EN 50123-1:2003
Current
The latest, up-to-date edition.
Railway applications - Fixed installations - D.C. switchgear - Part 1: General
02-28-2003
1 Scope
2 Normative references
3 Definitions
3.1 General terms
3.2 Performance characteristics
3.3 Components
3.4 Terms relating to d.c. circuit breakers,
switch-disconnectors and associated relays
4 Service conditions and requirements
4.1 Environmental conditions
4.2 Insulation levels
5 Standard features and conventional assumptions
5.1 Standard features and conventional parameters
for the main circuit
5.2 Standard features for auxiliary and control
circuits
6 Temperature-rise limits
7 Tests
7.1 General
7.2 Test tolerances
7.3 Tests on movable devices
7.4 Temperature-rise test
7.5 Dielectric tests
7.6 Short circuit and load switching conditions
7.7 Verification of the behaviour during short-time
withstand current test
7.8 Verification of the manual control device for
sturdiness and position indicator reliability
Annex A (normative) Diagrams for tests
Annex B (normative) Environmental conditions for indoor
installations
Annex C (normative) Search of critical currents for d.c.
circuit breakers and switches
Annex D (informative) Recommended creepage distances
Annex E (informative) Determination of maximum energy
fault location
Bibliography
Figures
Tables
The EN 50123 series specifies requirements for d.c. switchgear and controlgear and is intended to be used in fixed electrical installations with nominal voltage not exceeding 3 000 V d.c., which supply electrical power to vehicles for public guided transport, i.e. railway vehicles, tramway vehicles, underground vehicles and trolley-buses.Part 1 specifies general requirements.The other parts are coveringPart 2D.C. circuit breakers,Part 3Indoor d.c. disconnectors, switch-disconnectors and earthing switches,Part 4Outdoor d.c. disconnectors, switch-disconnectors and earthing switches,Part 5Surge arresters and low voltage limiters for specific use in d.c. systems,Part 6 D.C. switchgear assemblies,Part 7 1Measurement, control and protection devices for specific use in d.c. traction systems – Application guide,Part 7 2Measurement, control and protection devices for specific use in d.c. traction systems – Isolating current transducers and other current measuring devices,Part 7 3Measurement, control and protection devices for specific use in d.c. traction systems –Isolating voltage transducers and other voltage measuring devices
Committee |
CLC/TC 9X
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
CEI EN 50123-1 : 2003 | Identical |
NEN EN 50123-1 : 2003 | Identical |
I.S. EN 50123-1:2003 | Identical |
NF EN 50123-1 : 2004 | Identical |
PN EN 50123-1 : 2003 | Identical |
SN EN 50123-1 : 2003 | Identical |
BS EN 50123-1:2003 | Identical |
DIN EN 50123-1 : 2003 COR 1 2004 | Identical |
UNE-EN 50123-1:2004 | Identical |
VDE 0115-300-1 : 2003 COR 1 2004 | Identical |
S.R. CLC/TR 50646:2015 | RAILWAY APPLICATION - FIXED INSTALLATIONS - SPECIFICATION FORREVERSIBLE D.C. SUBSTATIONS |
I.S. EN 50463-2:2017 | RAILWAY APPLICATIONS - ENERGY MEASUREMENT ON BOARD TRAINS - PART 2: ENERGY MEASURING |
NF EN 50123-2 : 2004 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 2: D.C. CIRCUIT BREAKERS |
13/30251586 DC : 0 | BS EN 50123-6:2003/AMD 1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 6: D.C. SWITCHGEAR ASSEMBLIES |
PREN 50463-2 : DRAFT 2015 | RAILWAY APPLICATIONS - ENERGY MEASUREMENT ON BOARD TRAINS - PART 2: ENERGY MEASURING |
CEI EN 50125-2 : 2003 | RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS |
