EN 13238:2010
Current
The latest, up-to-date edition.
Reaction to fire tests for building products - Conditioning procedures and general rules for selection of substrates
02-10-2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Conditioning procedures
5 General rules for selection of substrates
Bibliography
This European Standard describes the conditioning procedures for test specimens which will be tested according to the European standards for reaction to fire.The rules for the selection of substrates for construction products when carrying out reaction to fire tests are also detailed in this European Standard. This European Standard does not contain requirements for-the pre-drying of test specimens for the non-combustibility test according EN ISO 1182;-methods of cleaning (e.g. washing) and other methods for the assessment of durability aspects, which are dealt with in the relevant product standards.
Committee |
CEN/TC 127
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
PN EN 13238 : 2011 | Identical |
NBN EN 13238 : 2010 | Identical |
UNI EN 13238 : 2010 | Identical |
NEN EN 13238 : 2010 | Identical |
I.S. EN 13238:2010 | Identical |
SN EN 13238 : 2010 | Identical |
BS EN 13238:2010 | Identical |
NS EN 13238 : 2010 | Identical |
NEN EN 13238 : 2018 Ontw | Identical |
SS-EN 13238:2010 | Identical |
NF EN 13238 : 2012 | Identical |
UNE-EN 13238:2011 | Identical |
DIN EN 13238:2010-06 | Identical |
PREN 15497 : DRAFT 2011 | STRUCTURAL FINGER JOINTED SOLID TIMBER - PERFORMANCE REQUIREMENTS AND MINIMUM PRODUCTION REQUIREMENTS |
15/30315069 DC : DRAFT MAY 2015 | BS EN 14313 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
PD CEN/TS 15912:2012 | Durability of reaction to fire performance. Classes of fire-retardant treated wood-based product in interior and exterior end use applications |
BS EN 12004-1:2017 | Adhesives for ceramic tiles Requirements, assessment and verification of constancy of performance, classification and marking |
CEN/TR 14819-2:2005 | Safety recommendations for cableway installations designed to carry persons - Prevention and fight against fire - Part 2: Other funicular railways and other installations |
11/30238641 DC : 0 | BS EN 491 - CONCRETE ROOFING TILES AND FITTINGS FOR ROOF COVERING AND WALL CLADDING - TEST METHODS |
PREN 14313 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
CEI UNI EN 45545-2 : 2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAUVIOR OF MATERIALS AND COMPONENTS |
PREN 13859-2 : DRAFT 2013 | FLEXIBLE SHEETS FOR WATERPROOFING - DEFINITIONS AND CHARACTERISTICS OF UNDERLAYS - PART 2: UNDERLAYS FOR WALLS |
UNE-EN 14306:2017 | Thermal insulation products for building equipment and industrial installations - Factory made calcium silicate (CS) products - Specification |
15/30315078 DC : DRAFT MAY 2015 | BS EN 14307 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
DIN EN 15497 E : 2014 | STRUCTURAL FINGER JOINTED SOLID TIMBER - PERFORMANCE REQUIREMENTS AND MINIMUM PRODUCTION REQUIREMENTS |
07/30167661 DC : DRAFT AUG 2007 | BS EN 15715 - THERMAL INSULATION PRODUCTS - INSTRUCTIONS FOR MOUNTING AND FIXING FOR REACTION TO FIRE TESTING - FACTORY MADE PRODUCTS |
DIN EN ISO 9239-1:2010-11 | Reaction to fire tests for floorings - Part 1: Determination of the burning behaviour using a radiant heat source (ISO 9239-1:2010) |
05/30136503 DC : 0 | PREN 14309 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
I.S. EN ISO 1716:2010 | REACTION TO FIRE TESTS FOR PRODUCTS - DETERMINATION OF THE GROSS HEAT OF COMBUSTION (CALORIFIC VALUE) |
11/30253102 DC : 0 | BS EN 16351 - TIMBER STRUCTURES - CROSS LAMINATED TIMBER - REQUIREMENTS |
PREN 14309 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
09/30171916 DC : DRAFT JAN 2009 | BS EN ISO 9239-1 - REACTION TO FIRE TESTS FOR FLOORINGS - PART 1: DETERMINATION OF THE BURNING BEHAVIOUR USING A RADIANT HEAT SOURCE |
05/30134359 DC : DRAFT MAY 2005 | EN 15101-1 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL CELLULOSE PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
DIN EN 14303:2016-08 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
PREN 14904-1 : DRAFT 2017 | SURFACES FOR SPORTS AREAS - MULTI-SPORTS FLOOR SYSTEMS FOR INDOOR USE - PART 1: ESSENTIAL CHARACTERISTICS |
I.S. EN 14320-1:2013 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
05/30136556 DC : 0 | PREN 14313 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATION - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
DIN EN 14306:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CALCIUM SILICATE (CS) PRODUCTS - SPECIFICATION |
DIN EN 14313:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
BS EN 14307:2015 | Thermal insulation products for building equipment and industrial installations. Factory made extruded polystyrene foam (XPS) products. Specification |
PREN 14081-1 : DRAFT 2013 | TIMBER STRUCTURES - STRENGTH GRADED STRUCTURAL TIMBER WITH RECTANGULAR CROSS SECTION - PART 1: GENERAL REQUIREMENTS |
BS EN 15651-3:2017 | Sealants for non-structural use in joints in buildings and pedestrian walkways Sealants for sanitary joints |
DIN EN ISO 1716:2010-11 | REACTION TO FIRE TESTS FOR PRODUCTS - DETERMINATION OF THE GROSS HEAT OF COMBUSTION (CALORIFIC VALUE) |
S.R. CEN/TS 15912:2012 | DURABILITY OF REACTION TO FIRE PERFORMANCE - CLASSES OF FIRE-RETARDANT TREATED WOOD-BASED PRODUCT IN INTERIOR AND EXTERIOR END USE APPLICATIONS |
ISO 10840:2008 | Plastics — Guidance for the use of standard fire tests |
DIN EN 14304:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION |
CEN/TR 14819-1:2004 | Safety recommendations for cableway installations designed to carry persons - Prevention and fight against fire - Part 1: Funicular railways in tunnels |
I.S. EN 14304:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION |
S.R. CEN/TS 1187:2012 | TEST METHODS FOR EXTERNAL FIRE EXPOSURE TO ROOFS |
I.S. EN 15101-1:2013 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
BS EN 45545-2 : 2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
I.S. EN 13501-1:2007 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 1: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS |
I.S. EN 15651-4:2017 | SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 4: SEALANTS FOR PEDESTRIAN WALKWAYS |
ISO 9705-1:2016 | Reaction to fire tests Room corner test for wall and ceiling lining products Part 1: Test method for a small room configuration |
UNI EN ISO 25762 : 2012 | PLASTICS - GUIDANCE ON THE ASSESSMENT OF THE FIRE CHARACTERISTICS AND FIRE PERFORMANCE OF FIBRE-REINFORCED POLYMER COMPOSITES |
EN 15102:2007+A1:2011 | Decorative wall coverings - Roll and panel form |
UNI EN 15101-1 : 2013 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
UNE-EN 15651-4:2017 | Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 4: Sealants for pedestrian walkways |
UNI EN ISO 1716 : 2010 | REACTION TO FIRE TESTS FOR PRODUCTS - DETERMINATION OF THE GROSS HEAT OF COMBUSTION (CALORIFIC VALUE) |
UNE-EN 14318-1:2013 | Thermal insulating products for buildings - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam dispensed system before installation |
16/30325907 DC : 0 | BS EN 15102 - DECORATIVE WALLCOVERINGS - ROLL FORM |
XP CEN/TS 45545-2 : 2009 XP | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
EN 15101-1:2013 | Thermal insulation products for buildings - In-situ formed loose fill cellulose (LFCI) products - Part 1: Specification for the products before installation |
I.S. EN 14915:2013 | SOLID WOOD PANELLING AND CLADDING - CHARACTERISTICS, EVALUATION OF CONFORMITY AND MARKING |
