EN 13203-3:2010
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Solar supported gas-fired domestic appliances producing hot water - Appliances not exceeding 70 kW heat input and 500 litres water storage capacity - Part 3: Assessment of energy consumption
02-28-2011
08-11-2010
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 General test conditions
5 Determination of the energy consumption of the solar
supported gas-fired appliance
Annex A (informative) - Test rig and measurement devices
Annex B (informative) - Solar collector simulator
Annex C (normative) - Appliances covered by this European
Standard
Bibliography
This European Standard is applicable to solar supported gas-fired appliances producing domestic hot water. It applies to a system marketed as single unit or a system fully specified by a manufacturer that:-has a gas heat input not exceeding 70 kW; and-has a hot water storage capacity not exceeding 500 l; and-is equipped with at least one solar collector; and-is, with regard to the solar hydraulic circuit, considered as a forced circulation system (definition according to EN ISO 9488:1999).The appliances covered by this European Standard are described in Annex C.This European Standard does not apply to thermo-siphon or integral collector storage systems (definitions according to EN ISO 9488:1999). NOTEIn principle, the energy consumption of thermo-siphon solar preheat systems and integral collector storage preheat systems can also be assessed on the basis of this standard. One appropriate procedure for that purpose is to calculate the temperature level of the domestic hot water withdrawn from the thermal solar system for the reference conditions defined in this standard by using the numerical system model and the thermal solar system performance parameters according to ISO 9459-5. Based on the temperature level of the hot water withdrawn from the store the energy consumption of the gas appliance should be determined. This determination can either be done by means of calculations or by performing a test according to EN 13203-2 and using instead of the cold water inlet temperature the hot water temperature withdrawn from the store.This standard is not intended to assess the performance:-of the solar collector(s), which should comply with EN 12975-1 and EN 12975-2; and -thermal solar systems and components, which should comply with EN 12976-1 and EN 12976-2.(...)
Committee |
CEN/TC 109
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
Standards | Relationship |
NS EN 13203-3 : 1ED 2010 | Identical |
PN EN 13203-3 : 2010 | Identical |
UNI EN 13203-3 : 2010 | Identical |
UNE-EN 13203-3:2011 | Identical |
DIN EN 13203-3:2010-12 | Identical |
NF EN 13203-3 : 2010 | Identical |
SN EN 13203-3:2010 | Identical |
NBN EN 13203-3 : 2010 | Identical |
NEN EN 13203-3 : 2010 | Identical |
I.S. EN 13203-3:2010 | Identical |
ONORM EN 13203-3 : 2010 | Identical |
BS EN 13203-3:2010 | Identical |
ISO 9488:1999 | Solar energy Vocabulary |
EN 89:2015 | Gas-fired storage water heaters for the production of domestic hot water |
EN 13203-1:2015 | Gas fired domestic appliances producing hot water - Part 1: Assessment of performance of hot water deliveries |
EN 13203-2:2015 | Gas-fired domestic appliances producing hot water - Part 2: Assessment of energy consumption |
EN 12975-1:2006+A1:2010 | Thermal solar systems and components - Solar collectors - Part 1: General requirements |
EN ISO 9488:1999 | Solar energy - Vocabulary (ISO 9488:1999) |
EN 12976-2:2017 | Thermal solar systems and components - Factory made systems - Part 2: Test methods |
EN 26:2015 | Gas-fired instantaneous water heaters for the production of domestic hot water |
EN 12975-2:2006 | Thermal solar systems and components - Solar collectors - Part 2: Test methods |
EN 625:1995 | Gas-fired central heating boilers - Specific requirements for the domestic hot water operation of combination boilers of nominal heat input not exceeding 70 kW |