Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Units
6 Information and requirements to be agreed
   and documented
   6.1 General
   6.2 Information to be provided by the purchaser
   6.3 Information to be provided by the designer
7 Applicable standards
8 Loads
   8.1 General
   8.2 Contents
   8.3 Tank structure
   8.4 Roof
   8.5 Equipment loads
   8.6 Access
   8.7 Environmental
   8.8 Ancillary items
9 Design
   9.1 General
   9.2 Steel
   9.3 Tank
   9.4 Openings
   9.5 Effects of accidents
10 Vitreous enamel coating
   10.1 Vitreous enamel
   10.2 Coating
   10.3 Vitreous enamel quality
   10.4 Protection during shipping
   10.5 Maintenance
11 Installation
   11.1 General guidance
   11.2 Foundations
   11.3 Inspection of the vitreous enamel coating
        at the construction site
12 Disinfection
Bibliography

This European Standard establishes the requirement for the design and use of vitreous enamel coated bolted cylindrical steel tanks for the storage or treatment of water or municipal or industrial effluents and sludges.This European Standard applies to the design of the tank and any associated roof and gives guidance on the requirements for the design of the foundation.This European Standard applies where:a)the tank is cylindrical and symmetrical on plan and is mounted on a load-bearing base substantially at or above ground level;b)the multiple of the tank diameter in meters and the wall height in meters has a value within the range 5 to 500;c)the tank diameter does not exceed 100 m, and the total wall height does not exceed 50 m;d)the stored material has the characteristics of a liquid exerting negligible friction force in the tank wall; the stored material may be undergoing treatment as part of a municipal or industrial effluent treatment process;e)the internal pressure above the liquid does not exceed 50 kPa and the internal partial vacuum above the liquid does not exceed 10 kPa;f)the walls of the tank are vertical;g)the floor of the tank is substantially flat at its intersection with the wall; the floor of the tank may have a rise or fall built in to allow complete emptying of the tank contents. The slope should not exceed 1:100;h)there is negligible inertial and impact load due to tank filling;i)the minimum thickness of the tank shell is 1,5 mm;j)the material used for the manufacture of the steel sheets is carbon steel; (tanks constructed of sheets made from aluminium or stainless steel are outside the scope of this European Standard),k)the temperature of the tank wall during operation is within the range - 50 °C to + 100 °C under all operating conditions.This European Standard also gives details of procedures to be followed during site installation and for inspection and maintenance of the installed tank.It does not appl

Committee
CEN/TC 262
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
NBN EN 15282 : 2007 Identical
NEN EN 15282 : 2007 Identical
PN EN 15282 : 2007 Identical
NEN EN 15382 : 2018 Identical
NS EN 15282 : 1ED 2007 Identical
BS EN 15282:2007 Identical
SN EN 15282 : 2007 Identical
NF EN 15282 : 2007 Identical
I.S. EN 15282:2007 Identical
UNE-EN 15282:2009 Identical
DIN EN 15282 E : 2007 Identical
UNI EN 15282 : 2007 Identical
DIN EN 15282:2007-06 Identical

ANSI/AWWA D103 : 2009 FACTORY-COATED BOLTED CARBON STEEL TANKS FOR WATER STORAGE
EN 10149-1:2013 Hot rolled flat products made of high yield strength steels for cold forming - Part 1: General technical delivery conditions
EN 14483-3:2004 Vitreous and porcelain enamels - Determination of resistance to chemical corrosion - Part 3: Determination of resistance to chemical corrosion by alkaline liquids using a hexagonal vessel
EN 101 : 1991 CERAMIC TILES - DETERMINATION OF SCRATCH HARDNESS OF SURFACE ACCORDING TO MOHS
EN ISO 8289:2001 Vitreous and porcelain enamels - Low voltage test for detecting and locating defects (ISO 8289:2000)
BS 7793-1:1995 Vitreous enamel coatings for use on bolted steel panels Specification for coatings on bolted steel panels for use in agricultural slurry tanks
BS 6399-3(1988) : 1988 LOADING FOR BUILDINGS - PART 3: CODE OF PRACTICE FOR IMPOSED ROOF LOADS
EN 10111:2008 Continuously hot rolled low carbon steel sheet and strip for cold forming - Technical delivery conditions
BS 5502-50(1993) : 1993 BUILDINGS AND STRUCTURES FOR AGRICULTURE - PART 50: CODE OF PRACTICE FOR DESIGN, CONSTRUCTION AND USE OF STORAGE TANKS AND RECEPTION PITS FOR LIVESTOCK SLURRY
BS 5395-3:1985 Stairs, ladders and walkways Code of practice for the design of industrial type stairs, permanent ladders and walkways
ISO 4532:1991 Vitreous and porcelain enamels Determination of the resistance of enamelled articles to impact Pistol test
EN 14483-2:2004 Vitreous and porcelain enamels - Determination of resistance to chemical corrosion - Part 2: Determination of resistance to chemical corrosion by boiling acids, neutral liquids and/or their vapours
ISO 4528:2015 Vitreous and porcelain enamel finishes Guide to selection of test methods for vitreous and porcelain enamelled areas of articles
EN 14430:2004 Vitreous and porcelain enamels - High voltage test
EN 14483-4:2004 Vitreous and porcelain enamels - Determination of resistance to chemical corrosion - Part 4: Determination of resistance to chemical corrosion by alkaline liquids using a cylindrical vessel
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
ISO 2747:1998 Vitreous and porcelain enamels Enamelled cooking utensils Determination of resistance to thermal shock
ISO 6370-2:2011 Vitreous and porcelain enamels Determination of the resistance to abrasion Part 2: Loss in mass after sub-surface abrasion
ISO 15686-1:2011 Buildings and constructed assets — Service life planning — Part 1: General principles and framework
ISO 9001:2015 Quality management systems — Requirements
ISO 2178:2016 Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method
EN 14483-1:2004 Vitreous and porcelain enamels - Determination of resistance to chemical corrosion - Part 1: Determination of resistance to chemical corrosion by acids at room temperature
ISO 8289:2000 Vitreous and porcelain enamels Low voltage test for detecting and locating defects
ICC 2009 INTERNATIONAL BUILDING CODE : 2009 INTERNATIONAL BUILDING CODE
BS 7793-2:1996 Vitreous enamel coatings for use on bolted steel panels Specification for coatings on bolted steel panels for use in industrial liquid storage tanks
BS 5502-22(2003) : 2003 BUILDINGS AND STRUCTURES FOR AGRICULTURE - PART 22: CODE OF PRACTICE FOR DESIGN, CONSTRUCTION AND LOADING
BS 7885:1997 Code of practice for safe entry into silos
EN 1998-4:2006 Eurocode 8 - Design of structures for earthquake resistance - Part 4: Silos, tanks and pipelines
EN ISO 2178:2016 Non-magnetic coatings on magnetic substrates - Measurement of coating thickness - Magnetic method (ISO 2178:2016)
EN 10209:2013 Cold rolled low carbon steel flat products for vitreous enamelling - Technical delivery conditions

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.