EN 14915:2013+A1:2017 | Solid wood panelling and cladding - Characteristics, requirements and marking |
DIN EN 13500:2003-12 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS (ETICS) BASED ON MINERAL WOOL - SPECIFICATION |
DIN EN 13499:2003-12 | Thermal insulation products for buildings - External thermal insulation composite systems (ETICS) based on expanded polystyrene - Specification; German version EN 13499:2003 |
DIN EN 13859-1:2014-07 | FLEXIBLE SHEETS FOR WATERPROOFING - DEFINITIONS AND CHARACTERISTICS OF UNDERLAYS - PART 1: UNDERLAYS FOR DISCONTINUOUS ROOFING |
13/30280057 DC : 0 | BS EN 13782 - TEMPORARY STRUCTURE - TENTS - SAFETY |
BS EN 491:2011 | Concrete roofing tiles and fittings for roof covering and wall cladding. Test methods |
BS EN 13499:2003 | Thermal insulation products for buildings. External thermal insulation composite systems (ETICS) based on expanded polystyrene. Specification |
ISO 9239-1:2010 | Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source |
UNE-EN 491:2012 | Concrete roofing tiles and fittings for roof covering and wall cladding - Test methods |
BS EN 14390:2007 | Fire test. Large-scale room reference test for surface products |
UNE-CEN/TS 1187:2013 | Test methods for external fire exposure to roofs |
I.S. EN ISO 9239-1:2010 | REACTION TO FIRE TESTS FOR FLOORINGS - PART 1: DETERMINATION OF THE BURNING BEHAVIOUR USING A RADIANT HEAT SOURCE |
EN 13500:2003 | Thermal insulation products for buildings - External thermal insulation composite systems (ETICS) based on mineral wool - Specification |
CEN/TS 16354:2013 | Laminate floor coverings - Underlays - Specification, requirements and test methods |
DIN EN 14041:2008-05 | RESILIENT, TEXTILE AND LAMINATE FLOOR COVERINGS - ESSENTIAL CHARACTERISTICS |
DIN EN 14904:2006-06 | Surfaces for sports areas - Indoor surfaces for multi-sports use - Specification |
DIN EN 13830:2015-07 | CURTAIN WALLING - PRODUCT STANDARD |
EN 13499:2003 | Thermal insulation products for buildings - External thermal insulation composite systems (ETICS) based on expanded polystyrene - Specification |
EN 12004:2007+A1:2012 | Adhesives for tiles - Requirements, evaluation of conformity, classification and designation |
EN 16755:2017 | Durability of reaction to fire performance - Classes of fire-retardant treated wood products in interior and exterior end use applications |
DIN EN 15725:2012-05 | Extended application reports on the fire performance of construction products and building elements (includes Corrigendum AC:2012) |
EN 14250:2010 | Timber structures - Product requirements for prefabricated structural members assembled with punched metal plate fasteners |
DIN EN 12004-1:2017-05 | ADHESIVES FOR CERAMIC TILES - PART 1: REQUIREMENTS, ASSESSMENT AND VERIFICATION OF CONSTANCY OF PERFORMANCE, CLASSIFICATION AND MARKING |
PREN 14188-2 : DRAFT 2014 | JOINT FILLERS AND SEALANTS - PART 2: SPECIFICATIONS FOR COLD APPLIED SEALANTS |
I.S. EN 15497:2014 | STRUCTURAL FINGER JOINTED SOLID TIMBER - PERFORMANCE REQUIREMENTS AND MINIMUM PRODUCTION REQUIREMENTS |
DIN EN ISO 1182:2010-10 | REACTION TO FIRE TESTS FOR PRODUCTS - NON-COMBUSTIBILITY TEST |
15/30315087 DC : DRAFT MAY 2015 | BS EN 14314 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
07/30161873 DC : 0 | EN 15651-4 - SEALANTS FOR JOINTS IN BUILDING CONSTRUCTION - DEFINITIONS, REQUIREMENTS AND EVALUATION OF CONFORMITY - PART 4: SEALANTS FOR PEDESTRIAN WALKWAYS |
PREN 14915 : DRAFT 2013 | SOLID WOOD PANELLING AND CLADDING - CHARACTERISTICS, EVALUATION OF CONFORMITY AND MARKING |
I.S. EN 15651-2:2017 | SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 2: SEALANTS FOR GLAZING |
I.S. EN 16025-1:2013 | THERMAL AND/OR SOUND INSULATING PRODUCTS IN BUILDING CONSTRUCTION - BOUND EPS BALLASTINGS - PART 1: REQUIREMENTS FOR FACTORY PREMIXED EPS DRY PLASTER |
DD CEN/TS 1187:2012 | Test methods for external fire exposure to roofs |
DIN EN 14320-1:2013-04 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
DIN EN 16623:2015-04 | PAINTS AND VARNISHES - REACTIVE COATINGS FOR FIRE PROTECTION OF METALLIC SUBSTRATES - DEFINITIONS, REQUIREMENTS, CHARACTERISTICS AND MARKING |
04/19990095 DC : 0 | BS EN 45545-2 - RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
DIN EN ISO 25762:2012-04 | Plastics - Guidance on the assessment of the fire characteristics and fire performance of fibre-reinforced polymer composites (ISO 25762:2009) |
15/30315081 DC : DRAFT MAY 2015 | BS EN 14308 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - SPECIFICATION |
09/30200088 DC : 0 | BS EN 14879-6 - ORGANIC COATING SYSTEMS AND LININGS FOR PROTECTION OF INDUSTRIAL APPARATUS AND PLANTS AGAINST CORROSION CAUSED BY AGGRESSIVE MEDIA - PART 6: COMBINED LININGS WITH TILE AND BRICK LAYERS |
13/30273039 DC : 0 | BS EN 13859-2 - FLEXIBLE SHEETS FOR WATERPROOFING - DEFINITIONS AND CHARACTERISTICS OF UNDERLAYS - PART 2: UNDERLAYS FOR WALLS |
BS EN 16623:2015 | Paints and varnishes. Reactive coatings for fire protection of metallic substrates. Definitions, requirements, characteristics and marking |
DIN EN 15651-1:2016-10 (Draft) | SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 1: SEALANTS FOR FACADE ELEMENTS |
BS EN 14320-1:2013 | Thermal insulating products for building equipment and industrial installations. In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products Specification for the rigid foam spray system before installation |
DIN EN 15497:2014-07 | STRUCTURAL FINGER JOINTED SOLID TIMBER - PERFORMANCE REQUIREMENTS AND MINIMUM PRODUCTION REQUIREMENTS |
DIN EN 14879-6:2010-04 | Organic coating systems and linings for protection of industrial apparatus and plants against corrosion caused by aggressive media - Part 6: Combined linings with tile and brick layers |
BS ISO 10840:2008 | Plastics. Guidance for the use of standard fire tests |
I.S. EN 14319-1:2013 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
16/30339855 DC : 0 | BS EN 14041 - RESILIENT, TEXTILE AND LAMINATE FLOOR COVERINGS - ESSENTIAL CHARACTERISTICS |
DIN EN 16025-1:2013-07 | THERMAL AND/OR SOUND INSULATING PRODUCTS IN BUILDING CONSTRUCTION - BOUND EPS BALLASTINGS - PART 1: REQUIREMENTS FOR FACTORY PREMIXED EPS DRY PLASTER |
05/30136516 DC : 0 | PREN 14308 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - SPECIFICATION |
BS EN 14879-6:2009 | Organic coating systems and linings for protection of industrial apparatus and plants against corrosion caused by aggressive media Combined linings with tile and brick layers |
BS EN 16025-1:2013 | Thermal and/or sound insulating products in building construction. Bound EPS ballastings Requirements for factory premixed EPS dry plaster |
BS EN 16351:2015 | Timber structures. Cross laminated timber. Requirements |
DIN EN 15651-4:2016-10 (Draft) | SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 4: SEALANTS FOR PEDESTRIAN WALKWAYS |
BS EN 14303 : 2009 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
04/19993011 DC : DRAFT JUN 2004 | BS EN 14904 - SURFACES FOR SPORTS AREAS - SPECIFICATION FOR INDOOR SURFACES FOR MULTI-SPORTS USE |
PREN 13859-1 : DRAFT 2013 | FLEXIBLE SHEETS FOR WATERPROOFING - DEFINITIONS AND CHARACTERISTICS OF UNDERLAYS - PART 1: UNDERLAYS FOR DISCONTINUOUS ROOFING |
08/30169882 DC : DRAFT JAN 2008 | BS EN 15725 - EXTENDED APPLICATION REPORTS ON THE FIRE PERFORMANCE OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS |
I.S. EN 14305:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
