EN 15269-20:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 20: Smoke control for hinged and pivoted steel, timber and metal framed glazed doorsets
10-03-2020
09-23-2009
Foreword
Introduction
1 Scope
2 Normative references
3 Definitions
4 Determination of the field of extended
application
4.1 General
4.2 Procedure for evaluation
4.3 Procedure for maximum field of extended
application
4.4 Interpretation of test results
5 Extended application report
6 Classification report
Annex A (normative) - Construction parameter
variations
Annex B (normative) - Arrangements for doorsets
incorporating side and/or
overpanels
Bibliography
This Part of (pr/Fpr)EN 15269, which should be read in conjunction with FprEN 15269-1, covers hinged and pivoted steel doorsets, hinged and pivoted timber doorsets (including timber framed glazed doorsets) and hinged and pivoted metal framed glazed doorsets of single or double-leaf construction. The document prescribes the methodology for extending the application of test results obtained from test(s) conducted in accordance with EN 1634-3.NOTE It is anticipated that the above scope will be extended to cover other product types when the relevant test information and expertise become available.Subject to the completion of the appropriate test or tests, the extended application may cover Ambient Temperature Smoke Control (Sa) and Medium Temperature Smoke Control (Sm) classifications and all or some of the following variations:- glazed elements, louvres and/or vents;- side, transom or overpanels;- items of building hardware;- decorative finishes;- intumescent, smoke, draught or acoustic seals;- alternative supporting construction(s).
Committee |
CEN/TC 127
|
DevelopmentNote |
To be read in conjunction with PREN 15269-1. (10/2009)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
ONORM EN 15269-20 : 2009 | Identical |
DS EN 15269-20 : 2009 | Identical |
DIN EN 15269-20:2017-08 (Draft) | Identical |
NBN EN 15269-20 : 2010 | Identical |
NEN EN 15269-20 : 2009 | Identical |
NS EN 15269-20 : 2009 | Identical |
I.S. EN 15269-20:2009 | Identical |
PN EN 15269-20 : 2010 | Identical |
UNI EN 15269-20 : 2009 | Identical |
UNE-EN 15269-20:2010 | Identical |
BS EN 15269-20:2009 | Identical |
NF EN 15269-20 : 2013 | Identical |
DIN EN 15269-20:2009-12 | Identical |
15/30302476 DC : 0 | BS EN 13501-2 - FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES |
EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
I.S. EN 13501-2:2016 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES |
16/30340523 DC : 0 | BS EN 17020-4 - EXTENDED APPLICATION OF TEST RESULTS ON DURABILITY OF SELFCLOSING FOR DOORSETS AND OPENABLE WINDOWS - PART 4: DURABILITY OF SELF-CLOSING OF FIRE RESISTANCE HINGED AND PIVOTED METAL FRAMED GLAZED DOORSETS AND OPENABLE WINDOWS |
11/30239430 DC : 0 | BS EN 1191 - WINDOWS AND DOORS - RESISTANCE TO REPEATED OPENING AND CLOSING - TEST METHOD |
BS EN 13501-2 : 2007 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES |
PREN 13501-2 : DRAFT 2015 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES |
PREN 1191 : DRAFT 2011 | WINDOWS AND DOORS - RESISTANCE TO REPEATED OPENING AND CLOSING - TEST METHOD |
EN 1125:2008 | Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods |
ISO 13943:2017 | Fire safety — Vocabulary |
EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
EN 1634-2:2008 | Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 2: Fire resistance characterisation test for elements of building hardware |
PREN 15269-1 : DRAFT 2017 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 1: GENERAL REQUIREMENTS |
EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
EN 1363-1:2012 | Fire resistance tests - Part 1: General Requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.