EN 13528-1:2002
Current
The latest, up-to-date edition.
Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 1: General requirements
09-25-2002
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Assessment regimes
5 Performance requirements
5.1 Unambiguity
5.2 Selectivity
5.3 Data Quality Objectives
5.4 Composite procedures
5.5 Environmental conditions
5.6 Description of measuring procedure
5.7 Dimension of result
5.8 Quality systems
6 Test methods
7 Test report
Annex A (informative) Assessment of ambient air quality
Bibliography
This part of the European Standard specifies general performance requirements for diffusive samplers used for the determination of the concentration of gases and vapours in ambient air. Such requirements apply to all diffusive samplers, irrespective of the physical nature of the rate controlling process and irrespective of the nature of the sorption process and the analytical determination. This standard applies to all stages of the measuring procedure, including deployment, transportation and storage of the sample where appropriate.
Committee |
CEN/TC 264
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
NF EN 13528-1 : 2003 | Identical |
UNE-EN 13528-1:2003 | Identical |
GOST R EN 13528-1 : 2010 | Identical |
PN EN 13528-1 : 2004 | Identical |
NEN EN 13528-1 : 2002 | Identical |
NS EN 13528-1 : 1ED 2002 | Identical |
SN EN 13528-1 : 2002 | Identical |
BS EN 13528-1:2002 | Identical |
UNI EN 13528-1 : 2003 | Identical |
I.S. EN 13528-1:2002 | Identical |
NBN EN 13528-1 : 2002 | Identical |
DIN EN 13528-1:2002-12 | Identical |
I.S. EN 16339:2013 | AMBIENT AIR - METHOD FOR THE DETERMINATION OF THE CONCENTRATION OF NITROGEN DIOXIDE BY DIFFUSIVE SAMPLING |
UNI EN ISO 9225 : 2012 | CORROSION OF METALS AND ALLOYS - CORROSIVITY OF ATMOSPHERES - MEASUREMENT OF ENVIRONMENTAL PARAMETERS AFFECTING CORROSIVITY OF ATMOSPHERES |
BS EN 13528-3:2003 | Ambient air quality. Diffusive samplers for the determination of concentrations of gases and vapours. Requirements and test methods Guide to selection, use and maintenance |
ISO 9225:2012 | Corrosion of metals and alloys — Corrosivity of atmospheres — Measurement of environmental parameters affecting corrosivity of atmospheres |
EN ISO 9225:2012 | Corrosion of metals and alloys - Corrosivity of atmospheres - Measurement of environmental parameters affecting corrosivity of atmospheres (ISO 9225:2012) |
EN 13528-3:2003 | Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 3: Guide to selection, use and maintenance |
I.S. EN ISO 9225:2012 | CORROSION OF METALS AND ALLOYS - CORROSIVITY OF ATMOSPHERES - MEASUREMENT OF ENVIRONMENTAL PARAMETERS AFFECTING CORROSIVITY OF ATMOSPHERES (ISO 9225:2012) |
DIN EN ISO 16017-2:2003-09 | INDOOR, AMBIENT AND WORKPLACE AIR - SAMPLING AND ANALYSIS OF VOLATILE ORGANIC COMPOUNDS BY SORBENT TUBE/THERMAL DESORPTION/CAPILLARY GAS CHROMATOGRAPHY - PART 2: DIFFUSIVE SAMPLING |
ISO 16000-15:2008 | Indoor air — Part 15: Sampling strategy for nitrogen dioxide (NO2) |
DIN EN ISO 16000-15:2009-04 | INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
VDI 3787 Blatt 10:2010-03 | Environmental meteorology - Human biometeorological requirements in the framework of recreation, prevention, therapy, and rehabilitation |
UNI EN ISO 16000-15 : 2008 | INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
DIN EN 16339:2013-11 | Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
BS EN ISO 16000-15:2008 | Indoor air Sampling strategy for nitrogen dioxide (NO2) |
BS EN ISO 9225:2012 | Corrosion of metals and alloys. Corrosivity of atmospheres. Measurement of environmental parameters affecting corrosivity of atmospheres |
06/30146336 DC : 0 | EN ISO 16000-15 - INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
UNE-EN 16339:2014 | Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
EN 14412:2004 | Indoor air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Guide for selection, use and maintenance |
EN ISO 16000-15:2008 | Indoor air - Part 15: Sampling strategy for nitrogen dioxide (NO2) (ISO 16000-15:2008) |
BS EN 16339:2013 | Ambient air. Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
I.S. EN ISO 16000-15:2008 | INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
BS EN ISO 16017-2:2003 | Indoor, ambient and workplace air. Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography Diffusive sampling |
BS EN 14412:2004 | Indoor air quality. Diffusive samplers the determination of concentrations of gases and vapours. Guide for selection, use and maintenance |
EN ISO 16017-2:2003 | Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 2: Diffusive sampling (ISO 16017-2:2003) |
EN 16339:2013 | Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling |
DIN EN ISO 9225:2012-05 | Corrosion of metals and alloys - Corrosivity of atmospheres - Measurement of environmental parameters affecting corrosivity of atmospheres (ISO 9225:2012) |
UNI EN 16339 : 2013 | AMBIENT AIR - METHOD FOR THE DETERMINATION OF THE CONCENTRATION OF NITROGEN DIOXIDE BY DIFFUSIVE SAMPLING |
ISO 16017-2:2003 | Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 2: Diffusive sampling |
DIN EN 13528-3:2004-04 | Ambient air quality - Diffuse samplers for the determination of concentrations of gases and vapours - Part 3: Guide to selection, use and maintenance |
DIN EN 14412:2004-12 | INDOOR AIR QUALITY - DIFFUSIVE SAMPLERS FOR THE DETERMINATION OF CONCENTRATIONS OF GASES AND VAPOURS - GUIDE FOR SELECTION, USE AND MAINTENANCE |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
EN 838:2010 | Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods |
EN 482:2012+A1:2015 | Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents |
ENV 13005 : DRAFT 1999 | GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT |
ISO 5725:1986 | Precision of test methods Determination of repeatability and reproducibility for a standard test method by inter-laboratory tests |
ISO 78-2:1999 | Chemistry Layouts for standards Part 2: Methods of chemical analysis |
ISO 3534-1:2006 | Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.