PREN 14314 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
05/30136550 DC : 0 | PREN 14314 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
PREN 490 : DRAFT 2011 | CONCRETE ROOFING TILES AND FITTINGS FOR ROOF COVERING AND WALL CLADDING - PRODUCT SPECIFICATIONS |
PREN 14374 : DRAFT 2016 | TIMBER STRUCTURES - LAMINATED VENEER LUMBER (LVL) - REQUIREMENTS |
PREN 14304 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION |
UNE-EN 16623:2015 | Paints and varnishes - Reactive coatings for fire protection of metallic substrates - Definitions, requirements, characteristics and marking |
PREN 14783 : DRAFT 2012 | FULLY SUPPORTED METAL SHEET AND STRIP FOR ROOFING, EXTERNAL CLADDING AND INTERNAL LINING - PRODUCT SPECIFICATION AND REQUIREMENTS |
NF EN 15715 : 2010 | THERMAL INSULATION PRODUCTS - INSTRUCTIONS FOR MOUNTING AND FIXING FOR REACTION TO FIRE TESTING - FACTORY MADE PRODUCTS |
I.S. EN 14306:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CALCIUM SILICATE (CS) PRODUCTS - SPECIFICATION |
UNI EN 15497 : 2014 | STRUCTURAL FINGER JOINTED SOLID TIMBER - PERFORMANCE REQUIREMENTS AND MINIMUM PRODUCTION REQUIREMENTS |
I.S. EN 12004-1:2017 | ADHESIVES FOR CERAMIC TILES - PART 1: REQUIREMENTS, ASSESSMENT AND VERIFICATION OF CONSTANCY OF PERFORMANCE, CLASSIFICATION AND MARKING |
UNE-EN 14309:2017 | Thermal insulation products for building equipment and industrial installations - Factory made products of expanded polystyrene (EPS) - Specification |
DIN EN 14308:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - SPECIFICATION |
DIN EN 14309:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
I.S. EN 14081-1:2016 | TIMBER STRUCTURES - STRENGTH GRADED STRUCTURAL TIMBER WITH RECTANGULAR CROSS SECTION - PART 1: GENERAL REQUIREMENTS |
PREN 14305 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
BS EN 15814 : 2011 | POLYMER MODIFIED BITUMINOUS THICK COATINGS FOR WATERPROOFING - DEFINITIONS AND REQUIREMENTS |
I.S. EN 45545-2:2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
BS EN 14304 : 2009 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION |
UNE-EN 15725:2011 | Extended application reports on the fire performance of construction products and building elements |
I.S. EN 14303:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
PREN 16354 : DRAFT 2016 | LAMINATE FLOOR COVERINGS - UNDERLAYS - SPECIFICATION, REQUIREMENTS AND TEST METHODS |
PREN 14306 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CALCIUM SILICATE (CS) PRODUCTS - SPECIFICATION |
I.S. EN 15814:2011 | POLYMER MODIFIED BITUMINOUS THICK COATINGS FOR WATERPROOFING - DEFINITIONS AND REQUIREMENTS |
DIN EN 15101-1:2013-12 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
I.S. CEN/TS 15117:2005 | GUIDANCE ON DIRECT AND EXTENDED APPLICATION |
16/30333219 DC : 0 | BS EN 16354 - LAMINATE FLOOR COVERINGS - UNDERLAYS - SPECIFICATION, REQUIREMENTS AND TEST METHODS |
UNI EN 15715 : 2009 | THERMAL INSULATION PRODUCTS - INSTRUCTIONS FOR MOUNTING AND FIXING FOR REACTION TO FIRE TESTING - FACTORY MADE PRODUCTS |
I.S. CEN TR 14819-1:2004 | SAFETY RECOMMENDATIONS FOR CABLEWAY INSTALLATIONS DESIGNED TO CARRY PERSONS - PREVENTION AND FIGHT AGAINST FIRE - PART 1: FUNICULAR RAILWAYS IN TUNNELS |
S.R. CEN/TS 45545-2:2009 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
DIN EN 14716:2005-03 | Stretched ceilings - Requirements and tests methods; German version EN 14716:2004 |
DIN EN 14250:2010-05 | Timber structures - Product requirements for prefabricated structural members assembled with punched metal plate fasteners |
DIN EN 14390:2007-04 | Fire test - Large-scale room reference test for surface products |
DIN EN 12004:2014-02 | ADHESIVES FOR TILES - REQUIREMENTS, EVALUATION OF CONFORMITY, CLASSIFICATION AND DESIGNATION |
UNE-EN 13830:2016 | Curtain walling - Product standard |
BS EN 14716:2004 | Stretched ceilings. Requirements and test methods |
BS EN 13859-2:2014 | Flexible sheets for waterproofing. Definitions and characteristics of underlays Underlays for walls |
EN 45545-2:2013+A1:2015 | Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behaviour of materials and components |
I.S. EN 13830:2015 | CURTAIN WALLING - PRODUCT STANDARD |
I.S. EN 13859-1:2014 | FLEXIBLE SHEETS FOR WATERPROOFING - DEFINITIONS AND CHARACTERISTICS OF UNDERLAYS - PART 1: UNDERLAYS FOR DISCONTINUOUS ROOFING |
I.S. EN 14351-1:2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND/OR SMOKE LEAKAGE CHARACTERISTICS |
I.S. EN 14783:2013 | FULLY SUPPORTED METAL SHEET AND STRIP FOR ROOFING, EXTERNAL CLADDING AND INTERNAL LINING - PRODUCT SPECIFICATION AND REQUIREMENTS |
I.S. EN 490:2011 | CONCRETE ROOFING TILES AND FITTINGS FOR ROOF COVERING AND WALL CLADDING - PRODUCT SPECIFICATIONS |
I.S. EN 13859-2:2014 | FLEXIBLE SHEETS FOR WATERPROOFING - DEFINITIONS AND CHARACTERISTICS OF UNDERLAYS - PART 2: UNDERLAYS FOR WALLS |
I.S. EN 14250:2010 | TIMBER STRUCTURES - PRODUCT REQUIREMENTS FOR PREFABRICATED STRUCTURAL MEMBERS ASSEMBLED WITH PUNCHED METAL PLATE FASTENERS |
I.S. EN 491:2011 | CONCRETE ROOFING TILES AND FITTINGS FOR ROOF COVERING AND WALL CLADDING - TEST METHODS |
EN 16351:2015 | Timber structures - Cross laminated timber - Requirements |
09/30203195 DC : 0 | BS EN 15497 - FINGER JOINTED STRUCTURAL TIMBER - PERFORMANCE REQUIREMENTS AND MINIMUM PRODUCTION REQUIREMENTS |
UNI CEI EN 45545-2 : 2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAUVIOR OF MATERIALS AND COMPONENTS |
15/30315075 DC : DRAFT MAY 2015 | BS EN 14305 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
I.S. EN 15102:2007 | DECORATIVE WALL COVERINGS - ROLL AND PANEL FORM |
BS EN 16733:2016 | Reaction to fire tests for building products. Determination of a building product\'s propensity to undergo continuous smouldering |
UNE-EN 15651-1:2017 | Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 1: Sealants for facade elements |
UNE-EN 13501-1:2007 | Fire classification of construction products and building elements - Part 1: Classification using data from reaction to fire tests |
10/30216687 DC : 0 | BS EN 45545-2 - RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
PD CEN/TR 14819-2:2005 | Safety recommendations for cableway installations designed to carry persons. Prevention and fight against fire Other funicular railways and other installations |
BS EN 15715:2009 | Thermal insulation products. Instructions for mounting and fixing for reaction to fire testing. Factory made products |
BS ISO 25762 : 2009 | PLASTICS - GUIDANCE ON THE ASSESSMENT OF THE FIRE CHARACTERISTICS AND FIRE PERFORMANCE OF FIBRE-REINFORCED POLYMER COMPOSITES |
DIN EN 15651-2:2016-10 (Draft) | SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 2: SEALANTS FOR GLAZING |
BS EN 15497:2014 | Structural finger jointed solid timber. Performance requirements and minimum production requirements |
12/30264370 DC : 0 | BS EN 14783 - FULLY SUPPORTED METAL SHEET AND STRIP FOR ROOFING, EXTERNAL CLADDING AND INTERNAL LINING - PRODUCT SPECIFICATION AND REQUIREMENTS |
14/30287830 DC : 0 | BS EN 16733 - BUILDING PRODUCTS - DETERMINATION OF A BUILDING PRODUCTS PROPENSITY TO UNDERGO CONTINUOUS SMOULDERING |
11/30244187 DC : 0 | BS EN 14041 - RESILIENT, TEXTILE AND LAMINATE FLOOR COVERINGS - ESSENTIAL CHARACTERISTICS |
DIN EN 15651-3:2016-10 (Draft) | SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 3: SEALANTS FOR SANITARY JOINTS |
13/30258117 DC : 0 | BS EN 15101-1 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
