EN 16009:2011
Current
The latest, up-to-date edition.
Flameless explosion venting devices
07-20-2011
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Types of flameless explosion venting devices
6 Testing of flameless explosion venting devices
7 Information for use
8 Marking
9 Packaging
Annex A (informative) - Examples/types of flameless
explosion venting devices
Annex B (informative) - Flameless venting example
Annex C (informative) - Flameless venting criteria
Annex D (informative) - Flameless venting - Pressurization
of the surrounding volume
Annex ZA (informative) - Relationship between this European
Standard and the Essential Requirements of EU
Directive 94/9/EC
Bibliography
This European Standard specifies the requirements for flameless explosion venting devices used to protect enclosures against the major effects of internal explosions arising from the rapid burning of suspended dust, vapour or gas contained within. It includes the requirements for the design, inspection, testing, marking, documentation, and packaging. This standard is applicable to flameless explosion venting devices which are put on the market as autonomous protective systems.Explosion venting devices are protective systems comprised of a pressure sensitive membrane fixed to and forming part of the structure that it protects. They are designed to intervene in the event of an explosion at a predetermined pressure, to immediately open a vent area sufficient to ensure that the maximum pressure attained by an explosion within the enclosure does not exceed the maximum pressure the structure is designed to withstand.Flameless explosion venting devices typically consist of an explosion venting device in combination with a flame quenching element to avoid the transmission of flames into the surroundings. They are used to allow explosion venting in situations where otherwise the hazards of flames and pressure resulting from the venting would harm personnel or damage structures.The application and specification of explosion venting devices is outlined for dust explosion protection in EN 14491 and for gas explosion protection in EN 14994.This standard covers the flameless explosion venting of dust, vapour and gas explosions.This standard does not cover details for the avoidance of ignition sources from detection devices or other parts of the flameless explosion venting devices.
Committee |
CEN/TC 305
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
PN EN 16009 : 2013 | Identical |
NF EN 16009 : 2011 | Identical |
BS EN 16009:2011 | Identical |
NBN EN 16009 : 2011 | Identical |
NS EN 16009 : 2011 | Identical |
NEN EN 16009 : 2011 | Identical |
I.S. EN 16009:2011 | Identical |
UNI EN 16009 : 2011 | Identical |
SN EN 16009:2011 | Identical |
UNE-EN 16009:2011 | Identical |
DIN EN 16009:2011-10 | Identical |
PNE-prEN 16009 | Identical |
FM 7730 : 2014 | EXPLOSION VENTING DEVICES |
UNI EN 13237 : 2012 | POTENTIALLY EXPLOSIVE ATMOSPHERES - TERMS AND DEFINITIONS FOR EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
16/30348296 DC : DRAFT DEC 2016 | BS EN 14460 - EXPLOSION RESISTANT EQUIPMENT |
EN 13237:2012 | Potentially explosive atmospheres - Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres |
EN 12779:2015 | Safety of woodworking machines - Chip and dust extraction systems with fixed installation - Safety requirements |
UNI EN 16447 : 2014 | EXPLOSION ISOLATION FLAP VALVES |
12/30267131 DC : 0 | BS EN 16447 - EXPLOSION ISOLATION FLAP VALVES |
DIN EN 14491:2012-10 | Dust explosion venting protective systems |
I.S. EN 13237:2012 | POTENTIALLY EXPLOSIVE ATMOSPHERES - TERMS AND DEFINITIONS FOR EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
I.S. EN 12779:2015 | SAFETY OF WOODWORKING MACHINES - CHIP AND DUST EXTRACTION SYSTEMS WITH FIXED INSTALLATION - SAFETY RELATED PERFORMANCES AND SAFETY REQUIREMENTS |
I.S. EN 14491:2012 | DUST EXPLOSION VENTING PROTECTIVE SYSTEMS |
VDI 2263 Blatt 8.2:2014-12 | Dust fires and dust explosions - Hazards - assessment - protective measures - Explosion suppression and combination of structural protective measures in elevators |
VDI 2263 Blatt 6:2017-08 | Dust fires and dust explosions - Hazards - assessment - protective measures - Dust fires and explosion protection in dust extracting installations |
