EN 1859:2009+A1:2013
Current
The latest, up-to-date edition.
Chimneys - Metal chimneys - Test methods
04-03-2013
Foreword
1 Scope
2 Normative references
3 Definitions
4 Test methods for metal chimney products
5 Test report
Annex A (normative) - Method for measuring ambient
temperature
Annex B (normative) - Method for hot gas temperature
measurements
Annex C (informative) - Method for metal surface temperature
measurements
Annex D (normative) - Method for combustible wood surface
temperature measurements
Annex E (normative) - Locations of thermocouples for surface
temperature measurements
Annex F (normative) - Simplified calculation of thermal resistance
for circular flues
Annex G (informative) - Method for applying an evenly distributed
load (horizontal)
Annex H (informative) - Possible test sequence
Annex I (informative) - Techniques for flue gas volume flow
measurements
Bibliography
This European Standard describes test methods for metal chimney products.
Committee |
CEN/TC 166
|
DevelopmentNote |
Supersedes PREN 1859. (08/2009) 2009 Edition Re-Issued in April 2013 & incorporates AMD 1 2013. (04/2013)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Supersedes |
Standards | Relationship |
UNE-EN 1859:2010 | Identical |
I.S. EN 1859:2009 | Identical |
NBN EN 1859 : 2009 + A1 2013 | Identical |
UNI EN 1859 : 2013 | Identical |
NS EN 1859 : 2009 + A1 2013 | Identical |
NEN EN 1859 : 2009 + A1 2013 | Identical |
PN-EN 1859+A1:2013-09 | Identical |
BS EN 1859 : 2009 | Identical |
NF EN 1859 : 2009 + A1 2013 | Identical |
SN EN 1859 : 2009 + A1 2013 | Identical |
UNE-EN 1859:2010+A1:2013 | Identical |
BS EN 1859:2009+A1:2013 | Identical |
DIN EN 1859:2013-07 | Identical |
BS EN 1834-3:2000 | Identical |
02/103631 DC : DRAFT MAY 2002 | BS EN 14471 - CHIMNEYS - REQUIREMENTS AND TEST METHODS FOR SYSTEM CHIMNEYS WITH PLASTIC FLUE LINERS |
13/30272405 DC : 0 | BS EN 13384-1 REV - CHIMNEYS - THERMAL AND FLUID DYNAMIC CALCULATION METHODS - PART 1: CHIMNEYS SERVING ONE HEATING APPLIANCE |
04/30122093 DC : 0 | EN 14989-2 - CHIMNEYS AND AIR SUPPLY DUCT SYSTEMS FOR ROOM SEALED APPLIANCES - REQUIREMENTS AND TEST METHODS - PART 2: FLUE AND AIR SUPPLY DUCTS FOR INDIVIDUAL ROOM SEALED APPLIANCES |
PREN 13384-1 : DRAFT 2013 | CHIMNEYS - THERMAL AND FLUID DYNAMIC CALCULATION METHODS - PART 1: CHIMNEYS SERVING ONE HEATING APPLIANCE |
UNE-EN ISO 4528:2015 | Vitreous and porcelain enamel finishes - Guide to selection of test methods for vitreous and porcelain enamelled areas of articles (ISO 4528:2015) |
02/104192 DC : DRAFT JUN 2002 | EN 1856-1 - CHIMNEYS - REQUIREMENTS FOR METAL CHIMNEYS - PART 1: SYSTEM CHIMNEY PRODUCTS |
I.S. EN 14989-2:2007 | CHIMNEYS - REQUIREMENTS AND TEST METHODS FOR METAL CHIMNEYS AND MATERIAL INDEPENDENT AIR SUPPLY DUCTS FOR ROOM SEALED HEATING APPLICATIONS - PART 2: FLUE AND AIR SUPPLY DUCTS FOR ROOM SEALED APPLIANCES |
17/30332894 DC : 0 | BS EN 17082 - DOMESTIC AND NON-DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW |
DIN EN 13084-6:2016-02 | FREE-STANDING CHIMNEYS - PART 6: STEEL LINERS - DESIGN AND EXECUTION |
DIN EN 26:2015-08 | Gas-fired instantaneous water heaters for the production of domestic hot water |
DIN EN 777-3:2009-09 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON DOMESTIC USE - PART 3: SYSTEM F - SAFETY |