BS EN 14315-1:2013 | Thermal insulating products for buildings. In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products Specification for the rigid foam spray system before installation |
UNI CEN/TS 15912 : 2012 | DURABILITY OF REACTION TO FIRE PERFORMANCE - CLASSES OF FIRE-RETARDANT TREATED WOOD-BASED PRODUCT IN INTERIOR AND EXTERIOR END USE APPLICATIONS |
DD CEN/TS 15117:2005 | Guidance on direct and extended application |
DIN EN 15498:2008-08 | PRECAST CONCRETE PRODUCTS - WOOD-CHIP CONCRETE SHUTTERING BLOCKS - PRODUCT PROPERTIES AND PERFORMANCE |
16/30304294 DC : 0 | BS EN 16989 - RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - FIRE BEHAVIOUR TEST FOR A COMPLETE SEAT |
07/30163072 DC : 0 | BS EN 15651-1 - SEALANTS FOR JOINTS IN BUILDING CONSTRUCTION - DEFINITIONS, REQUIREMENTS AND EVALUATION OF CONFORMITY - PART 1: SEALANTS FOR FACADE |
UNE-EN 16733:2016 | Reaction to fire tests for building products - Determination of a building product's propensity to undergo continuous smouldering |
12/30261882 DC : 0 | BS EN 14081-1 - TIMBER STRUCTURES - STRENGTH GRADED STRUCTURAL TIMBER WITH RECTANGULAR CROSS-SECTION - PART 1: GENERAL REQUIREMENTS |
DIN EN 16733:2016-07 | REACTION TO FIRE TESTS FOR BUILDING PRODUCTS - DETERMINATION OF A BUILDING PRODUCT'S PROPENSITY TO UNDERGO CONTINUOUS SMOULDERING |
13/30273036 DC : 0 | BS EN 13859-1 - FLEXIBLE SHEETS FOR WATERPROOFING - DEFINITIONS AND CHARACTERISTICS OF UNDERLAYS - PART 1: UNDERLAYS FOR DISCONTINUOUS ROOFING |
BS EN 15725:2010 | Extended application reports on the fire performance of construction products and building elements |
09/30171920 DC : DRAFT JAN 2009 | BS EN ISO 11925-2 - REACTION TO FIRE TESTS - IGNITABILITY OF BUILDING PRODUCTS SUBJECTED TO DIRECT IMPINGEMENT OF FLAME - PART 2: SINGLE-FLAME SOURCE TEST |
UNI EN 14320-1 : 2013 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
DIN EN 15715:2010-04 | Thermal insulation products - Instructions for mounting and fixing for reaction to fire testing - Factory made products |
UNE-EN 14305:2017 | Thermal insulation products for building equipment and industrial installations - Factory made cellular glass (CG) products - Specification |
I.S. EN 14309:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
15/30315072 DC : DRAFT MAY 2015 | BS EN 14306 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CALCIUM SILICATE (CS) PRODUCTS - SPECIFICATION |
09/30207865 DC : 0 | BS EN 13859-1 - FLEXIBLE SHEETS FOR WATERPROOFING - DEFINITIONS AND CHARACTERISTICS OF UNDERLAYS - PART 1: UNDERLAYS FOR DISCONTINUOUS ROOFING |
11/30236369 DC : 0 | BS EN 14080 - TIMBER STRUCTURES - GLUED LAMINATED TIMBER AND GLUED SOLID TIMBER |
DIN EN 14315-1:2013-04 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
09/30194024 DC : DRAFT FEB 2009 | BS EN 15912 - DURABILITY OF REACTION TO FIRE PERFORMANCES - CLASSES OF FIRE RETARDANT TREATED WOOD-BASED PRODUCT IN INTERIOR AND EXTERIOR END USE APPLICATIONS |
BS EN 14314:2015 | Thermal insulation products for building equipment and industrial installations. Factory made phenolic foam (PF) products. Specification |
UNI CEN/TS 16354 : 2014 | LAMINATE FLOOR COVERINGS - UNDERLAYS - SPECIFICATION, REQUIREMENTS AND TEST METHODS |
BS EN 15498:2008 | Precast concrete products. Wood-chip concrete shuttering blocks. Product properties and performance |
UNE-EN 14320-1:2013 | Thermal insulating products for building equipment and industrial installations - In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products - Part 1: Specification for the rigid foam spray system before installation |
DIN EN 14307:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
UNE-EN 14313:2017 | Thermal insulation products for building equipment and industrial installations - Factory made polyethylene foam (PEF) products - Specification |
PREN 14308 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - SPECIFICATION |
ISO 14697:2007 | Reaction-to-fire tests — Guidance on the choice of substrates for building and transport products |
I.S. EN 15715:2009 | THERMAL INSULATION PRODUCTS - INSTRUCTIONS FOR MOUNTING AND FIXING FOR REACTION TO FIRE TESTING - FACTORY MADE PRODUCTS |
PREN 16755 : DRAFT 2014 | DURABILITY OF REACTION TO FIRE PERFORMANCE - CLASSES OF FIRERETARDANT TREATED WOOD PRODUCTS IN INTERIOR AND EXTERIOR END USE APPLICATIONS |
DIN EN 14314:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
BS EN 15651-2:2017 | Sealants for non-structural use in joints in buildings and pedestrian walkways Sealants for glazing |
DIN EN 14305:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
15/30329856 DC : 0 | BS EN 14904 - SURFACES FOR SPORTS AREAS - INDOOR SURFACES FOR MULTI-SPORTS USE - SPECIFICATION |
BS EN 14309:2015 | Thermal insulation products for building equipment and industrial installations. Factory made products of expanded polystyrene (EPS). Specification |
I.S. EN 14041:2018 | RESILIENT, TEXTILE, LAMINATE AND MODULAR MULTILAYER FLOOR COVERINGS - ESSENTIAL CHARACTERISTICS |
BS EN 16724:2016 | Thermal insulation products for building applications. Instructions for mounting and fixing for determination of the reaction to fire testing of external thermal Insulation composite systems (ETICS) |
I.S. EN 15725:2010 | EXTENDED APPLICATION REPORTS ON THE FIRE PERFORMANCE OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS |
I.S. EN 15651-3:2017 | SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 3: SEALANTS FOR SANITARY JOINTS |
I.S. EN 15651-1:2017 | SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 1: SEALANTS FOR FACADE ELEMENTS |
UNI EN 16025-1 : 2013 | THERMAL AND/OR SOUND INSULATING PRODUCTS IN BUILDING CONSTRUCTION - BOUND EPS BALLASTINGS - PART 1: REQUIREMENTS FOR FACTORY PREMIXED EPS DRY PLASTER |
UNI EN 14319-1 : 2013 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
PREN 14307 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
UNE-CEN/TS 15912:2012 EX | Durability of reaction to fire performance - Classes of fire-retardant treated wood-based product in interior and exterior end use applications |
UNI EN 15498 : 2008 | PRECAST CONCRETE PRODUCTS - WOOD-CHIP CONCRETE SHUTTERING BLOCKS - PRODUCT PROPERTIES AND PERFORMANCE |
I.S. CEN TR 14819-2:2006 | SAFETY RECOMMENDATIONS FOR CABLEWAY INSTALLATIONS DESIGNED TO CARRY PERSONS - PREVENTION AND FIGHT AGAINST FIRE - PART 2: OTHER FUNICULAR RAILWAYS AND OTHER INSTALLATIONS |
EN 12004-1:2017 | Adhesives for ceramic tiles - Part 1: Requirements, assessment and verification of constancy of performance, classification and marking |
BS EN 13501-1 : 2007 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 1: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS |
UNE-EN 490:2012 | Concrete roofing tiles and fittings for roof covering and wall cladding - Product specifications |
I.S. EN 15498:2008 | PRECAST CONCRETE PRODUCTS - WOOD-CHIP CONCRETE SHUTTERING BLOCKS - PRODUCT PROPERTIES AND PERFORMANCE |
UNE-EN 14250:2010 | Timber structures - Product requirements for prefabricated structural members assembled with punched metal plate fasteners |
I.S. EN 14080:2013 | TIMBER STRUCTURES - GLUED LAMINATED TIMBER AND GLUED SOLID TIMBER - REQUIREMENTS |
I.S. EN ISO 1182:2010 | REACTION TO FIRE TESTS FOR PRODUCTS - NON-COMBUSTIBILITY TEST |
EN 13830:2015 | Curtain walling - Product standard |
EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
EN ISO 1182:2010 | Reaction to fire tests for products - Non-combustibility test (ISO 1182:2010) |
UNE-EN 12004:2008 | Adhesives for tiles - Requirements, evaluation of conformity, classification and designation |