15/30329546 DC : 0 | BS EN 50463-2 - RAILWAY APPLICATIONS - ENERGY MEASUREMENT ON BOARD TRAINS - PART 2: ENERGY MEASURING |
BS EN 50463-2:2017 | Railway applications. Energy measurement on board trains Energy measuring |
PD CLC/TR 50646:2015 | Railway Application. Fixed Installations. Specification for reversible d.c. substations |
CEI EN 50123-2 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 2: D.C. CIRCUIT BREAKERS |
EN 50388 : 2012 COR 2013 | RAILWAY APPLICATIONS - POWER SUPPLY AND ROLLING STOCK - TECHNICAL CRITERIA FOR THE COORDINATION BETWEEN POWER SUPPLY (SUBSTATION) AND ROLLING STOCK TO ACHIEVE INTEROPERABILITY |
CLC/TS 50544:2010 | Low voltage d.c. surge protective device for traction systems - Selection and application rules for surge arresters |
EN 50123-6 : 2003 AMD 1 2014 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 6: D.C. SWITCHGEAR ASSEMBLIES |
UNE-EN 50123-6:2004 | Railway applications - Fixed installations - D.C. switchgear -- Part 6: D.C. switchgear assemblies |
NF EN 50123-7-1 : 2004 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-1: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - APPLICATION GUIDE |
08/30191365 DC : DRAFT OCT 2008 | BS EN 50388 - RAILWAY APPLICATIONS - POWER SUPPLY AND ROLLING STOCK - TECHNICAL CRITERIA FOR THE COORDINATION BETWEEN POWER SUPPLY (SUBSTATION) AND ROLLING STOCK TO ACHIEVE INTEROPERABILITY |
BS EN 50526-2:2014 | Railway applications. Fixed installations. D.C. surge arresters and voltage limiting devices Voltage limiting devices |
PREN 50388-1 : DRAFT 2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS AND ROLLING STOCK - TECHNICAL CRITERIA FOR THE COORDINATION BETWEEN TRACTION POWER SUPPLY AND ROLLING STOCK TO ACHIEVE INTEROPERABILITY - PART 1: GENERAL |
S.R. CLC/TS 50544:2010 | LOW VOLTAGE D.C. SURGE PROTECTIVE DEVICE FOR TRACTION SYSTEMS - SELECTION AND APPLICATION RULES FOR SURGE ARRESTERS |
NF EN 50123-4 : 2004 AMD 1 2014 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
NF EN 50123-6 : 2004 AMD 1 2015 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 6: D.C. SWITCHGEAR ASSEMBLIES |
UNE-EN 50388:2013 | Railway Applications - Power supply and rolling stock - Technical criteria for the coordination between power supply (substation) and rolling stock to achieve interoperability |
UNE-EN 50633:2017 | Railway applications - Fixed installations - Protection principles for AC and DC electric traction systems |
I.S. EN 50388:2012 | RAILWAY APPLICATIONS - POWER SUPPLY AND ROLLING STOCK - TECHNICAL CRITERIA FOR THE COORDINATION BETWEEN POWER SUPPLY (SUBSTATION) AND ROLLING STOCK TO ACHIEVE INTEROPERABILITY |
DIN EN 50123-7-2 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING CURRENT TRANSDUCERS AND OTHER CURRENT MEASURING DEVICES |
NF EN 50123-7-2 : 2004 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING CURRENT TRANSDUCERS AND OTHER CURRENT MEASURING DEVICES |
DD CLC/TS 50544:2010 | Low voltage d.c. surge protective device for traction systems. Selection and application rules for surge arresters |
11/30250871 DC : 0 | BS EN 50388 - RAILWAY APPLICATIONS - POWER SUPPLY AND ROLLING STOCK - TECHNICAL CRITERIA FOR THE COORDINATION BETWEEN POWER SUPPLY (SUBSTATION) AND ROLLING STOCK TO ACHIEVE INTEROPERABILITY |
BS EN 50123-4 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
BS EN 50633:2016 | Railway applications. Fixed installations. Protection principles for AC and DC electric traction systems |
11/30213786 DC : 0 | BS EN 50463-2 - RAILWAY APPLICATIONS - ENERGY MEASUREMENT ON BOARD TRAINS - PART 2: ENERGY MEASURING |
CEI CLC/TS 50544 : 2011 | LOW VOLTAGE D.C. SURGE PROTECTIVE DEVICE FOR TRACTION SYSTEMS - SELECTION AND APPLICATION RULES FOR SURGE ARRESTERS |
