EN 2714-004:2006
Current
The latest, up-to-date edition.
Aerospace series - Cables, electrical, single and multicore for general purpose - Operating temperatures between - 55 °C and 260 °C - Part 004: Screened (braided) and jacketed, ink jet printable - Product standard
08-23-2006
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Materials and construction
5 Required characteristics
6 Quality assurance
7 Designation
8 Identification and marking
9 Packaging, labelling and delivery lengths
10 Technical specification
This standard specifies the characteristics of ink jet printable, single and multicore screened (braided) and jacketed electrical cables for use in the on-board electrical systems of aircraft, at operating temperatures between 55 °C and 260 °C.It shall also be possible to mark these cables by hot stamp printing. These markings shall be in accordance with EN 3838.This standard is not valid for new study.
Committee |
ASD-STAN
|
DevelopmentNote |
Supersedes PREN 2714-004 (10/2006)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NBN EN 2714-004 : 2006 | Identical |
BS EN 2714-004:2006 | Identical |
NF EN 2714-004 : A2007 | Identical |
NS EN 2714-004 : 1ED 2006 | Identical |
I.S. EN 2714-004:2007 | Identical |
UNI EN 2714-004 : 2008 | Identical |
PN EN 2714-004 : 2006 | Identical |
DIN EN 2714-004:2007-10 | Identical |
SN EN 2714-004 : 2008 | Identical |
UNE-EN 2714-004:2006 | Identical |
NEN EN 2714-004 : 2006 | Identical |
I.S. EN 2714-002:2016 | AEROSPACE SERIES - CABLES, ELECTRICAL, SINGLE AND MULTICORE FOR GENERAL PURPOSE - OPERATING TEMPERATURES BETWEEN -55 DEGREES C AND 260 DEGREES C - PART 002: SCREENED AND JACKETED - GENERAL |
14/30314192 DC : 0 | BS EN 2714-002 - AEROSPACE SERIES - CABLES, ELECTRICAL, SINGLE AND MULTICORE FOR GENERAL PURPOSE - OPERATING TEMPERATURES BETWEEN -55 DEGREES C AND 260 DEGREES C - PART 002: SCREENED AND JACKETED - GENERAL |
PREN 2714-002 : 200P6 | AEROSPACE SERIES - CABLES, ELECTRICAL, SINGLE AND MULTICORE FOR GENERAL PURPOSE - OPERATING TEMPERATURES BETWEEN -55 DEGREES C AND 260 DEGREES C - PART 002: SCREENED AND JACKETED - GENERAL |
EN 2714-002:2016 | Aerospace series - Cables, electrical, single and multicore for general purpose - Operating temperatures between - 55 °C and 260 °C - Part 002: Screened and jacketed - General |
BS EN 2714-002:2016 | Aerospace series. Cables, electrical, single and multicore for general purpose. Operating temperatures between - 55 °C and 260 °C Screened and jacketed. General |
EN 3475-401:2002 | Aerospace series - Cables, electrical, aircraft use - Test Methods - Part 401: Accelerated ageing |
EN 3475-504:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 504: Torsion |
EN 3475-703:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 703: Permanence of manufacturer's marking |
EN 3475-409:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 409: Air-excluded ageing |
EN 3475-302:2006 | Aerospace series - Cable, electrical, aircraft use - Test methods - Part 302: Voltage proof test |
EN 3475-411:2014 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 411: Resistance to fluids |
EN 3475-202:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 202: Mass |
EN 3475-507:2007 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 507: Adherence of plating |
EN 3475-502:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 502: Notch propagation |
EN 3475-405:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 405: Bending at ambient temperature |
EN 2267-003:2005 | Aerospace series - Cables, electrical, for general purpose - Operating temperatures between - 55 °C and 260 °C - Part 003: Ink jet printable - Product standard |
EN 2235:2015 | Aerospace series - Single and multicore electrical cables, screened and jacketed - Technical specification |
EN 3475-410:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 410: Thermal endurance |
EN 3475-506:2007 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 506: Plating continuity |
EN 3475-305:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 305: Overload resistance |
EN 2083:2001 | Aerospace series - Copper and copper alloys conductors for electrical cables - Product standard |
EN 3475-602:2007 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 602: Toxicity |
EN 3475-404:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 404: Thermal shock |
EN 3475-509:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 509: Solderability |
EN 3475-201:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 201: Visual examination |
EN 3475-505:2012 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 505: Tensile test on conductors and strands |
EN 3475-702:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 702: Screen pushback capability |
EN 3475-303:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 303: Insulation resistance |
EN 3475-601:2007 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 601: Smoke density |
EN 3475-304:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 304: Surface resistance |
EN 3475-503:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 503: Scrape abrasion |
EN 3475-301:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 301: Ohmic resistance per unit length |
EN 3475-403:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 403: Delamination and blocking |
EN 3475-402:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 402: Shrinkage and delamination |
EN 3475-100:2010 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 100: General |
EN 3475-203:2006 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 203: Dimensions |
PREN 3838 : 200P2 | AEROSPACE SERIES - REQUIREMENTS AND TESTS ON USER-APPLIED MARKINGS ON AIRCRAFT ELECTRICAL CABLES |
EN 3475-408:2005 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 408: Fire resistance |
EN 3475-501:2006 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 501: Dynamic cut-through |
EN 3475-406:2002 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 406: Cold bend test |
EN 3475-701:2017 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 701: Strippability and adherence of insulation to the conductor |
EN 3475-508:2007 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 508: Plating thickness |
EN 3475-407:2009 | Aerospace series - Cables, electrical, aircraft use - Test methods - Part 407: Flammability |
EN 2714-002:2016 | Aerospace series - Cables, electrical, single and multicore for general purpose - Operating temperatures between - 55 °C and 260 °C - Part 002: Screened and jacketed - General |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.