I.S. EN 13823:2010 | REACTION TO FIRE TESTS FOR BUILDING PRODUCTS - BUILDING PRODUCTS EXCLUDING FLOORINGS EXPOSED TO THE THERMAL ATTACK BY A SINGLE BURNING ITEM |
EN 13501-1:2007+A1:2009 | Fire classification of construction products and building elements - Part 1: Classification using data from reaction to fire tests |
UNI EN ISO 1182 : 2010 | REACTION TO FIRE TESTS FOR PRODUCTS - NON-COMBUSTIBILITY TEST |
UNI EN 13823 : 2014 | REACTION TO FIRE TESTS FOR BUILDING PRODUCTS - BUILDING PRODUCTS EXCLUDING FLOORINGS EXPOSED TO THE THERMAL ATTACK BY A SINGLE BURNING ITEM |
UNI EN 14783 : 2013 | FULLY SUPPORTED METAL SHEET AND STRIP FOR ROOFING, EXTERNAL CLADDING AND INTERNAL LINING - PRODUCT SPECIFICATION AND REQUIREMENTS |
UNI EN 13859-2 : 2014 | FLEXIBLE SHEETS FOR WATERPROOFING - DEFINITIONS AND CHARACTERISTICS OF UNDERLAYS - PART 2: UNDERLAYS FOR WALLS |
UNI EN 12004 : 2012 | ADHESIVES FOR TILES - REQUIREMENTS, EVALUATION OF CONFORMITY, CLASSIFICATION AND DESIGNATION |
UNI EN 13859-1 : 2014 | FLEXIBLE SHEETS FOR WATERPROOFING - DEFINITIONS AND CHARACTERISTICS OF UNDERLAYS - PART 1: UNDERLAYS FOR DISCONTINUOUS ROOFING |
UNI EN 14080 : 2013 | TIMBER STRUCTURES - GLUED LAMINATED TIMBER AND GLUED SOLID TIMBER - REQUIREMENTS |
EN 490:2011+A1:2017 | Concrete roofing tiles and fittings for roof covering and wall cladding - Product specifications |
UNI EN 14250 : 2010 | TIMBER STRUCTURES - PRODUCT REQUIREMENTS FOR PREFABRICATED STRUCTURAL MEMBERS ASSEMBLED WITH PUNCHED METAL PLATE FASTENERS |
UNI EN ISO 9239-1 : 2010 | REACTION TO FIRE TESTS FOR FLOORINGS - PART 1: DETERMINATION OF THE BURNING BEHAVIOUR USING A RADIANT HEAT SOURCE |
UNI CEN/TS 1187 : 2012 | TEST METHODS FOR EXTERNAL FIRE EXPOSURE TO ROOFS |
UNI EN 491 : 2011 | CONCRETE ROOFING TILES AND FITTINGS FOR ROOF COVERING AND WALL CLADDING - TEST METHODS |
UNI EN 14879-6 : 2010 | ORGANIC COATING SYSTEMS AND LININGS FOR PROTECTION OF INDUSTRIAL APPARATUS AND PLANTS AGAINST CORROSION CAUSED BY AGGRESSIVE MEDIA - PART 6: COMBINED LININGS WITH TILE AND BRICK LAYERS |
DIN EN 14041:2016-07 (Draft) | RESILIENT, TEXTILE AND LAMINATE FLOOR COVERINGS - ESSENTIAL CHARACTERISTICS |
UNI EN 15725 : 2010 | EXTENDED APPLICATION REPORTS ON THE FIRE PERFORMANCE OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS |
DIN EN 16351:2015-12 | Timber structures - Cross laminated timber - Requirements |
11/30249114 DC : 0 | BS EN 15497 - STRUCTURAL FINGER JOINTED SOLID TIMBER - PERFORMANCE REQUIREMENTS AND MINIMUM PRODUCTION REQUIREMENTS |
BS EN ISO 25762:2012 | Plastics. Guidance on the assessment of the fire characteristics and fire performance of fibre-reinforced polymer composites |
I.S. EN 14314:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
BS EN 14319-1:2013 | Thermal insulating products for building equipment and industrial installations. In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products Specification for the rigid foam dispensed system before installation |
I.S. EN 12004:2007 | ADHESIVES FOR TILES - REQUIREMENTS, EVALUATION OF CONFORMITY, CLASSIFICATION AND DESIGNATION |
15/30315084 DC : DRAFT MAY 2015 | BS EN 14309 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
12/30254141 DC : 0 | BS EN 15651-4 - SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 4: SEALANTS FOR PEDESTRIAN WALKWAYS |
15/30315090 DC : DRAFT MAY 2015 | BS EN 14304 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION |
06/30155368 DC : 0 | PREN 14879-6 - ORGANIC COATING SYSTEMS AND LININGS FOR PROTECTION OF INDUSTRIAL APPARATUS AND PLANTS AGAINST CORROSION CAUSED BY AGGRESSIVE MEDIA - PART 6: COMBINED LININGS WITH TILE AND BRICK LAYERS |
05/30136552 DC : 0 | PREN 14304 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) - SPECIFICATION |
PREN 14303 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
UNI EN 14315-1 : 2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
UNI EN 14318-1 : 2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
PREN 15651-4 : DRAFT 2012 | SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 4: SEALANTS FOR PEDESTRIAN WALKWAYS |
17/30348262 DC : 0 | BS EN 13501-1 - FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 1: CLASSIFICATION USING TEST DATA FROM REACTION TO FIRE TESTS |
BS EN 14308:2015 | Thermal insulation products for building equipment and industrial installations. Factory made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products. Specification |
BS EN 14306:2015 | Thermal insulation products for building equipment and industrial installations. Factory made calcium silicate (CS) products. Specification |
14/30314738 DC : 0 | BS EN 12004-1 - ADHESIVES FOR TILES - PART 1: REQUIREMENTS, EVALUATION OF CONFORMITY, CLASSIFICATION AND DESIGNATION |
ISO/TR 17252:2008 | Fire tests Applicability of reaction to fire tests to fire modelling and fire safety engineering |
BS EN 14318-1:2013 | Thermal insulating products for buildings. In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products Specification for the rigid foam dispensed system before installation |
UNE-EN 12004-1:2017 | Adhesives for ceramic tiles - Part 1: Requirements, assessment and verification of constancy of performance, classification and marking |
UNE-EN 15651-3:2017 | Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 3: Sealants for sanitary joints |
11/30238644 DC : 0 | BS EN 490 - CONCRETE ROOFING TILES AND FITTINGS FOR ROOF COVERING AND WALL CLADDING - PRODUCT SPECIFICATIONS |
DIN EN 15814:2015-03 | POLYMER MODIFIED BITUMINOUS THICK COATINGS FOR WATERPROOFING - DEFINITIONS AND REQUIREMENTS |
PD CEN/TR 14819-1:2004 | Safety recommendations for cableway installations designed to carry persons. Prevention and fight against fire Funicular railways in tunnels |
12/30254132 DC : 0 | BS EN 15651-1 - SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 1: SEALANTS FOR FACADE ELEMENTS |
16/30340580 DC : 0 | BS EN 17009 - FLOORING OF LIGNIFIED MATERIALS OTHER THAN WOOD - CHARACTERISTICS, EVALUATION OF CONFORMITY AND MARKING |
07/30166918 DC : DRAFT AUG 2007 | BS EN 14064-1 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL MINERAL WOOL (MW) PRODUCTS - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
PREN 14904 : DRAFT 2015 | SURFACES FOR SPORTS AREAS - INDOOR SURFACES FOR MULTI-SPORTS USE - SPECIFICATION |
07/30172345 DC : 0 | BS EN 15724 - THERMOPLASTICS STATIC TANKS FOR ABOVE GROUND STORAGE OF DOMESTIC HEATING OILS, KEROSENE AND DIESEL FUELS - SECONDARY CONTAINMENTS USED WITH TANKS COMPLYING WITH EN 13341 - REQUIREMENTS AND TEST METHODS |
UNI CEI CEN/TS 45545-2 : 2009 | RAILWAY APPLICATIONS - FIRE PROTECTION OF RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
09/30193698 DC : DRAFT JAN 2009 | BS EN 14080 - TIMBER STRUCTURES - GLUED LAMINATED TIMBER AND GLUED LAMINATED SOLID TIMBER - REQUIREMENTS |
DIN EN 13501-1:2010-01 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 1: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS |
DIN EN 45545-2:2016-02 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
PREN 15651-2 : DRAFT 2012 | SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 2: SEALANTS FOR GLAZING |
UNE-EN 14308:2017 | Thermal insulation products for building equipment and industrial installations - Factory made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products - Specification |
UNE-EN 15814:2011 | Polymer modified bituminous thick coatings for waterproofing - Definitions and requirements |
BS EN ISO 1716:2010 | Reaction to fire tests for products. Determination of the gross heat of combustion (calorific value) |