PREN 12779 : DRAFT 2014 | SAFETY OF WOODWORKING MACHINES - CHIPS AND DUST EXTRACTION SYSTEMS WITH FIXED INSTALLATIONS - SAFETY REQUIREMENTS |
DIN EN 12779:2016-03 | Safety of woodworking machines - Chip and dust extraction systems with fixed installation - Safety requirements |
UNI EN 14491 : 2012 | DUST EXPLOSION VENTING PROTECTIVE SYSTEMS |
BS EN 16447:2014 | Explosion isolation flap valves |
14/30292850 DC : 0 | BS EN 12779 - SAFETY OF WOODWORKING MACHINES - CHIPS AND DUST EXTRACTION SYSTEMS WITH FIXED INSTALLATIONS - SAFETY REQUIREMENTS |
DIN EN 16447:2014-09 | EXPLOSION ISOLATION FLAP VALVES |
I.S. EN 14460:2018 | EXPLOSION RESISTANT EQUIPMENT |
I.S. EN 16447:2014 | EXPLOSION ISOLATION FLAP VALVES |
EN 14460:2018 | Explosion resistant equipment |
BS EN 14491:2012 | Dust explosion venting protective systems |
BS EN 12779:2015 | Safety of woodworking machines. Chip and dust extraction systems with fixed installation. Safety requirements |
BS EN 13237:2012 | Potentially explosive atmospheres. Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres |
EN 14491:2012 | Dust explosion venting protective systems |
EN 16447:2014 | Explosion isolation flap valves |
DIN EN 13237:2013-01 | POTENTIALLY EXPLOSIVE ATMOSPHERES - TERMS AND DEFINITIONS FOR EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
UNE-EN 12779:2016 | Safety of woodworking machines - Chip and dust extraction systems with fixed installation - Safety requirements |
EN 1127-1:2011 | Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
EN 14034-2:2006+A1:2011 | Determination of explosion characteristics of dust clouds - Part 2: Determination of the maximum rate of explosion pressure rise (dp/dt)max of dust clouds |
EN 13980:2002 | Potentially explosive atmospheres - Application of quality systems |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
EN 13463-1:2009 | Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements |
EN 14797:2006 | Explosion venting devices |
EN 13673-2:2005 | Determination of maximum explosion pressure and the maximum rate of pressure rise of gases and vapours - Part 2: Determination of the maximum rate of explosion pressure rise |
IEC 61241-0:2004 | Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements |
EN 13237:2012 | Potentially explosive atmospheres - Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres |
EN 14491:2012 | Dust explosion venting protective systems |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
ISO 4126-2:2003 | Safety devices for protection against excessive pressure Part 2: Bursting disc safety devices |
EN 62061:2005/A2:2015 | SAFETY OF MACHINERY - FUNCTIONAL SAFETY OF SAFETY-RELATED ELECTRICAL, ELECTRONIC AND PROGRAMMABLE ELECTRONIC CONTROL SYSTEMS (IEC 62061:2005/A2:2015) |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
ISO 16852:2016 | Flame arresters — Performance requirements, test methods and limits for use |
EN 14034-1:2004+A1:2011 | Determination of explosion characteristics of dust clouds - Part 1: Determination of the maximum explosion pressure pmax of dust clouds |
EN 61241-0:2006 | Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements |
EN ISO 13849-1:2015 | Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design (ISO 13849-1:2015) |
IEC 61241-2-1:1994 | Electrical apparatus for use in the presence of combustible dust - Part 2: Test methods - Section 1: Methods for determining the minimum ignition temperatures of dust |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 62061:2005+AMD1:2012+AMD2:2015 CSV | Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems |
ISO 13849-1:2015 | Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design |
EN 13821:2002 | Potentially explosive atmospheres - Explosion prevention and protection - Determination of minimum ignition energy of dust/air mixtures |
EN 14994:2007 | Gas explosion venting protective systems |
EN ISO 16852:2016 | Flame arresters - Performance requirements, test methods and limits for use (ISO 16852:2016) |
1994/9/EC : 1994 | DIRECTIVE 94/9/EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL OF 23 MARCH 1994 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES CONCERNING EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.