EN 16361:2013+A1:2016
Current
The latest, up-to-date edition.
Power operated pedestrian doors - Product standard, performance characteristics - Pedestrian doorsets, other than swing type, initially designed for installation with power operation
07-13-2016
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Testing, assessment and sampling methods
6 Assessment and verification of constancy of performance - AVCP
Annex A (normative) - Standards and draft standards on glass
Annex B (informative) - Summary of the characteristics
Annex C (informative) - Handling, installation, maintenance and care
Annex D (informative) - Summary of classification of characteristics
Annex E (informative) - Example of air permeability calculation'
Annex ZA (informative) - Relationship of this European Standard
with Regulation (EU) No. 305/2011
Annex ZB (informative) - Relationship between this European
Standard and the Essential Requirements of the EMC Directive
Bibliography
This European Standard specifies requirements and test/assessment/calculation methods for external and internal power operated pedestrian doorsets, other than swing type, initially designed for installation with power operation.Such doorset constructions may be operated electro-mechanically, electro-hydraulically or pneumatically.These doorsets include power operated pedestrian sliding doorsets, revolving doorsets, balanced (sliding/swing) doorsets and folding doorsets with one or more horizontally moving leaves.This European Standard applies to power operated pedestrian doorsets with flush or panelled leaves, complete with:-integral fanlights, if any;NOTE 1A fanlight is a panel over a door which is part of the doorset.-side panels that are contained within a single frame for inclusion in a single aperture, if any.The intended uses of the products covered by this European Standard are:-doorsets for external use in escape routes and other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use in construction works;-doorsets for internal use in escape routes, communication and other declared specific uses and/or uses subject to other specific requirements, in particular noise and safety-in-use in construction works;-doorsets for internal use in escape routes, communication and other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy and safety-in-use in construction works.The products covered by this European Standard are not assessed for structural applications of the building.This European Standard does not cover operation in environments where the electromagnetic disturbances are outside the range of those specified in EN 61000-6-2.This European Standard does not apply to:-external pedestrian doorsets according to EN 14351-1;-internal pedestrian doorsets according to prEN 14351-2;-fire resistance and/or smoke control characteristics according to EN 16034;-lifts doorsets;-vehicles doorsets;-doorsets used in industrial processes;-doorsets in partition walls;-doorsets outside the reach of people (such as crane gantry fences);-turnstiles;-platform doorsets.This European Standard does not cover special functions of doorsets (e.g. security, fire aspects in banks, airports, etc.).This European Standard does not deal with any specific requirements on noise emitted from power operated doorsets, other than swing type, initially designed for installation with power operation as their noise emission is not considered to be a relevant hazard.NOTE 2Noise emission of power operated doorsets, other than swing type, initially designed for installation with power operation is not a significant hazard for the users of these products. It is a comfort aspect.
Committee |
CEN/TC 33
|
DevelopmentNote |
Supersedes PREN 16361. (10/2013) 2013 Edition Re-Issued in July 2016 & incorporates AMD 1 2016. (07/2016)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
UNI EN 16361 : 2016 | Identical |
BS EN 16361 : 2013 | Identical |
NBN EN 16361 : 2013 | Identical |
DIN EN 16361 E : 2016 | Identical |
SN EN 16361 : 2016 | Identical |
PN EN 16361 : 2013 + A1 2016 | Identical |
UNI EN 16361 : 2013 | Identical |
NEN EN 16361 : 2013 + A1 2016 | Identical |
NS EN 16361 : 2013 + A1 2016 | Identical |
I.S. EN 16361:2013 | Identical |
DIN EN 16361:2013-12 | Identical |
NF EN 16361 : 2013 + A1 2016 | Identical |
UNE-EN 16361:2014+A1:2017 | Identical |
BS EN 16361:2013+A1:2016 | Identical |
UNE-EN 16361:2014 | Identical |
DIN EN 16361:2019-04 (Draft) | Identical |
DIN EN 16361:2016-12 | Identical |
BS EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows. Product standard, performance characteristics. Fire resisting and/or smoke control characteristics |
16/30333210 DC : DRAFT MAR 2016 | BS EN 13241-1 AMD 2 - INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND GATES - PART 1: PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS |
I.S. EN 16034:2014 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS |
UNI EN 16034 : 2014 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS |
EN 13241:2003+A2:2016 | Industrial, commercial, garage doors and gates - Product standard, performance characteristics |
PREN 14351-2 : DRAFT 2014 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS |
I.S. EN 14351-1:2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND/OR SMOKE LEAKAGE CHARACTERISTICS |
BS EN 13241 : 2003 | INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND GATES - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS |
UNE-EN 16034:2015 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
DIN EN 16034:2014-12 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTANCE AND/OR SMOKE CONTROL CHARACTERISTICS |
BS EN 14351-1 : 2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS |
EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
EN 14351-1:2006+A2:2016 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets |
14/30297827 DC : 0 | BS EN 14351-2 - WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS |
UNE-EN 14351-1:2006 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics |
EN 14321-2:2005 | Glass in building - Thermally toughened alkaline earth silicate safety glass - Part 2: Evaluation of conformity/Product standard |
EN 12210:2016 | Windows and doors - Resistance to wind load - Classification |
ISO 10140-2:2010 | Acoustics Laboratory measurement of sound insulation of building elements Part 2: Measurement of airborne sound insulation |
EN 61000-6-3:2007/A1:2011/AC:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
EN 1026:2016 | Windows and doors - Air permeability - Test method |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
EN 1027:2016 | Windows and doors - Water tightness - Test method |
305/2011 : 2011 AMD 2 2014 | REGULATION (EU) NO 305/2011 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 9 MARCH 2011 LAYING DOWN HARMONISED CONDITIONS FOR THE MARKETING OF CONSTRUCTION PRODUCTS AND REPEALING COUNCIL DIRECTIVE 89/106/EEC (TEXT WITH EEA RELEVANCE) |
EN 1627:2011 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification |
EN ISO 12543-2:2011 | Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:2011) |
ISO 10077-2:2017 | Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: Numerical method for frames |
EN 12207:2016 | Windows and doors - Air permeability - Classification |
EN 12211:2016 | Windows and doors - Resistance to wind load - Test method |
EN 12208:1999 | Windows and doors - Watertightness - Classification |
EN 14179-2:2005 | Glass in building - Heat soaked thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard |
ISO 12543-2:2011 | Glass in building Laminated glass and laminated safety glass Part 2: Laminated safety glass |
EN 12519:2004 | Windows and pedestrian doors - Terminology |
EN ISO 10077-2:2017 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames (ISO 10077-2:2017) |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
ISO 12567-1:2010 | Thermal performance of windows and doors Determination of thermal transmittance by the hot-box method Part 1: Complete windows and doors |
EN 1863-2:2004 | Glass in building - Heat strengthened soda lime silicate glass - Part 2: Evaluation of conformity/Product standard |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
EN 12150-2:2004 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard |
EN 13241-1:2003+A1:2011 | Industrial, commercial and garage doors and gates - Product standard - Part 1: Products without fire resistance or smoke control characteristics |
EN 1279-5:2005+A2:2010 | Glass in building - Insulating glass units - Part 5: Evaluation of conformity |
EN 1629:2011+A1:2015 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under dynamic loading |
EN ISO 10140-2:2010 | Acoustics - Laboratory measurement of sound insulation of building elements - Part 2: Measurement of airborne sound insulation (ISO 10140-2:2010) |
EN 13049:2003 | Windows - Soft and heavy body impact - Test method, safety requirements and classification |
ISO 9001:2015 | Quality management systems — Requirements |
EN 1630:2011+A1:2015 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts |
ISO 717-1:2013 | Acoustics Rating of sound insulation in buildings and of building elements Part 1: Airborne sound insulation |
EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
EN 14351-1:2006+A2:2016 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets |
PREN 14351-2 : DRAFT 2014 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS |
ISO 10077-1:2017 | Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General |
EN 1628:2011+A1:2015 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under static loading |
EN ISO 10077-1:2017 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General (ISO 10077-1:2017, Corrected version 2020-02) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.