DD CEN/TS 45545-2:2009 | Railway applications. Fire protection on railway vehicles Requirements for fire behaviour of materials and components |
I.S. EN 16733:2016 | REACTION TO FIRE TESTS FOR BUILDING PRODUCTS - DETERMINATION OF A BUILDING PRODUCT'S PROPENSITY TO UNDERGO CONTINUOUS SMOULDERING |
PREN 15101-1 : DRAFT 2013 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
BS EN 14305:2015 | Thermal insulation products for building equipment and industrial installations. Factory made cellular glass (CG) products. Specification |
UNE-EN 15715:2012 | Thermal insulation products - Instructions for mounting and fixing for reaction to fire testing - Factory made products |
I.S. EN 14879-6:2009 | ORGANIC COATING SYSTEMS AND LININGS FOR PROTECTION OF INDUSTRIAL APPARATUS AND PLANTS AGAINST CORROSION CAUSED BY AGGRESSIVE MEDIA - PART 6: COMBINED LININGS WITH TILE AND BRICK LAYERS |
I.S. EN ISO 25762:2012 | PLASTICS - GUIDANCE ON THE ASSESSMENT OF THE FIRE CHARACTERISTICS AND FIRE PERFORMANCE OF FIBRE-REINFORCED POLYMER COMPOSITES (ISO 25762:2009) |
PREN 15102 : DRAFT 2016 | DECORATIVE WALLCOVERINGS - ROLL FORM |
UNI EN 15102 : 2011 | DECORATIVE WALL COVERINGS - ROLL AND PANEL FORM |
I.S. EN 16724:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING APPLICATIONS - INSTRUCTIONS FOR MOUNTING AND FIXING FOR DETERMINATION OF THE REACTION TO FIRE TESTING OF EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS (ETICS) |
14/30311487 DC : 0 | BS EN 14188-2 - JOINT FILLERS AND SEALANTS - PART 2: SPECIFICATIONS FOR COLD APPLIED SEALANTS |
14/30311128 DC : 0 | BS EN 14716 - STRETCHED CEILINGS - REQUIREMENTS AND TEST METHODS |
PREN 14904-2 : DRAFT 2017 | SURFACES FOR SPORTS AREAS - MULTI-SPORTS FLOOR SYSTEMS FOR INDOOR USE - PART 2: SPECIFICATIONS |
PREN 14041 : DRAFT 2016 | RESILIENT, TEXTILE AND LAMINATE FLOOR COVERINGS - ESSENTIAL CHARACTERISTICS |
EN ISO 1716:2010 | Reaction to fire tests for products - Determination of the gross heat of combustion (calorific value) (ISO 1716:2010) |
I.S. EN 14308:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - SPECIFICATION |
I.S. EN 14313:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
DIN EN 13823:2015-02 | REACTION TO FIRE TESTS FOR BUILDING PRODUCTS - BUILDING PRODUCTS EXCLUDING FLOORINGS EXPOSED TO THE THERMAL ATTACK BY A SINGLE BURNING ITEM |
I.S. CEN/TS 15447:2006 | MOUNTING AND FIXING IN REACTION TO FIRE TESTS UNDER THE CONSTRUCTION PRODUCTS DIRECTIVE |
BS EN 13823:2010+A1:2014 | Reaction to fire tests for building products. Building products excluding floorings exposed to the thermal attack by a single burning item |
DIN EN 14081-1:2016-06 | TIMBER STRUCTURES - STRENGTH GRADED STRUCTURAL TIMBER WITH RECTANGULAR CROSS SECTION - PART 1: GENERAL REQUIREMENTS |
DIN EN 14080:2013-09 | TIMBER STRUCTURES - GLUED LAMINATED TIMBER AND GLUED SOLID TIMBER - REQUIREMENTS |
BS EN 14904:2006 | Surfaces for sports areas. Indoor surfaces for multi-sports use. Specification |
UNE-EN ISO 11925-2:2011 | Reaction to fire tests - Ignitability of products subjected to direct impingement of flame - Part 2: Single-flame source test (ISO 11925-2:2010) |
BS EN 12004 : 2007 | ADHESIVES FOR TILES - REQUIREMENTS, EVALUATION OF CONFORMITY, CLASSIFICATION AND DESIGNATION |
DIN EN 14904:2015-09 (Draft) | SURFACES FOR SPORTS AREAS - INDOOR SURFACES FOR MULTI-SPORTS USE - SPECIFICATION |
UNE-EN 16351:2016 | Timber structures - Cross laminated timber - Requirements |
BS EN ISO 11925-2:2010 | Reaction to fire tests. Ignitability of products subjected to direct impingement of flame Single-flame source test |
BS EN 15102 : 2007 | DECORATIVE WALL COVERINGS - ROLL AND PANEL FORM |
I.S. EN ISO 11925-2:2010 | REACTION TO FIRE TESTS - IGNITABILITY OF BUILDING PRODUCTS SUBJECTED TO DIRECT IMPINGEMENT OF FLAME - PART 2: SINGLE-FLAME SOURCE TEST |
UNE-EN 14081-1:2016 | Timber structures - Strength graded structural timber with rectangular cross section - Part 1: General requirements |
BS EN 14879-3:2006 | Organic coating systems and linings for protection of industrial apparatus and plants against corrosion caused by aggressive media Coatings on concrete components |
BS EN 14783:2013 | Fully supported metal sheet and strip for roofing, external cladding and internal lining. Product specification and requirements |
DIN EN 14783:2013-07 | FULLY SUPPORTED METAL SHEET AND STRIP FOR ROOFING, EXTERNAL CLADDING AND INTERNAL LINING - PRODUCT SPECIFICATION AND REQUIREMENTS |
BS EN 14351-1 : 2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS |
BS EN 14250:2010 | Timber structures. Product requirements for prefabricated structural members assembled with punched metal plate fasteners |
BS EN 13830:2015 | Curtain walling. Product standard |
BS EN 14080:2013 | Timber structures. Glued laminated timber and glued solid timber. Requirements |
BS EN ISO 1182:2010 | Reaction to fire tests for products. Non-combustibility test |
BS EN 13500:2003 | Thermal insulation products for buildings. External thermal insulation composite systems (ETICS) based on mineral wool. Specification |
ISO 25762:2009 | Plastics Guidance on the assessment of the fire characteristics and fire performance of fibre-reinforced polymer composites |
UNE-EN ISO 9239-1:2011 | Reaction to fire tests for floorings - Part 1: Determination of the burning behaviour using a radiant heat source (ISO 9239-1:2010) |
EN 14308:2015 | Thermal insulation products for building equipment and industrial installations - Factory made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products - Specification |
EN 15651-2:2017 | Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 2: Sealants for glazing |
EN 14879-3:2006 | Organic coating systems and linings for protection of industrial apparatus and plants against corrosion caused by aggressive media - Part 3: Coatings on concrete components |
EN 14306:2015 | Thermal insulation products for building equipment and industrial installations - Factory made calcium silicate (CS) products - Specification |
EN 14319-1:2013 | Thermal insulating products for building equipment and industrial installations - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products - Part 1: Specification for the rigid foam dispensed system before installation |
EN 14305:2015 | Thermal insulation products for building equipment and industrial installations - Factory made cellular glass (CG) products - Specification |
EN 14904:2006 | Surfaces for sports areas - Indoor surfaces for multi-sports use - Specification |
EN 14080:2013 | Timber structures - Glued laminated timber and glued solid timber - Requirements |
EN 13859-1:2014 | Flexible sheets for waterproofing - Definitions and characteristics of underlays - Part 1: Underlays for discontinuous roofing |
EN 13859-2:2014 | Flexible sheets for waterproofing - Definitions and characteristics of underlays - Part 2: Underlays for walls |
EN 14307:2015 | Thermal insulation products for building equipment and industrial installations - Factory made extruded polystyrene foam (XPS) products - Specification |
EN 15498:2008 | Precast concrete products - Wood-chip concrete shuttering blocks - Product properties and performance |
EN 15814:2011+A2:2014 | Polymer modified bituminous thick coatings for waterproofing - Definitions and requirements |
EN ISO 9239-1:2010 | Reaction to fire tests for floorings - Part 1: Determination of the burning behaviour using a radiant heat source (ISO 9239-1:2010) |
EN 14309:2015 | Thermal insulation products for building equipment and industrial installations - Factory made products of expanded polystyrene (EPS) - Specification |
