Introduction
1 Scope
2 Normative references
3 Definitions and abbreviations
   3.1 Definitions
   3.2 Abbreviations
4 Equipment attributes
   4.1 General
   4.2 Functionality
5 CIE construction
6 Security grade
7 Environmental performance
   7.1 Requirements
   7.2 Environmental and EMC tests
8 Functional requirements
   8.1 Inputs
   8.2 Outputs
   8.3 Operation
   8.4 Processing
   8.5 Indication
   8.6 Notification outputs
   8.7 Tamper security (detection/protection)
   8.8 Interconnections
   8.9 Timing
   8.10 Event recording
   8.11 Power supply
9 Product documentation
   9.1 Installation and maintenance
   9.2 Operating instructions
10 Marking and labelling
11 Tests
   11.1 Test conditions
   11.2 Test procedures
   11.3 Reduced functional test
   11.4 Functional tests
   11.5 Access level
   11.6 Authorization requirements
   11.7 Operational tests
   11.8 Tamper security tests
   11.9 Substitution tests
   11.10 Testing of I&HAS timing performance
   11.11 Testing for interconnections
   11.12 Event log
   11.13 Marking and documentation
   11.14 Environmental and EMC tests
Annex A (informative) - Interconnection types
Annex B (informative) - Summary of timing
        requirements
Annex C (normative) - Use of non-I&HAS interface
Annex D (informative) - Summary of function cross
        references
Bibliography

This standard specifies the requirements, performance criteria and testing procedures for control and indicating equipment (CIE) intended for use in intrusion and hold-up alarm systems (I&HAS) installed in buildings. This document also applies to CIE to be used in IAS or HAS. The CIE may incorporate processing functions of other I&HAS components or its processing requirements may be distributed among such components. This standard specifies the requirements for CIE installed in buildings using specific or non-specific wired interconnections or wire-free interconnections. These requirements also apply to ACE that are installed inside or outside of the supervised premises and mounted in indoor or outdoor environments. Where CIE shares means of detection, interconnection, control, communication, processing and/or power supplies with other applications, these requirements apply to I&HAS functions only. This standard specifies performance requirements for CIE at each of the four security grades identified in the European Standard EN 50131-1, “Alarm Systems – Intrusion and hold-up systems – System requirements”. Requirements are also specified for four environmental classes covering applications for indoor and outdoor locations. This standard includes mandatory functions, which shall be provided on all CIE for the appropriate security grade, as well as optional functions that may additionally be provided. This standard does not deal with requirements for compliance with EU regulatory Directives, such as the EMC Directive, Low Voltage Directive, etc. except in that it specifies the equipment operating conditions for EMC susceptibility testing as required by EN 50130-4. NOTEIn this standard reference to the term “I&HAS” is used throughout, except where there is specific need to differentiate between the IAS and HAS portions of a system. The term is intended to include IAS and HAS when such systems are installed separately.

Committee
CLC/TC 79
DevelopmentNote
Supersedes CLC/TS 50131-3. (03/2009)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

I.S. EN 50131-10:2014 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 10: APPLICATION SPECIFIC REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT)
BS EN 50131-5-3:2017 Alarm systems. Intrusion systems Requirements for interconnections equipment using radio frequency techniques
BS EN 50131-1 : 2006 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
S.R. CLC/TS 50131-9:2014 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 9: ALARM VERIFICATION - METHODS AND PRINCIPLES
CLC/TS 50131-12:2016 Alarm systems - Intrusion and hold-up systems - Part 12: Methods and requirements for setting and unsetting of Intruder Alarm Systems (IAS)
EN 50131-10:2014 Alarm systems - Intrusion and hold-up systems - Part 10: Application specific requirements for Supervised Premises Transceiver (SPT)
S.R. CLC/TS 50131-12:2016 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 12: METHODS AND REQUIREMENTS FOR SETTING AND UNSETTING OF INTRUDER ALARM SYSTEMS (IAS)
10/30227151 DC : 0 BS EN 50131-9: 2010 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 9: ALARM VERIFICATION - METHODS AND PRINCIPLES
CEI CLC/TS 50131-5-4 : 2013 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 5-4: SYSTEM COMPATIBILITY TESTING FOR I&HAS EQUIPMENTS LOCATED IN SUPERVISED PREMISES
UNE-EN 50131-10:2014 Alarm systems - Intrusion and hold-up systems - Part 10: Application specific requirements for Supervised Premises Transceiver (SPT)
I.S. EN 50131-1:2006 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
BS EN 50131-10:2014 Alarm systems. Intrusion and hold-up systems Application specific requirements for Supervised Premises Transceiver (SPT)
15/30260747 DC : 0 BS EN 50131-5-3 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 5-3: REQUIREMENTS FOR INTERCONNECTIONS EQUIPMENT USING RADIO FREQUENCY TECHNIQUES
PREN 50131-9 : DRAFT 2010 ALARM SYSTEMS - INTRUSION AND HOLD UP SYSTEMS - PART 9: ALARM VERIFICATION - METHODS AND PRINCIPLES
TR 103 056 : 1.1.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SYSTEM REFERENCE DOCUMENT; SHORT RANGE DEVICES (SRD); TECHNICAL CHARACTERISTICS FOR SRD EQUIPMENT FOR SOCIAL ALARM AND ALARM APPLICATIONS
EN 50131-1:2006/A2:2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
CLC/TS 50131-9:2014 Alarm systems - Intrusion and hold-up systems - Part 9: Alarm verification - Methods and principles
PD CLC/TS 50131-9:2014 Alarm systems. Intrusion and hold-up systems Alarm verification. Methods and principles
PREN 50131-5-3 : DRAFT 2015 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 5-3: REQUIREMENTS FOR INTERCONNECTIONS EQUIPMENT USING RADIO FREQUENCY TECHNIQUES
UNE-EN 50131-5-3:2017 Alarm systems - Intrusion systems - Part 5-3: Requirements for interconnections equipment using radio frequency techniques
S.R. CLC/TS 50131-5-4:2012 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 5-4: SYSTEM COMPATIBILITY TESTING FOR I&HAS EQUIPMENTS LOCATED IN SUPERVISED PREMISES
UNE-CLC/TS 50131-5-4:2013 Alarm systems - Intrusion and hold-up systems - Part 5-4: System compatibility testing for I&HAS equipments located in supervised premises
UNE-EN 50131-1:2008 Alarm systems - Intrusion and hold-up systems -- Part 1: System requirements
CEI CLC/TS 50131-12 : 1ED 2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 12: METHODS AND REQUIREMENTS FOR SETTING AND UNSETTING OF INTRUDER ALARM SYSTEMS (IAS)
I.S. EN 50131-5-3:2017 ALARM SYSTEMS - INTRUSION SYSTEMS - PART 5-3: REQUIREMENTS FOR INTERCONNECTIONS EQUIPMENT USING RADIO FREQUENCY TECHNIQUES
EN 50131-5-3:2017 Alarm systems - Intrusion systems - Part 5-3: Requirements for interconnections equipment using radio frequency techniques
CLC/TS 50131-5-4:2012 Alarm systems - Intrusion and hold-up systems - Part 5-4: System compatibility testing for I&HAS equipments located in supervised premises

EN 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
CLC/TS 50398:2009 Alarm systems - Combined and integrated alarm systems - General requirements
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
EN 50131-1:2006/A2:2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
EN 50131-6:2017 Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 50131-5-3:2017 Alarm systems - Intrusion systems - Part 5-3: Requirements for interconnections equipment using radio frequency techniques
EN 50130-5:2011 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS