• There are no items in your cart

EN 50065-4-3:2003

Current

Current

The latest, up-to-date edition.

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 4-3: Low voltage decoupling filter - Incoming filter

Published date

01-23-2003

Sorry this product is not available in your region.

1 Scope
2 Normative references
3 Classification
   3.1 Type 1
   3.2 Type 2
   3.3 Type 3
4 Incoming filter electrical characteristics
   4.1 Over voltage
   4.2 EMC
   4.3 Operating frequency range
   4.4 Impedance
   4.5 Transfer function
Figures
Table 1

This standard applies to incoming filters used to control the coupling of signals between the utility area and the consumer area (see Figure 1). The standard defines•the minimum impedance in the relevant frequency band(s) at both Utility port and Consumer port,•the minimum attenuation of unwanted signals transmitted from the utility side to the consumer side and vice versa,•the transmission characteristics:-operating frequency domain for both utility side and consumer side,-attenuation between the utility side and the consumer side and vice versa,-impedance at the utility side and at the consumer side.This standard applies to incoming filters designed for and used in single or multiphase installations.

Committee
CLC/TC 219
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

CEI CLC/TR 50412-1 : 2008 POWER LINE COMMUNICATION APPARATUS AND SYSTEMS USED IN LOW-VOLTAGE INSTALLATIONS IN THE FREQUENCY RANGE 1,6 MHZ TO 30 MHZ - PART 1: GENERAL
CEI CWA 50487 : 2006 SMARTHOUSE CODE OF PRACTICE
S.R. CLC/TR 50627:2015 STUDY REPORT ON ELECTROMAGNETIC INTERFERENCE BETWEEN ELECTRICAL EQUIPMENT/SYSTEMS IN THE FREQUENCY RANGE BELOW 150 KHZ
CLC/TR 50627:2015 Study Report on Electromagnetic Interference between Electrical Equipment/Systems in the Frequency Range Below 150 kHz
PD CLC/TR 50627:2015 Study Report on Electromagnetic Interference between Electrical Equipment/Systems in the Frequency Range Below 150 kHz
CLC/TR 50412-1:2007 Power line communication apparatus and systems used in low-voltage installations in the frequency range 1,6 MHz to 30 MHz - Part 1: General
S.R. CLC/TR 50412-1:2007 POWER LINE COMMUNICATION APPARATUS AND SYSTEMS USED IN LOW-VOLTAGE INSTALLATIONS IN THE FREQUENCY RANGE 1,6 MHZ TO 30 MHZ - PART 1: GENERAL

EN 50065-4-1:2001 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 4-1: Low voltage decoupling filters - Generic specification
EN 50065-2-2:2003/A1:2005/corrigendum Oct. 2006 SIGNALING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 2-2: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 95 KHZ TO 148,5 KHZ AND INTENDED FOR USE IN INDUSTRIAL ENVIRONMENTS
EN 50065-2-1 : 2003 AMD 1 2005 SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 2-1: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 95 KHZ TO 148,5 KHZ AND INTENDED FOR USE IN RESIDENTIAL, COMMERCIAL AND LIGHT INDUSTRIAL ENVIRONMENTS
EN 50065-4-2 : 2001 AMD 2 2005 SIGNALLING ON LOW VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 4-2: LOW VOLTAGE DECOUPLING FILTERS - SAFETY REQUIREMENTS
EN 50065-2-3 : 2003 AMD 1 2005 SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148.5 KHZ - PART 2-3: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 3 KHZ TO 95 KHZ AND INTENDED FOR USE BY ELECTRICITY SUPPLIERS AND DISTRIBUTORS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.