DIN EN 777-2:2009-09 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 2: SYSTEM E - SAFETY |
BS EN 1856-1:2009 | Chimneys. Requirements for metal chimneys System chimney products |
UNE-EN 14989-2:2011 | Chimneys - Requirements and test methods for metal chimneys and material independent air supply ducts for roomsealed heating applications - Part 2: Flue and air supply ducts for room sealed appliances |
BS EN 13084-6:2015 | Free-standing chimneys Steel liners. Design and execution |
BS EN 14989-1:2007 | Chimneys. Requirements and test methods for metal chimneys and material independent air supply ducts for roomsealed heating applications Vertical air/flue terminals for C6-type appliances |
I.S. EN 89:2015 | GAS-FIRED STORAGE WATER HEATERS FOR THE PRODUCTION OF DOMESTIC HOT WATER |
EN 12391-1:2003 | Chimneys - Execution standard for metal chimneys - Part 1: Chimneys for non-roomsealed heating appliances |
DIN EN 15502-2-1:2017-09 | Gas-fired central heating boilers - Part 2-1: Specific standard for type C appliances and type B2, B3 and B5 appliances of a nominal heat input not exceeding 1 000 kW (includes Amendment 1:2016) |
EN 13063-1:2005+A1:2007 | Chimneys - System chimneys with clay/ceramic flue liners - Part 1: Requirements and test methods for sootfire resistance |
EN 1319:2009 | Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW |
I.S. EN 16475-2:2017 | CHIMNEYS - ACCESSORIES - PART 2: CHIMNEY FANS - REQUIREMENTS AND TEST METHODS |
02/102804 DC : DRAFT APR 2002 | PREN 13063-1 - CHIMNEYS - SYSTEM CHIMNEYS WITH CLAY/CERAMIC FLUE LINERS - PART 1: REQUIREMENTS AND TEST METHODS FOR SOOTFIRE RESISTANCE |
PREN 416 : DRAFT 2017 | GAS-FIRED OVERHEAD RADIANT TUBE HEATERS AND RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - SAFETY AND ENERGY EFFICIENCY |
DIN EN 16475-2:2013-08 (Draft) | CHIMNEYS - ACCESSORIES - PART 2: CHIMNEY FANS - REQUIREMENTS AND TEST METHODS |
I.S. EN 483:2000 | GAS-FIRED CENTRAL HEATING BOILERS - TYPE C BOILERS OF NOMINAL HEAT INPUT NOT EXCEEDING 70 KW |
10/30218935 DC : 0 | BS EN 15502-2-1 - GAS-FIRED HEATING BOILERS - PART 2-1: SPECIFIC STANDARD FOR TYPE C APPLIANCES AND TYPE B[2], B[3] AND B[5] APPLIANCES OF A NOMINAL HEAT INPUT NOT EXCEEDING 1000 KW |
BS EN 16475-2:2017 | Chimneys. Accessories Chimney fans. Requirements and test methods |
I.S. EN 12391-1:2004 | CHIMNEYS - EXECUTION STANDARD FOR METAL CHIMNEYS - PART 1: CHIMNEYS FOR NON-ROOMSEALED HEATING APPLIANCES |
I.S. EN 1443:2003 | CHIMNEYS - GENERAL REQUIREMENTS |
PREN 17175 : DRAFT 2017 | GAS-FIRED OVERHEAD RADIANT STRIP HEATERS AND MULTI-BURNER CONTINUOUS RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - SAFETY AND ENERGY EFFICIENCY |
10/30219381 DC : 0 | BS EN 13084-7 - FREE-STANDING CHIMNEYS - PART 7: PRODUCT SPECIFICATIONS OF CYLINDRICAL STEEL FABRICATIONS FOR USE IN SINGLE WALL STEEL CHIMNEYS AND STEEL LINERS |
BS EN 50465:2015 | European product standard for combined heating power systems using gas fuel |
02/104193 DC : DRAFT JUN 2002 | PREN 13063-2 - CHIMNEYS - SYSTEM CHIMNEYS WITH CLAY/CERAMIC FLUE LINERS - PART 2: REQUIREMENTS AND TEST METHODS UNDER WET CONDITIONS |
EN 1443:2003 | Chimneys - General requirements |