EN 14351-1:2006+A2:2016 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets |
EN 14081-1:2016 | Timber structures - Strength graded structural timber with rectangular cross section - Part 1: General requirements |
EN 14879-6:2009 | Organic coating systems and linings for protection of industrial apparatus and plants against corrosion caused by aggressive media - Part 6: Combined linings with tile and brick layers |
EN 16623:2015 | Paints and varnishes - Reactive coatings for fire protection of metallic substrates - Definitions, requirements, characteristics and marking |
EN 14716:2004 | Stretched ceilings - Requirements and test methods |
EN 14320-1:2013 | Thermal insulating products for building equipment and industrial installations - In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products - Part 1: Specification for the rigid foam spray system before installation |
EN 15651-3:2017 | Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 3: Sealants for sanitary joints |
EN 14304:2015 | Thermal insulation products for building equipment and industrial installations - Factory made flexible elastomeric foam (FEF) products - Specification |
EN 16724:2015 | Thermal insulation products for building applications - Instructions for mounting and fixing for determination of the reaction to fire testing of external thermal Insulation composite systems (ETICS) |
EN 14390:2007 | Fire test - Large-scale room reference test for surface products |
EN 15497:2014 | Structural finger jointed solid timber - Performance requirements and minimum production requirements |
EN ISO 25762:2012 | Plastics - Guidance on the assessment of the fire characteristics and fire performance of fibre-reinforced polymer composites (ISO 25762:2009) |
EN 14315-1:2013 | Thermal insulating products for buildings - In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam spray system before installation |
EN 16733:2016 | Reaction to fire tests for building products - Determination of a building product's propensity to undergo continuous smouldering |
EN 15715:2009 | Thermal insulation products - Instructions for mounting and fixing for reaction to fire testing - Factory made products |
EN 14314:2015 | Thermal insulation products for building equipment and industrial installations - Factory made phenolic foam (PF) products - Specification |
EN 491:2011 | Concrete roofing tiles and fittings for roof covering and wall cladding - Test methods |
EN 14318-1:2013 | Thermal insulating products for buildings - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam dispensed system before installation |
EN 14313:2015 | Thermal insulation products for building equipment and industrial installations - Factory made polyethylene foam (PEF) products - Specification |
EN 14783:2013 | Fully supported metal sheet and strip for roofing, external cladding and internal lining - Product specification and requirements |
EN 14303:2015 | Thermal insulation products for building equipment and industrial installations - Factory made mineral wool (MW) products - Specification |
EN 16025-1:2013 | Thermal and/or sound insulating products in building construction - Bound EPS ballastings - Part 1: Requirements for factory premixed EPS dry plaster |
EN 15651-1:2017 | Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 1: Sealants for facade elements |
I.S. EN 16755:2017 | DURABILITY OF REACTION TO FIRE PERFORMANCE - CLASSES OF FIRE-RETARDANT TREATED WOOD PRODUCTS IN INTERIOR AND EXTERIOR END USE APPLICATIONS |
14/30300561 DC : 0 | BS EN 16755 - DURABILITY OF REACTION TO FIRE PERFORMANCE - CLASSES OF FIRERETARDANT TREATED WOOD PRODUCTS IN INTERIOR AND EXTERIOR END USE APPLICATIONS |
PREN 14716 : DRAFT 2014 | STRETCHED CEILINGS - REQUIREMENTS AND TEST METHODS |
DIN EN 14318-1:2013-04 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
DIN EN 15102:2016-02 (Draft) | DECORATIVE WALL COVERINGS - ROLL AND PANEL FORM |
I.S. EN 16351:2015 | TIMBER STRUCTURES - CROSS LAMINATED TIMBER - REQUIREMENTS |
PREN 13501-1 : DRAFT 2017 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 1: CLASSIFICATION USING TEST DATA FROM REACTION TO FIRE TESTS |
PREN 15651-1 : DRAFT 2012 | SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 1: SEALANTS FOR FACADE ELEMENTS |
UNE-EN 15497:2014 | Structural finger jointed solid timber - Performance requirements and minimum production requirements |
I.S. EN 16623:2015 | PAINTS AND VARNISHES - REACTIVE COATINGS FOR FIRE PROTECTION OF METALLIC SUBSTRATES - DEFINITIONS, REQUIREMENTS, CHARACTERISTICS AND MARKING |
12/30254135 DC : 0 | BS EN 15651-2 - SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 2: SEALANTS FOR GLAZING |
ISO 1716:2010 | Reaction to fire tests for products Determination of the gross heat of combustion (calorific value) |
DD CEN/TS 15447:2006 | Mounting and fixing in reaction to fire tests under the Construction Products Directive |
13/30288842 DC : 0 | BS EN 14081-1 - TIMBER STRUCTURES - STRENGTH GRADED STRUCTURAL TIMBER WITH RECTANGULAR CROSS SECTION - PART 1: GENERAL REQUIREMENTS |
08/30154274 DC : DRAFT MAR 2008 | BS ISO 25762 - PLASTICS - GUIDANCE ON THE ASSESSMENT OF FIRE CHARACTERISTICS AND FIRE PERFORMANCE OF FIBRE-REINFORCED COMPOSITES |
PREN 491 : DRAFT 2011 | CONCRETE ROOFING TILES AND FITTINGS FOR ROOF COVERING AND WALL CLADDING - TEST METHODS |
DIN EN 14319-1:2013-04 | Thermal insulating products for building equipment and industrial installations - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam dispensed system before installation |
05/30136538 DC : 0 | PREN 14307 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
DIN EN 12004-1:2015-02 (Draft) | ADHESIVES FOR CERAMIC TILES - PART 1: REQUIREMENTS, ASSESSMENT AND VERIFICATION OF CONSTANCY OF PERFORMANCE, CLASSIFICATION AND MARKING |
UNE-EN 16025-1:2016 | Thermal and/or sound insulating products in building construction - Bound EPS ballastings - Part 1: Requirements for factory premixed EPS dry plaster |
UNE-EN 14319-1:2013 | Thermal insulating products for building equipment and industrial installations - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products - Part 1: Specification for the rigid foam dispensed system before installation |
15/30315093 DC : DRAFT MAY 2015 | BS EN 14303 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
13/30268273 DC : 0 | BS EN 14915 - SOLID WOOD PANELLING AND CLADDING - CHARACTERISTICS, EVALUATION OF CONFORMITY AND MARKING |
04/30123574 DC : DRAFT OCT 2004 | EN 14879-3 - ORGANIC COATING SYSTEMS AND LININGS FOR PROTECTION OF INDUSTRIAL APPARATUS AND PLANTS AGAINST CORROSION CAUSED BY AGGRESSIVE MEDIA - PART 3: COATINGS ON CONCRETE COMPONENTS |
PD CEN/TS 16354:2013 | Laminate floor coverings. Underlays. Specification, requirements and test methods |
12/30254138 DC : 0 | BS EN 15651-3 - SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 3: SEALANTS FOR SANITARY JOINTS |
08/30171902 DC : 0 | BS EN ISO 1182 - REACTION TO FIRE TESTS FOR BUILDING PRODUCTS - NON-COMBUSTIBILITY TEST |
09/30207868 DC : 0 | BS EN 13859-2 - FLEXIBLE SHEETS FOR WATERPROOFING - DEFINITIONS AND CHARACTERISTICS OF UNDERLAYS - PART 2: UNDERLAYS FOR WALLS |
08/30171906 DC : 0 | BS EN ISO 1716 - REACTION TO FIRE TESTS FOR BUILDING PRODUCTS - DETERMINATION OF THE HEAT OF COMBUSTION |
07/30164611 DC : 0 | BS EN 15651-2 - SEALANTS FOR JOINTS IN BUILDING CONSTRUCTION - DEFINITIONS, REQUIREMENTS AND EVALUATION OF CONFORMITY - PART 2: SEALANTS FOR GLAZING |
