EN 132400 : 1994 AMD 4 2001
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
SECTIONAL SPECIFICATION: FIXED CAPACITORS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION AND CONNECTION TO THE SUPPLY MAINS (ASSESSMENT LEVEL D)
08-01-2005
01-12-2013
Foreword
1 GENERAL
1.1 Scope
1.2 Object
1.3 Related documents
1.4 Information to be given in a detail specification
1.5 Terminology
1.6 Marking
2 PREFERRED RATINGS AND CHARACTERISTICS
2.1 Preferred climatic categories
2.2 Preferred values of ratings
3 ASSESSMENT PROCEDURES
3.1 Primary stage of manufacture
3.2 Structurally similar components
3.3 Certified test records
3.4 Approval testing
3.5 Conformance inspection
4 TEST AND MEASUREMENT PROCEDURES
4.1 Visual examination and check of dimensions
4.2 Electrical tests
4.3 Robustness of terminations
4.4 Resistance to soldering heat
4.5 Solderability
4.6 Rapid change of temperature
4.7 Vibration
4.8 Bump
4.9 Shock
4.10 Container sealing
4.11 Climatic sequence
4.12 Damp heat, steady state
4.13 Impulse voltage
4.14 Endurance
4.15 Charge and discharge
4.16 Radio frequency characteristics
4.17 Passive flammability
4.18 Active flammability
4.19 Component solvent resistance
4.20 Solvent resistance of the marking
Annex A1 Test schedule for safety tests only
Annex A2 Test schedule for safety tests and qualification
approval tests - Assessment Level D
Annex B Circuit for the impulse voltage test
Annex C Circuit for the endurance test
Annex D Circuit for the charge and discharge test
Annex E Pulse test circuits
Annex F Declaration of design
Defines capacitors for connection to an a.c. mains or other supply with a nominal voltage not exceeding 1000 V a.c. (r.m.s) or 1000 V d.c. and with a maximum nominal frequency of 100 Hz.
Committee |
TC 40XA
|
DevelopmentNote |
Supersedes CECC 32 400. (02/2002)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN 132400:1994 | Identical |
NF EN 132400 : AMD 4 2000 PR | Identical |
SN EN 132400 : AMD 4 2001 | Identical |
NEN EN 132400 : 97 AMD 4 2001 | Identical |
BS EN 132400:1995 | Similar to |
CEI EN 132400 : 1ED 1996 | Identical |
DIN EN 132400 : 2002 | Identical |
I.S. EN 132400:1994 | Identical |
IEC 60384-14:2013+AMD1:2016 CSV | Similar to |
VDE 0565-1-1 : 2014 AMD 1 2017 | Identical |
03/314480 DC : DRAFT SEP 2003 | EN 50065-4-7 - SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ AND FROM 1,6 MHZ TO 30 MHZ - PART 4-7: SAFETY OF PORTABLE FILTERS |
EN 132421:1997 | Blank Detail Specification: Fixed capacitors for electromagnetic interference suppression - Capacitors for which safety tests are required (Safety tests only) |
EN 133200:1999 | Sectional Specification: Passive filter units for electromagnetic interference suppression (Filters for which safety tests are required) |
EN 50065-4-2 : 2001 AMD 2 2005 | SIGNALLING ON LOW VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 4-2: LOW VOLTAGE DECOUPLING FILTERS - SAFETY REQUIREMENTS |
BS EN 50065-4-7:2005 | Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz and 1,6 MHz to 30 MHz Portable low voltage decoupling filters. Safety requirements |
I.S. EN 132401:1994 | FIXED CAPACITORS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION AND CONNECTION TO THE SUPPLY MAINS (ASSESSMENT LEVEL D) (BLANK DETAIL SPECIFICATION) |
EN 132401:1994 | Blank Detail Specification: Fixed capacitors for electromagnetic interference suppression and connection to the supply mains (Assessment level D) |
BS EN 133200:1999 | Harmonized system of quality assessment for electronic components. Sectional specification:passive filter units for electromagnetic interference suppression (filters for which safety tests are required) |
BS EN 132421:1997 | Harmonized system of quality assessment for electronic components. Blank detail specification: fixed capacitors for electromagnetic interference suppression. Capacitors for which safety tests are required (safety tests only) |
98/230449 DC : DRAFT FEB 1998 | PREN 133200 - SECTIONAL SPECIFICATION - PASSIVE FILTER UNITS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION (FILTERS FOR WHICH SAFETY TESTS ARE REQUIRED) |
CEI EN 50065-4-7 : 2007 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ AND FROM 1,6 MHZ TO 30 MHZ - PART 4-7: PORTABLE LOW VOLTAGE DECOUPLING FILTERS - SAFETY REQUIREMENTS |
I.S. EN 133200:1995 | PASSIVE FILTER UNITS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION (FILTERS FOR WHICH SAFETY TESTS ARE REQUIRED) (SECTIONAL SPECIFICATION) |
I.S. EN 50065-4-7:2005 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ AND 1,6 MHZ TO 30 MHZ - PART 4-7: PORTABLE LOW VOLTAGE DECOUPLING FILTERS - SAFETY REQUIREMENTS |
NF EN 50065 4-7 : 2005 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ AND FROM 1,6 MHZ TO 30 MHZ - PART 4-7: PORTABLE LOW VOLTAGE DECOUPLING FILTERS - SAFETY REQUIREMENTS |
BS EN 50065-4-2:2002 | Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz and 1,6 MHz to 30 MHz. Low voltage decoupling filters Safety requirements |
EN 50065-4-7 : 2005 COR 2006 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ AND 1,6 MHZ TO 30 MHZ - PART 4-7: PORTABLE LOW VOLTAGE DECOUPLING FILTERS - SAFETY REQUIREMENTS |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
ISO 3:1973 | Preferred numbers Series of preferred numbers |
EN 130000 : 93 AMD 10 | FIXED CAPACITORS |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 60940:2015 | Guidance information on the application of capacitors, resistors, inductors and complete filter units for electromagnetic interference suppression |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
IEC 60062:2016 | Marking codes for resistors and capacitors |
IEC 60063:2015 | Preferred number series for resistors and capacitors |
CISPR 17:2011 | Methods of measurement of the suppression characteristics of passive EMC filtering devices |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.