I.S. EN ISO 4528:2015 | VITREOUS AND PORCELAIN ENAMEL FINISHES - GUIDE TO SELECTION OF TEST METHODS FOR VITREOUS AND PORCELAIN ENAMELLED AREAS OF ARTICLES (ISO 4528:2015) |
UNI EN 15287-2 : 2008 | CHIMNEYS - DESIGN, INSTALLATION AND COMMISSIONING OF CHIMNEYS - PART 2: CHIMNEYS FOR ROOM-SEALED APPLIANCES |
DIN EN 13384-1:2015-06 | CHIMNEYS - THERMAL AND FLUID DYNAMIC CALCULATION METHODS - PART 1: CHIMNEYS SERVING ONE HEATING APPLIANCE |
17/30353865 DC : 0 | BS EN 1443 - CHIMNEYS - GENERAL REQUIREMENTS |
PREN 50465 : DRAFT 2011 | GAS APPLIANCES - COMBINED HEAT AND POWER APPLIANCE OF NOMINAL HEAT INPUT INFERIOR OR EQUAL TO 70 KW |
EN 50465 : 2015 | GAS APPLIANCES - COMBINED HEAT AND POWER APPLIANCE OF NOMINAL HEAT INPUT INFERIOR OR EQUAL TO 70 KW |
BS EN 1443:2003 | Chimneys. General requirements |
I.S. EN 50465:2015 | GAS APPLIANCES - COMBINED HEAT AND POWER APPLIANCE OF NOMINAL HEAT INPUT INFERIOR OR EQUAL TO 70 KW |
DIN EN 1020:2010-05 | NON-DOMESTIC FORCED CONVECTION GAS-FIRED AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW INCORPORATING A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR OR COMBUSTION PRODUCTS |
DIN EN 1319:2010-06 | DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING, WITH FAN-ASSISTED BURNERS NOT EXCEEDING A NET HEAT INPUT OF 70 KW |
DIN EN 89:2015-08 | GAS-FIRED STORAGE WATER HEATERS FOR THE PRODUCTION OF DOMESTIC HOT WATER |
DIN EN 13084-8:2005-08 | FREE-STANDING INDUSTRIAL CHIMNEYS - PART 8: DESIGN AND EXECUTION OF MAST CONSTRUCTION WITH SATELLITE COMPONENTS |
DIN EN 1856-2:2009-09 | CHIMNEYS - REQUIREMENTS FOR METAL CHIMNEYS - PART 2: METAL FLUE LINERS AND CONNECTING FLUE PIPES |
BS EN 26:1998 | Gas fired instantaneous water heaters for the production of domestic hot water, fitted with atmospheric burners |
DIN EN 12391-1:2004-04 | CHIMNEYS - EXECUTION STANDARD FOR METAL CHIMNEYS - PART 1: CHIMNEYS FOR NON-ROOM SEALED HEATING APPLIANCES |
I.S. EN 1856-2:2009 | CHIMNEYS - REQUIREMENTS FOR METAL CHIMNEYS - PART 2: METAL FLUE LINERS AND CONNECTING FLUE PIPES |
I.S. EN 26:2015 | GAS-FIRED INSTANTANEOUS WATER HEATERS FOR THE PRODUCTION OF DOMESTIC HOT WATER |
DIN EN 1857:2010-08 | Chimneys - Components - Concrete flue liners |
I.S. EN 13063-1:2006 | CHIMNEYS - SYSTEM CHIMNEYS WITH CLAY/CERAMIC FLUE LINERS - PART 1: REQUIREMENTS AND TEST METHODS FOR SOOTFIRE RESISTANCE |
I.S. EN 13084-6:2015 | FREE-STANDING CHIMNEYS - PART 6: STEEL LINERS - DESIGN AND EXECUTION |
I.S. EN 1856-1:2009 | CHIMNEYS - REQUIREMENTS FOR METAL CHIMNEYS - PART 1: SYSTEM CHIMNEY PRODUCTS |
I.S. EN 1857:2010 | CHIMNEYS - COMPONENTS - CONCRETE FLUE LINERS |
07/30170129 DC : 0 | BS EN 1856-1 - CHIMNEYS - REQUIREMENTS FOR METAL CHIMNEYS - PART 1: SYSTEM CHIMNEY PRODUCTS |
BS EN 15287-2:2008 | Chimneys. Design, installation and commissioning of chimneys Chimneys for roomsealed appliances |
08/30194290 DC : 0 | BS EN 1856-1 - CHIMNEYS - REQUIREMENTS FOR METAL CHIMNEYS - PART 1: SYSTEM CHIMNEY PRODUCTS |
04/30115682 DC : DRAFT JUN 2004 | EN 14989-1 - CHIMNEYS AND AIR SUPPLY DUCT SYSTEMS FOR ROOMSEALED APPLIANCES - REQUIREMENTS AND TEST METHODS - PART 1: VERTICAL TERMINALS FOR C6-TYPE APPLIANCES |
DIN EN 15502-2-1:2013-01 | GAS-FIRED CENTRAL HEATING BOILERS - PART 2-1: SPECIFIC STANDARD FOR TYPE C APPLIANCES AND TYPE B2, B3 AND B5 APPLIANCES OF A NOMINAL HEAT INPUT NOT EXCEEDING 1000 KW |
