Fire resistance tests for service installations - Part 11: Fire protective systems for cable systems and associated components
01-14-2022
05-09-2018
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test equipment
5 Test conditions
6 Test specimen
7 Installation of test specimen
8 Conditioning
9 Application of instrumentation
10 Test procedure
11 Performance criteria
12 Test report
13 Field of direct application of test results
Annex A (informative) - Thermocouples inside the fire
protective systems
Annex B (informative) - Preheating
Annex C (informative) - Performance criteria for
communication/data cables
Bibliography
This European Standard describes the method to evaluate the performance of protective systems for electrical cable and busbar systems in order to maintain the circuit integrity under fire conditions to classify the protective system according to EN 13501 3 for the P classification. The test examines the behaviour of cable protection systems exposed to fire from outside. The tests specified in this standard are not aimed for assessing the performance of the fire protective system and the penetration seal for maintaining the requirements of the penetrated wall or ceiling (classification E / I).This method is very different to EN 50200 for the PH classification and also to IEC 60331 11, IEC 60331 21, IEC 60331 23, and IEC 60331 25, which are not designed for fire protective systems for electrical cable systems.This standard should be used in conjunction with EN 1363 1.The test results apply to fire protective systems for electrical cable systems rated for voltages up to 1 kV.The test procedure should also be used to determine the performance of protective systems for use with data and optical cables, however, verification procedures for such cables are still under development. Proposals are given in Annex C.The protective system may include ventilation devices, inspection hatches, fixed or removable lids etc.The tests specified in this standard are not aimed for assessing the performance of sprayed or painted coatings (e.g. intumescent or ablative coating, plastic film, epoxy resin) and similar protective layers (e.g. wrap, bandage) applied directly on the cables or bus bars as fire protective system. Also, cables and bus bars with intrinsic resistance to fire, and without fire protective systems around, are excluded (see CENELEC standard EN 50577).This test method is not applicable for cabinets for electrical accessory containing bus systems, relays or similar.Dieses Prüfverfahren gilt nicht für Schaltschränke für elektrische Zubehörteile wie Bussysteme, Relais u. ä.
Committee |
CEN/TC 127
|
DevelopmentNote |
Supersedes PREN 1366-11. (05/2018)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
ONORM EN 1366-11:2018 | Identical |
NS EN 1366-11:2018 | Identical |
DIN EN 1366-11:2018-07 | Identical |
NEN-EN 1366-11:2018 en | Identical |
PN-EN 1366-11:2018-06 | Identical |
I.S. EN 1366-11:2018 | Identical |
UNI EN 1366-11 : 2018 | Identical |
SS-EN 1366-11:2018 | Identical |
NF EN 1366-11:2018 | Identical |
UNE-EN 1366-11:2019 | Identical |
BS EN 1366-11:2018 | Identical |
SN EN 1366-11:2018 | Identical |
IEC 61537:2006 | Cable management - Cable tray systems and cable ladder systems |
EN 50582:2016 | Procedure to assess the circuit integrity of optical fibres in a cable under resistance to fire testing |
IEC 60331-11:1999+AMD1:2009 CSV | Tests for electric cables under fire conditions - Circuit integrity - Part 11: Apparatus - Fire alone at a flame temperature of at least 750 °C |
EN 50200:2015 | Method of test for resistance to fire of unprotected small cables for use in emergency circuits |
EN 50289-4-16:2016 | Communication cables - Specifications for test methods - Part 4-16: Environmental test methods - Circuit integrity under fire conditions |
ISO 13943:2017 | Fire safety — Vocabulary |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
HD 603 S1:1994/A3:2007 | DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
EN 50289-1-4:2001 | Communication cables - Specifications for test methods - Part 1-4: Electrical test methods - Insulation resistance |
IEC 60331-23:1999 | Tests for electric cables under fire conditions - Circuit integrity - Part 23: Procedures and requirements - Electric data cables |
EN 50288-7:2005 | Multi-element metallic cables used in analogue and digital communication and control - Part 7: Sectional specification for instrumentation and control cables |
EN 50288-1:2013 | Multi-element metallic cables used in analogue and digital communication and control - Part 1: Generic specification |
EN 50289-1-8:2017 | Communication cables - Specifications for test methods - Part 1-8: Electrical test methods - Attenuation |
IEC 60331-21:1999 | Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV |
EN 13501-3:2005+A1:2009 | Fire classification of construction products and building elements - Part 3: Classification using data from fire resistance tests on products and elements used in building service installations: fire resisting ducts and fire dampers |
EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
EN 1363-1:2012 | Fire resistance tests - Part 1: General Requirements |
EN 50289-1-11:2016 | Communication cables - Specifications for test methods - Part 1-11: Electrical test methods - Characteristic impedance, input impedance, return loss |
EN 1363-2:1999 | Fire resistance tests - Part 2: Alternative and additional procedures |
EN 50577:2015 | Electric cables - Fire resistance test for unprotected electric cables (P classification) |
EN 61537:2007 | Cable management - Cable tray systems and cable ladder systems |
EN 50289-1-5:2001 | Communication cables - Specifications for test methods - Part 1-5: Electrical test methods - Capacitance |
EN 50525-2-11:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation |
EN 60269-1:2007/A2:2014 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.