EN 14384:2005
Current
The latest, up-to-date edition.
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Design requirements
4.1 Dimensions
4.2 Shell
4.3 Elastomers
4.4 Obturator - main valve
4.5 Materials including lubricants in contact with
water intended for human consumption
4.6 Leaktightness and mechanical strength
4.7 Components of the operating system
4.8 Closing direction
4.9 Opening turns
4.10 Resistance of the hydrant to operating loads
4.11 Operating mechanism
4.12 Inlet connections
4.13 Outlets
4.14 Drainage and venting systems
4.15 Security housing
4.16 Internal and external corrosion resistance
4.17 Colour
4.18 Resistance to disinfection products
4.19 Hydrants for non-potable water systems
4.20 Hydraulic characteristics
5 Test methods
5.1 General
5.2 General dimensions
5.3 Flow characteristics
6 Designation, marking and additional data
6.1 Designation
6.2 Marking of hydrants
6.3 Additional hydrant data
7 Evaluation of conformity
7.1 General
7.2 Initial type testing
7.3 Factory product control (FPC)
Annex ZA (informative) Clauses of this European Standard
addressing the provisions of the EU
Construction Products Directive
(89/106/EEC)
ZA.1 Scope and relevant clauses
ZA.2 Procedure for the attestation of conformity of
pillar fire hydrants
ZA.3 CE marking
ZA.4 Certificate and Declaration of Conformity
Bibliography
This European Standard specifies the minimum requirements, test methods, marking and evaluation of conformity for pillar hydrants for fire fighting purposes:to be installed in a water distribution system;sizes DN 80, DN 100 and DN 150;suitable for an allowable operating pressure, PFA, of PN 16 with or without drain facility;having vertical or horizontal, flanged, socket or spigot inlet;with one or two outlets and having outlets to national requirements;globe (screw down) or gate valve type.This European Standard also provides for the evaluation of conformity of the pillar fire hydrants to the requirements of this European Standard.This European Standard applies to fire hydrants for potable and non potable water and for filtered water. Additional requirements may apply for other liquids.Couplings connected to outlets are outside the scope of this European Standard and should conform to national requirements.Couplings connected to outlets are outside the scope of this document and shall conform to national requirements.
Committee |
CEN/TC 192
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
PN EN 14384 : 2005 | Identical |
NEN EN 14384 : 2005 | Identical |
NS EN 14384 : 1ED 2005 | Identical |
NF EN 14384 : 2006 | Identical |
UNI EN 14384 : 2006 | Identical |
DIN EN 14384:2005-10 | Identical |
UNE-EN 14384:2006 | Identical |
SS-EN 14384:2005 | Identical |
NBN EN 14384 : 2005 | Identical |
SN EN 14384:2005 | Identical |
BS EN 14384:2005 | Identical |
I.S. EN 14384:2005 | Identical |
I.S. EN 1074-6:2009 | VALVES FOR WATER SUPPLY - FITNESS FOR PURPOSE REQUIREMENTS AND APPROPRIATE VERIFICATION TESTS - PART 6: HYDRANTS |
DIN EN 1074-6:2009-03 | VALVES FOR WATER SUPPLY - FITNESS FOR PURPOSE REQUIREMENTS AND APPROPRIATE VERIFICATION TESTS - PART 6: HYDRANTS |
UNI EN 1074-6 : 2009 | VALVES FOR WATER SUPPLY - FITNESS FOR PURPOSE REQUIREMENTS AND APPROPRIATE VERIFICATION TESTS - PART 6: HYDRANTS |
UNE-EN 1074-6:2011 | Valves for water supply - Fitness for purpose requirements and appropriate verification tests - Part 6: Hydrants |
BS EN 1074-6:2008 | Valves for water supply. Fitness for purpose requirements and appropriate verification tests Hydrants |
EN 1074-6:2008 | Valves for water supply - Fitness for purpose requirements and appropriate verification tests - Part 6: Hydrants |
EN 1074-6:2008 | Valves for water supply - Fitness for purpose requirements and appropriate verification tests - Part 6: Hydrants |
EN 1503-1:2000 | Valves - Materials for bodies, bonnets and covers - Part 1: Steels specified in European Standards |
ISO 6708:1995 | Pipework components Definition and selection of DN (nominal size) |
EN 1074-1:2000 | Valves for water supply - Fitness for purpose requirements and appropriate verification tests - Part 1: General requirements |
EN 736-2:2016 | Valves - Terminology - Part 2: Definition of components of valves |
EN ISO 6708:1995 | Pipework components - Definition and selection of DN (nominal size) (ISO 6708:1995) |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
ISO 9001:2015 | Quality management systems — Requirements |
EN 1092-2:1997 | Flanges and their joints - Circular flanges for pipes, valves, fittings and accessories, PN designated - Part 2: Cast iron flanges |
EN 736-3:2008 | Valves - Terminology - Part 3: Definition of terms |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.