I.S. EN 50123-5:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - SURGE ARRESTERS AND LOW-VOLTAGE LIMITERS FOR SPECIFIC USE IN D.C. SYSTEMS |
EN 50463-2:2017 | Railway applications - Energy measurement on board trains - Part 2: Energy measuring |
CEI EN 50388 : 2012 | RAILWAY APPLICATIONS - POWER SUPPLY AND ROLLING STOCK - TECHNICAL CRITERIA FOR THE COORDINATION BETWEEN POWER SUPPLY (SUBSTATION) AND ROLLING STOCK TO ACHIEVE INTEROPERABILITY |
BS EN 50123-5:2003 | Railway applications. Fixed installations. D.C. switchgear Surge arresters and low-voltage limiters for specific use in d.c. systems |
EN 50123-5:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 5: Surge arresters and low-voltage limiters for specific use in d.c. systems |
17/30356581 DC : 0 | BS EN 50388-1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS AND ROLLING STOCK - TECHNICAL CRITERIA FOR THE COORDINATION BETWEEN TRACTION POWER SUPPLY AND ROLLING STOCK TO ACHIEVE INTEROPERABILITY - PART 1: GENERAL |
04/30117663 DC : DRAFT AUG 2004 | EN 50388 - RAILWAY APPLICATIONS - POWER SUPPLY AND ROLLING STOCK - TECHNICAL CRITERIA FOR THE COORDINATION BETWEEN SUPPLY (SUBSTATION) AND ROLLING STOCK TO ACHIEVE INTEROPERABILITY |
CEI EN 50123-7-3 : 2003 | RAILWAY APPLICATIONS -FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS -ISOLATING VOLTAGE TRANSDUCERS AND OTHER VOLTAGE MEASURING DEVICES |
CEI EN 50123-7-2 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING CURRENT TRANSDUCERS AND OTHER CURRENT MEASURING DEVICES |
12/30235298 DC : DRAFT JAN 2012 | BS EN 50526-2 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SURGE ARRESTERS AND VOLTAGE LIMITING DEVICES - PART 2: VOLTAGE LIMITING DEVICES |
BS EN 50123-6 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 6: D.C. SWITCHGEAR ASSEMBLIES |
CEI EN 50463-2 : 2013 | RAILWAY APPLICATIONS - ENERGY MEASUREMENT ON BOARD TRAINS - PART 2: ENERGY MEASURING |
PREN 50388 : DRAFT 2011 | RAILWAY APPLICATIONS - POWER SUPPLY AND ROLLING STOCK - TECHNICAL CRITERIA FOR THE COORDINATION BETWEEN POWER SUPPLY (SUBSTATION) AND ROLLING STOCK TO ACHIEVE INTEROPERABILITY |
I.S. EN 50125-2:2003 | RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS |
UNE-EN 50526-2:2014 | Railway applications - Fixed installations - D.C. surge arresters and voltage limiting devices - Part 2: Voltage limiting devices |
EN 50125-2:2002/corrigendum:2010 | RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS |
ENV 50123-7-1 : 1998 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - APPLICATION GUIDE |
NF EN 50123-7-3 : 2004 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING VOLTAGE TRANSDUCERS AND OTHER VOLTAGE MEASURING DEVICES |
I.S. EN 50123-6:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 6: D.C. SWITCHGEAR ASSEMBLIES |
DD ENV 50123-7.1 : 1999 | RAILWAY APPLICATION - FIXED INSTALLATIONS - D.C. SWITCHGEAR - MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - APPLICATION GUIDE |
BS EN 50388:2012 | Railway Applications. Power supply and rolling stock. Technical criteria for the coordination between power supply (substation) and rolling stock to achieve interoperability |
BS EN 50125-2:2002 | Railway applications. Environmental conditions for equipment Fixed electrical installations |
NF EN 50123-3 : 2004 AMD 1 2014 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
CEI EN 50526-2 : 2014 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SURGE ARRESTERS AND VOLTAGE LIMITING DEVICES - PART 2: VOLTAGE LIMITING DEVICES |
