EN 15650:2010
Current
The latest, up-to-date edition.
Ventilation for buildings - Fire dampers
04-07-2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Fire damper requirements
5 Test methods
6 Evaluation of conformity
7 Marking and documentation
8 Product, installation and maintenance information (documentation)
Annex A (informative) - Typical fire damper descriptions
Annex B (normative) - Salt spray exposure test
Annex C (normative) - Cycling Tests
Annex D (informative) - Example of inspection and maintenance
procedure
Annex E (normative) - Factory Production Control - TEST PLAN
Annex ZA (informative) - Relationship between this European Standard
and the Essential Requirements of EU Directive (Construction
products Directive 89/106/EEC)
Bibliography
This European Standard applies to fire dampers that are to be used in conjunction with fire separating elements to maintain fire compartments. This standard specifies requirements and gives reference to the test methods defined for fire dampers, which are intended to be installed in Heating, Ventilating and Air Conditioning (HVAC) installations in buildings. All fire dampers close automatically in response to raised temperatures indicating fire. Details are given for the provision of evaluation of conformity and marking of fire dampers. To avoid duplication reference is made to a variety of other standards. To this end it is advised to read this standard in conjunction with EN 1366-2 and EN 1363-1 for details of the fire resistance testing and EN 13501-3 for classification.Fire dampers meeting requirements of this standard may be considered suitable for both ducted and unducted applications.This standard has not considered in detail the detrimental and/or corrosive effects that may be caused by chemical processes present in the atmosphere, which are drawn through the system intentionally or inadvertently and therefore does not apply to fire dampers used in such applications. An indication of salt spray corrosion may be determined using the method described in Annex B.
Committee |
CEN/TC 156
|
DevelopmentNote |
To be read in conjunction with EN 1366-2, EN 1363-1 and EN 13501-3. (05/2010)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
UNE-EN 15650:2010 | Identical |
NF EN 15650 : 2010 | Identical |
DIN EN 15650:2010-09 | Identical |
NS EN 15650 : 2010 | Identical |
NBN EN 15650 : 2010 | Identical |
UNI EN 15650 : 2010 | Identical |
PN EN 15650 : 2010 | Identical |
SN EN 15650 : 2010 | Identical |
NEN EN 15650 : 2010 | Identical |
I.S. EN 15650:2010 | Identical |
BS EN 15650:2010 | Identical |
93/68/EEC : 1993 AMD 2 1998 | COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC |
EN 12101-2:2017 | Smoke and heat control systems - Part 2: Natural smoke and heat exhaust ventilators |
EN ISO 5135:1998 | Acoustics - Determination of sound power levels of noise from air-terminal devices, air-terminal units, dampers and valves by measurement in a reverberation room (ISO 5135:1997) |
89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
EN 12101-3:2015 | Smoke and heat control systems - Part 3: Specification for powered smoke and heat control ventilators (Fans) |
EN 13501-4:2016 | Fire classification of construction products and building elements - Part 4: Classification using data from fire resistance tests on components of smoke control systems |
ISO 13943:2017 | Fire safety — Vocabulary |
EN ISO 9002:1994/AC:1997 | QUALITY SYSTEMS - SPECIFICATION FOR PRODUCTION AND INSTALLATION |
ISO 9002:1994 | Quality systems — Model for quality assurance in production, installation and servicing |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
ISO 5135:1997 | Acoustics Determination of sound power levels of noise from air-terminal devices, air-terminal units, dampers and valves by measurement in a reverberation room |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 13501-3:2005+A1:2009 | Fire classification of construction products and building elements - Part 3: Classification using data from fire resistance tests on products and elements used in building service installations: fire resisting ducts and fire dampers |
EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
ISO 9001:2015 | Quality management systems — Requirements |
EN 1363-1:2012 | Fire resistance tests - Part 1: General Requirements |
EN 1366-2:2015 | Fire resistance tests for service installations - Part 2: Fire dampers |
EN 1751:2014 | Ventilation for buildings - Air terminal devices - Aerodynamic testing of damper and valves |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
ISO 10294-4:2001 | Fire resistance tests Fire dampers for air distribution systems Part 4: Test of thermal release mechanism |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.