BS ISO 14697:2007 | Reaction-to-fire tests. Guidance on the choice of substrates for building and transport products |
04/30126127 DC : 0 | EN 15102 - DECORATIVE WALLCOVERINGS - ROLL AND PANEL FORM |
I.S. EN 14315-1:2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
UNE-EN 15651-2:2017 | Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 2: Sealants for glazing |
UNE-EN 14315-1:2013 | Thermal insulating products for buildings. In-situ formed sprayed rigid polyurethane foam (PUR) products. Part 1: Specification for the rigid foam spray system before installation |
UNE-EN 15102:2008 | Decorative wallcoverings - Roll and panel form products |
03/310127 DC : DRAFT JUNE 2003 | EN 14716 - STRETCHED CEILINGS - REQUIREMENTS AND TEST METHODS |
07/30163692 DC : 0 | BS EN 15651-3 - SEALANTS FOR JOINTS IN BUILDING CONSTRUCTION - DEFINITIONS, REQUIREMENTS AND EVALUATION OF CONFORMITY - PART 3: SEALANTS FOR SANITARY JOINTS |
UNE-EN 45545-2:2013 | Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behavior of materials and components |
UNE-EN 15101-1:2015 | Thermal insulation products for buildings - In-situ formed loose fill cellulose (LFCI) products - Part 1: Specification for the products before installation |
UNI EN 13501-1 : 2009 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 1: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS |
BS EN 15101-1:2013 | Thermal insulation products for buildings. In-situ formed loose fill cellulose (LFCI) products Specification for the products before installation |
BS EN 15651-1:2017 | Sealants for non-structural use in joints in buildings and pedestrian walkways Sealants for facade elements |
I.S. EN 14318-1:2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
UNE-EN 16755:2018 | Durability of reaction to fire performance - Classes of fire-retardant treated wood products in interior and exterior end use applications |
S.R. CEN/TS 16354:2013 | LAMINATE FLOOR COVERINGS - UNDERLAYS - SPECIFICATION, REQUIREMENTS AND TEST METHODS |
BS EN 14313 : 2009 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
14/30295898 DC : 0 | BS EN 14904 - SURFACES FOR SPORTS AREAS - INDOOR SURFACES FOR MULTI-SPORTS USE - SPECIFICATION |
17/30353879 DC : 0 | BS EN 17104 - THERMOPLASTICS RIGID PROTECTIVE WALLCOVERING PANELS FOR INTERNAL USE IN BUILDINGS - PERFORMANCE CHARACTERISTICS |
PREN 15651-3 : DRAFT 2012 | SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 3: SEALANTS FOR SANITARY JOINTS |
DIN EN 16724:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING APPLICATIONS - INSTRUCTIONS FOR MOUNTING AND FIXING FOR DETERMINATION OF THE REACTION TO FIRE TESTING OF EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS (ETICS) |
I.S. EN 14307:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
BS EN 13823 : 2010 | REACTION TO FIRE TESTS FOR BUILDING PRODUCTS - BUILDING PRODUCTS EXCLUDING FLOORINGS EXPOSED TO THE THERMAL ATTACK BY A SINGLE BURNING ITEM |
ISO 11925-2:2010 | Reaction to fire tests Ignitability of products subjected to direct impingement of flame Part 2: Single-flame source test |
DIN EN 13859-2:2014-07 | FLEXIBLE SHEETS FOR WATERPROOFING - DEFINITIONS AND CHARACTERISTICS OF UNDERLAYS - PART 2: UNDERLAYS FOR WALLS |
DIN EN 490:2012-01 | CONCRETE ROOFING TILES AND FITTINGS FOR ROOF COVERING AND WALL CLADDING - PRODUCT SPECIFICATIONS |
UNI EN ISO 11925-2 : 2010 | REACTION TO FIRE TESTS - IGNITABILITY OF PRODUCTS SUBJECTED TO DIRECT IMPINGEMENT OF FLAME - PART 2: SINGLE-FLAME SOURCE TEST |
BS EN 14915 : 2013 | SOLID WOOD PANELLING AND CLADDING - CHARACTERISTICS, EVALUATION OF CONFORMITY AND MARKING |
BS EN 14081-1:2016 | Timber structures. Strength graded structural timber with rectangular cross section General requirements |
ISO 1182:2010 | Reaction to fire tests for products Non-combustibility test |
BS EN 490 : 2011 | CONCRETE ROOFING TILES AND FITTINGS FOR ROOF COVERING AND WALL CLADDING - PRODUCT SPECIFICATIONS |
BS EN ISO 9239-1:2010 | Reaction to fire tests for floorings Determination of the burning behaviour using a radiant heat source |
BS EN 13859-1:2014 | Flexible sheets for waterproofing. Definitions and characteristics of underlays Underlays for discontinuous roofing |
DIN EN 15651-3:2017-07 | SEALANTS FOR NON-STRUCTURAL USE IN JOINTS IN BUILDINGS AND PEDESTRIAN WALKWAYS - PART 3: SEALANTS FOR SANITARY JOINTS |
DIN EN 491:2011-11 | Concrete roofing tiles and fittings for roof covering and wall cladding - Test methods |
CEN/TS 1187:2012 | Test methods for external fire exposure to roofs |
DIN EN 14879-3:2007-02 | Organic coating systems and linings for protection of industrial apparatus and plants against corrosion caused by aggressive media - Part 3: Coatings on concrete components |
CEN/TS 15447:2006 | Mounting and fixing in reaction to fire tests under the Construction Products Directive |
DIN EN 14915:2013-12 | SOLID WOOD PANELLING AND CLADDING - CHARACTERISTICS, REQUIREMENTS AND MARKING |
CEN/TS 45545-2:2009 | Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behaviour of materials and components |
CEN/TS 15117:2005 | Guidance on direct and extended application |
CEN/TS 15912:2012 | Durability of reaction to fire performance - Classes of fire-retardant treated wood-based product in interior and exterior end use applications |
DIN EN 490:2017-04 | Concrete roofing tiles and fittings for roof covering and wall cladding - Product specifications (includes Amendment :2017) |
DIN EN ISO 11925-2:2011-02 | REACTION TO FIRE TESTS - IGNITABILITY OF PRODUCTS SUBJECTED TO DIRECT IMPINGEMENT OF FLAME - PART 2: SINGLE-FLAME SOURCE TEST |
UNE-EN 13823:2012 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
UNE-EN 14915:2013 | Solid wood panelling and cladding - Characteristics, evaluation of conformity and marking |
UNE-EN 14351-1:2006 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics |
EN 520:2004+A1:2009 | Gypsum plasterboards - Definitions, requirements and test methods |
ISO 1716:2010 | Reaction to fire tests for products Determination of the gross heat of combustion (calorific value) |
ISO 11925-2:2010 | Reaction to fire tests Ignitability of products subjected to direct impingement of flame Part 2: Single-flame source test |
EN ISO 1182:2010 | Reaction to fire tests for products - Non-combustibility test (ISO 1182:2010) |
ISO 13943:2017 | Fire safety — Vocabulary |
EN 312:2010 | Particleboards - Specifications |
ISO 1182:2010 | Reaction to fire tests for products Non-combustibility test |
EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
EN 14306:2015 | Thermal insulation products for building equipment and industrial installations - Factory made calcium silicate (CS) products - Specification |
EN ISO 9239-1:2010 | Reaction to fire tests for floorings - Part 1: Determination of the burning behaviour using a radiant heat source (ISO 9239-1:2010) |
EN 14390:2007 | Fire test - Large-scale room reference test for surface products |
ISO 390:1993 | Products in fibre-reinforced cement Sampling and inspection |
ISO 1887:2014 | Textile glass Determination of combustible-matter content |
EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
ISO 554:1976 | Standard atmospheres for conditioning and/or testing — Specifications |
ISO 9239-1:2010 | Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source |
EN 636:2012+A1:2015 | Plywood - Specifications |
EN ISO 1716:2010 | Reaction to fire tests for products - Determination of the gross heat of combustion (calorific value) (ISO 1716:2010) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.