I.S. EN 50526-2:2014 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SURGE ARRESTERS AND VOLTAGE LIMITING DEVICES - PART 2: VOLTAGE LIMITING DEVICES |
EN 50526-2:2014 | Railway applications - Fixed installations - D.C. surge arresters and voltage limiting devices - Part 2: Voltage limiting devices |
EN 50633:2016 | Railway applications - Fixed installations - Protection principles for AC and DC electric traction systems |
CLC/TR 50646:2015 | Railway Application - Fixed Installations - Specification for reversible d.c. substations |
IEC 60243-1:2013 | Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
EN 50124-2:2017 | Railway applications - Insulation coordination - Part 2: Overvoltages and related protection |
EN 60129:1994/A2:1996 | ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES |
HD 214 : 200S2 | RECOMMENDED METHOD FOR DETERMINING THE COMPARATIVE TRACKING INDEX OF SOLID INSULATING MATERIALS UNDER MOIST CONDITIONS |
EN 50122-1:2011/A4:2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK |
IEC 60050-811:1991 | International Electrotechnical Vocabulary (IEV) - Part 811: Electric traction |
IEC 60050-605:1983 | International Electrotechnical Vocabulary (IEV) - Part 605: Generation, transmission and distribution of electricity - Substations |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
EN 50122-2:2010 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 2: PROVISIONS AGAINST THE EFFECTS OF STRAY CURRENTS CAUSED BY D.C. TRACTION SYSTEMS |
EN 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
EN 60099-1:1994/A1:1999 | SURGE ARRESTERS - PART 1: NON-LINEAR RESISTOR TYPE GAPPED SURGE ARRESTERS FOR A.C. SYSTEMS |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
EN 60507:2014 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
EN 60298:1996/A11:1999 | A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
EN 50329:2003/A1:2010 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
EN 50125-2:2002/corrigendum:2010 | RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS |
IEC 60129:1984 | Alternating current disconnectors and earthing switches |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
EN 60694:1996/A2:2001 | COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS |
EN 50327 : 2003 AMD 1 2005 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS |
HD 566 : 200S1 | THERMAL EVALUATION AND CLASSIFICATION OF ELECTRICAL INSULATION |
IEC TS 61245:2015 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on d.c. systems |
IEC 60050-446:1983 | International Electrotechnical Vocabulary (IEV) - Part 446: Electrical relays |
IEC 60099-1:1991+AMD1:1999 CSV | Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
EN 50163 : 2004 COR 2013 | RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS |
EN 60243-1:2013 | ELECTRIC STRENGTH OF INSULATING MATERIALS - TEST METHODS - PART 1: TESTS AT POWER FREQUENCIES (IEC 60243-1:2013) |
IEC 61992-1:2006+AMD1:2014 CSV | Railway applications - Fixed installations - DC switchgear - Part 1:General |
HD 380 : 200S2 | TEST METHODS FOR EVALUATING RESISTANCE TO TRACKING AND EROSION OF ELECTRICAL INSULATING MATERIALS USED UNDER SEVERE AMBIENT CONDITIONS |
IEC 60587:2007 | Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion |
IEC 60947-2:2016 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
EN 60947-2:2017 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
EN 50328 : 2003 COR 2006 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS |
EN 50126 : 1999 | RAILWAY APPLICATIONS - THE SPECIFICATION AND DEMONSTRATION OF RELIABILITY, AVAILABILITY, MAINTAINABILITY AND SAFETY (RAMS) |
IEC 60298:1990 | A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.