative) - Determination of cable dimensions
Annex D (informative) - Thermocouple extension and compensating
conductors
This sectional specification covers multi-element cables suitable for connecting instruments and control systems for analogue or digital signal transmission. They may or may not be screened and optionally may incorporate armouring and/or moisture or environmental protection layers. The cables shall have a mechanically robust construction and electrical transmission handling properties. The electrical, mechanical, transmission and environmental performance characteristics of the cables, related to their reference test methods are detailed. This sectional specification is to be read in conjunction with EN 50288-1, which contains the essential provisions for its application. Cables covered by this specification have maximum rated voltages of 90 V, 300 V and 500 V a.c. These cables shall not be connected directly to mains electricity supply or other low impedance sources. Multi-element cables for use in analogue, digital and control circuits are not designed to be used for power supply. These cables should be installed in accordance with the applicable local and national regulations. Cables intended to have limited circuit integrity in a fire are not covered by this specification, but they are however under consideration for future editions. There may be occasions when cables are required to have higher operating temperature ratings than those provided by using materials specified by the EN 50290 series. Suitable alternative materials are under consideration.
Committee |
CLC/TC 46X
|
DevelopmentNote |
To be read in conjunction with EN 50288-1. (10/2005)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
BS EN 50288-7:2005 | Identical |
VDE 0819-7 : 2006 COR 1 2009 | Identical |
I.S. EN 50288-7:0 | Identical |
PN EN 50288-7 : 2006 | Identical |
UNE-EN 50288-7:2011 | Identical |
NBN EN 50288-7 : 2006 | Identical |
SN EN 50288-7 : 2005 | Identical |
CEI EN 50288-7 : 2006 | Identical |
NEN EN 50288-7 : 2005 | Identical |
DIN EN 50288-7 : 2006 COR 1 2009 | Identical |
NF EN 50288-7 : 2006 | Identical |
UNE-EN 50288-7:2005 | Identical |
UNE-EN 50290-2-29:2016 | Communication cables - Part 2-29: Common design rules and construction - Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables |
CEI EN 50290-2-29 : 2002 | COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES |
EN 1366-11:2018 | Fire resistance tests for service installations - Part 11: Fire protective systems for cable systems and associated components |
EN 50290-2-29:2016 | Communication cables - Part 2-29: Common design rules and construction - Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables |
I.S. EN 50290-2-29:2016 | COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES |
PREN 1366-11 : DRAFT 2014 | FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 11: FIRE PROTECTIVE SYSTEMS FOR CABLE SYSTEMS AND ASSOCIATED COMPONENTS |
16/30336762 DC : 0 | BS EN 50290-2-29 - COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES |
IEEE 45.8-2016 | IEEE Recommended Practice for Electrical Installations on Shipboard--Cable Systems |
14/30299756 DC : 0 | BS EN 1366-11 - FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 11: FIRE PROTECTIVE SYSTEMS FOR CABLE SYSTEMS AND ASSOCIATED COMPONENTS |
BS EN 50290-2-29:2016 | Communication cables Common design rules and construction. Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables |
PREN 50290-2-29 : DRAFT 2016 | COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES |
EN 10218-1:2012 | Steel wire and wire products - General - Part 1: Test methods |
IEC 60228:2004 | Conductors of insulated cables |
EN 10244-2:2009 | Steel wire and wire products - Non-ferrous metallic coatings on steel wire - Part 2: Zinc or zinc alloy coatings |
EN 50307:2002 | Lead and lead alloys - Lead and lead alloy sheaths and sleeves of electric cables |
IEC 60584-3:2007 | Thermocouples - Part 3: Extension and compensating cables - Tolerances and identification system |
EN 10257-1:2011 | Zinc or zinc alloy coated non-alloy steel wire for armouring either power cables or telecommunication cables - Part 1: Land cables |
EN 60708:2005/AC:2016-08 | LOW-FREQUENCY CABLES WITH POLYOLEFIN INSULATION AND MOISTURE BARRIER POLYOLEFIN SHEATH |
HD 383 : S2 AMD 2 | CONDUCTORS OF INSULATED CABLES - GUIDE TO THE DIMENSIONAL LIMITS OF CIRCULAR CONDUCTORS |
IEC 60189-2:2007 | Low-frequency cables and wires with PVC insulation and PVC sheath - Part 2: Cables in pairs, triples, quads and quintuples for inside installations |
IEC 60811-1-1:1993+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties |
IEC 60708:2005 | Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath |
EN 60811-1-1:1995/A1:2001 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES |
HD 446.3 : 200S1 | THERMOCOUPLES - EXTENSION AND COMPENSATING CABLES - TOLERANCES AND IDENTIFICATION SYSTEM |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.