BS EN ISO 4528:2015 | Vitreous and porcelain enamel finishes. Guide to selection of test methods for vitreous and porcelain enamelled areas of articles |
08/30183125 DC : 0 | BS EN 1857 - CHIMNEYS - COMPONENTS - CONCRETE FLUE LINERS |
05/30136031 DC : 0 | EN 15287-1 - CHIMNEYS - DESIGN, INSTALLATION AND COMMISSIONING OF CHIMNEYS - PART 1: CHIMNEYS FOR NON-ROOMSEALED HEATING APPLIANCES |
BS EN 15502-2-1 : 2012 | GAS-FIRED CENTRAL HEATING BOILERS - PART 2-1: SPECIFIC STANDARD FOR TYPE C APPLIANCES AND TYPE B2, B3 AND B5 APPLIANCES OF A NOMINAL HEAT INPUT NOT EXCEEDING 1000 KW |
PREN 26 : DRAFT 2012 | GAS-FIRED INSTANTANEOUS WATER HEATERS FOR THE PRODUCTION OF DOMESTIC HOT WATER |
PREN 1443 : DRAFT 2017 | CHIMNEYS - GENERAL REQUIREMENTS |
BS EN 13384-1 : 2002 | CHIMNEYS - THERMAL AND FLUID DYNAMIC CALCULATION METHODS - PART 1: CHIMNEYS SERVING ONE HEATING APPLIANCE |
DIN EN 1856-1:2009-09 | CHIMNEYS - REQUIREMENTS FOR METAL CHIMNEYS - PART 1: SYSTEM CHIMNEY PRODUCTS |
UNE-EN 13084-6:2016 | Free-standing chimneys - Part 6: Steel liners - Design and execution |
BS EN 89:2015 | Gas-fired storage water heaters for the production of domestic hot water |
UNE-EN 1856-1:2010 | Chimneys - Requirements for metal chimneys - Part 1: System chimney products |
BS EN 1020:2009 | Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products |
I.S. EN 777-4:2009 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 4: SYSTEM H - SAFETY |
I.S. EN 777-2:2009 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 2: SYSTEM E - SAFETY |
I.S. EN 777-3:2009 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON DOMESTIC USE - PART 3: SYSTEM F - SAFETY |
I.S. EN 1319:2009 | DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING, WITH FAN-ASSISTED BURNERS NOT EXCEEDING A NET HEAT INPUT OF 70 KW |
I.S. EN 621:2009 | NON-DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW, WITHOUT A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR AND/OR COMBUSTION PRODUCTS |
I.S. EN 778:2009 | DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 70 KW, WITHOUT A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR AND/OR COMBUSTION PRODUCTS |
I.S. EN 1020:2009 | NON-DOMESTIC FORCED CONVECTION GAS-FIRED AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW INCORPORATING A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR OR COMBUSTION PRODUCTS |
UNI EN 1856-1 : 2009 | CHIMNEYS - REQUIREMENTS FOR METAL CHIMNEYS - PART 1: SYSTEM CHIMNEY PRODUCTS |
UNI EN 1856-2 : 2009 | CHIMNEYS - REQUIREMENTS FOR METAL CHIMNEYS - PART 2: METAL FLUE LINERS AND CONNECTING FLUE PIPES |
UNI EN 1857 : 2010 | CHIMNEYS - COMPONENTS - CONCRETE FLUE LINERS |
EN 50465:2015 | Gas appliances - Combined heat and power appliance of nominal heat input inferior or equal to 70 kW |
UNI EN 778 : 2009 | DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 70 KW, WITHOUT A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR AND/OR COMBUSTION PRODUCTS |
UNI EN 777-4 : 2009 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 4: SYSTEM H - SAFETY |
UNI EN 1020 : 2009 | NON-DOMESTIC FORCED CONVECTION GAS- FIRED AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW INCORPORATING A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR OR COMBUSTION PRODUCTS |
UNI EN 1319 : 2010 | DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING, WITH FAN- ASSISTED BURNERS NOT EXCEEDING A NET HEAT INPUT OF 70 KW |
UNI EN 621 : 2010 | NON-DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW, WITHOUT A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR AND/OR COMBUSTION PRODUCTS |
UNI EN 777-2 : 2009 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 2: SYSTEM E - SAFETY |
UNI EN 777-3 : 2009 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 3: SYSTEM F - SAFETY |
BS EN 14989-2:2007 | Chimneys. Requirements and test methods for metal chimneys and material independent air supply ducts for roomsealed heating applications Flue and air supply ducts for room sealed appliances |
13/30272402 DC : 0 | BS EN 16475-3 - CHIMNEYS - ACCESSORIES - PART 3: DRAUGHT REGULATORS AND STANDSTILL OPENING DEVICES - REQUIREMENTS AND TEST METHODS |
13/30275588 DC : 0 | BS EN ISO 4528 - VITREOUS AND PORCELAIN ENAMEL FINISHES - GUIDE TO SELECTION OF TEST METHODS FOR VITREOUS AND PORCELAIN ENAMELLED AREAS OF ARTICLES |
17/30363953 DC : 0 | BS EN 416 - GAS-FIRED OVERHEAD RADIANT TUBE HEATERS AND RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - SAFETY AND ENERGY EFFICIENCY |
12/30254956 DC : 0 | BS EN 26 - GAS-FIRED INSTANTANEOUS WATER HEATERS FOR THE PRODUCTION OF DOMESTIC HOT WATER |
DIN EN 15287-2:2008-06 | Chimneys - Design, installation and commissioning of chimneys - Part 2: Chimneys for roomsealed appliances |
07/30156246 DC : 0 | BS EN 1858 - CHIMNEYS - COMPONENTS - CONCRETE FLUE BLOCKS |
I.S. EN 15287-2:2008 | CHIMNEYS - DESIGN, INSTALLATION AND COMMISSIONING OF CHIMNEYS - PART 2: CHIMNEYS FOR ROOMSEALED APPLIANCES |
16/30344387 DC : 0 | BS EN 16475-1 - CHIMNEYS - ACCESSORIES - PART 1: CHIMNEY SILENCERS - REQUIREMENTS AND TEST METHODS |
17/30363959 DC : 0 | BS EN 17175 - GAS-FIRED OVERHEAD RADIANT STRIP HEATERS AND MULTI-BURNER CONTINUOUS RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - SAFETY AND ENERGY EFFICIENCY |
EN 13384-1:2015 | Chimneys - Thermal and fluid dynamic calculation methods - Part 1: Chimneys serving one heating appliance |
DIN EN 778:2010-03 | DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 70 KW, WITHOUT A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR AND/OR COMBUSTION PRODUCTS |
BS EN 778:2009 | Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 70 kW, without a fan to assist transportation of combustion air and/or combustion products |
BS EN 621:2009 | Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products |
UNE-EN 1857:2013 | Chimneys - Components - Concrete flue liners |
BS EN 777-2:2009 | Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use System E. Safety |
UNE-EN 13384-1:2016 | Chimneys - Thermal and fluid dynamic calculation methods - Part 1: Chimneys serving one heating appliance |
BS EN 1856-2:2009 | Chimneys. Requirements for metal chimneys Metal flue liners and connecting flue pipes |
BS EN 13084-8:2005 | Free-standing industrial chimneys Design and execution of mast construction with satellite components |
BS EN 1857 : 2003 | CHIMNEYS - COMPONENTS - CONCRETE FLUE LINERS |
BS EN 777-4:2009 | Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use System H. Safety |
ISO 4528:2015 | Vitreous and porcelain enamel finishes Guide to selection of test methods for vitreous and porcelain enamelled areas of articles |
UNE-EN 1020:2010 | Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products |
BS EN 483 : 2000 | GAS-FIRED CENTRAL HEATING BOILERS - TYPE C BOILERS OF NOMINAL HEAT INPUT NOT EXCEEDING 70 KW |
BS EN 13063-1:2005 | Chimneys. System chimneys with clay/ceramic flue liners Requirements and test methods for sootfire resistance |
BS EN 12391-1:2003 | Chimneys. Execution standard for metal chimneys Chimneys for non-roomsealed heating appliances |
UNE-EN 1856-2:2010 | Chimneys - Requirements for metal chimneys - Part 2: Metal flue liners and connecting flue pipes |
UNE-EN 89:2016 | Gas-fired storage water heaters for the production of domestic hot water |
UNE-EN 26:2016 | Gas-fired instantaneous water heaters for the production of domestic hot water |
UNE-EN 778:2010 | Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 70 kW, without a fan to assist transportation of combustion air and/or combustion products |
EN 89:2015 | Gas-fired storage water heaters for the production of domestic hot water |
EN 621:2009 | Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products |
EN 777-2:2009 | Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use - Part 2: System E - Safety |
EN ISO 4528:2015 | Vitreous and porcelain enamel finishes - Guide to selection of test methods for vitreous and porcelain enamelled areas of articles (ISO 4528:2015) |
EN 14989-2:2007 | Chimneys - Requirements and test methods for metal chimneys and material independent air supply ducts for roomsealed heating applications - Part 2: Flue and air supply ducts for room sealed appliances |
EN 14989-1:2007 | Chimneys - Requirements and test methods for metal chimneys and material independent air supply ducts for roomsealed heating applications - Part 1: Vertical air/flue terminals for C6-type appliances |
EN 15287-2:2008 | Chimneys - Design, installation and commissioning of chimneys - Part 2: Chimneys for roomsealed appliances |
EN 778:2009 | Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 70 kW, without a fan to assist transportation of combustion air and/or combustion products |
EN 1857:2010 | Chimneys - Components - Concrete flue liners |
EN 15502-2-1:2012+A1:2016 | Gas-fired central heating boilers - Part 2-1: Specific standard for type C appliances and type B2, B3 and B5 appliances of a nominal heat input not exceeding 1 000 kW |
EN 26:2015 | Gas-fired instantaneous water heaters for the production of domestic hot water |
EN 1856-2:2009 | Chimneys - Requirements for metal chimneys - Part 2: Metal flue liners and connecting flue pipes |
EN 1856-1:2009 | Chimneys - Requirements for metal chimneys - Part 1: System chimney products |
EN 16475-2:2017 | Chimneys - Accessories - Part 2: Chimney fans - Requirements and test methods |
EN 777-3:2009 | Multi-burner gas-fired overhead radiant tube heater systems for non domestic use - Part 3: System F - Safety |
EN 777-4:2009 | Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use - Part 4: System H - Safety |
PREN 13063-1 : DRAFT 2002 | CHIMNEYS - SYSTEM CHIMNEYS WITH CLAY/CERAMIC FLUE LINERS - PART 1: REQUIREMENTS AND TEST METHODS FOR SOOTFIRE RESISTANCE |
I.S. EN 13384-1:2015 | CHIMNEYS - THERMAL AND FLUID DYNAMIC CALCULATION METHODS - PART 1: CHIMNEYS SERVING ONE HEATING APPLIANCE |
11/30249911 DC : 0 | BS EN 50465 - GAS APPLIANCES - COMBINED HEAT AND POWER APPLIANCE OF NOMINAL HEAT INPUT INFERIOR OR EQUAL TO 70 KW |
I.S. EN 15502-2-1:2012 | GAS-FIRED CENTRAL HEATING BOILERS - PART 2-1: SPECIFIC STANDARD FOR TYPE C APPLIANCES AND TYPE B2, B3 AND B5 APPLIANCES OF A NOMINAL HEAT INPUT NOT EXCEEDING 1000 KW |
I.S. EN 13384-1:2015+A1:2019&LC:2019 | CHIMNEYS - THERMAL AND FLUID DYNAMIC CALCULATION METHODS - PART 1: CHIMNEYS SERVING ONE HEATING APPLIANCE |
DIN EN 777-4:2009-09 | MULTI-BURNER GAS-FIRED OVERHEAD RADIANT TUBE HEATER SYSTEMS FOR NON-DOMESTIC USE - PART 4: SYSTEM H - SAFETY |
BS EN 1319:2009 | Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW |
BS EN 777-3:2009 | Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use System F. Safety |
DIN EN 621:2010-04 | NON-DOMESTIC GAS-FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING NOT EXCEEDING A NET HEAT INPUT OF 300 KW, WITHOUT A FAN TO ASSIST TRANSPORTATION OF COMBUSTION AIR AND/OR COMBUSTION PRODUCTS |
EN 1020:2009 | Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products |
DIN EN 14989-2:2008-03 | Chimneys - Requirements and test methods for metal chimneys and material independent air supply ducts for roomsealed heating applications - Part 2: Flue and air supply ducts for room sealed appliances |
DIN EN 13063-1:2007-10 | CHIMNEYS - SYSTEM CHIMNEYS WITH CLAY/CERAMIC FLUE LINERS - PART 1: REQUIREMENTS AND TEST METHODS FOR SOOTFIRE RESISTANCE |
EN 13084-8:2005 | Free-standing industrial chimneys - Part 8: Design and execution of mast construction with satellite components |
DIN EN ISO 4528:2015-05 | Vitreous and porcelain enamel finishes - Guide to selection of test methods for vitreous and porcelain enamelled areas of articles (ISO 4528:2015) |
DIN EN 483:2000-06 | GAS-FIRED CENTRAL HEATING BOILERS - TYPE C BOILERS OF NOMINAL HEAT INPUT NOT EXCEEDING 70 KW |
EN 13084-6:2015 | Free-standing chimneys - Part 6: Steel liners - Design and execution |
DIN EN 14989-1:2007-05 | Chimneys - Requirements and test methods for metal chimneys and material independent air supply ducts for roomsealed heating applications - Part 1: Vertical air/flue terminals for C6-type appliances |
NS-EN 15502-2-1:2022+A1:2023 | Gas-fired central heating boilers - Part 2-1: Specific standard for type C appliances and type B2, B3 and B5 appliances of a nominal heat input not exceeding 1 000 kW |
EN 1856-2:2009 | Chimneys - Requirements for metal chimneys - Part 2: Metal flue liners and connecting flue pipes |
EN 13216-1:2004 | Chimneys - Test methods for system chimneys - Part 1: General test methods |
EN 60068-2-59:1993 | Environmental testing - Part 2: Test methods - Test Fe: Vibration - Sine beat method |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 1443:2003 | Chimneys - General requirements |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 1856-1:2009 | Chimneys - Requirements for metal chimneys - Part 1: System chimney products |
ISO 3966:2008 | Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes |
IEC 60068-2-59:1990 | Environmental testing. Part 2: Tests. Test Fe: Vibration - Sine-beat method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.