EN 12337-2:2004
Current
The latest, up-to-date edition.
Glass in building - Chemically strengthened soda lime silicate glass - Part 2: Evaluation of conformity/Product standard
10-13-2004
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
4.1 Product description
4.2 Conformity with the definition of chemically strengthened
soda lime silicate glass
4.3 Determination of the characteristic's performances
4.3.1 Characteristics of chemically strengthened soda
lime silicate safety glass
4.3.2 Determination of characteristics of chemically
strengthened soda lime silicate glass products
4.4 Durability
4.5 Dangerous substances
5 Evaluation of conformity
5.1 General
5.2 Initial type testing of the product
5.2.1 General
5.2.2 Initial type testing of chemically strengthened
soda lime silicate glass
5.2.3 Initial type testing of characteristic's performances
5.3 Factory production control and inspection of samples in
accordance with a prescribed test plan
5.4 Initial inspection of factory and of factory production
control
5.5 Continuous surveillance and assessment of the factory
production control
6 Marking and/or labelling
6.1 General
6.2 Product marking
6.3 Product characteristics
6.4 "Characteristics/performance identification paper"
Annex A (normative) Factory production control
A.1 Factory Production Control Requirements
A.1.1 General
A.1.2 Organisation
A.1.3 Control system
A.2 Marking
A.3 Inspection and testing tables of chemically strengthened
soda lime silicate glass production
A.3.1 Information on Table A.1
A.3.2 Use of proxy testing
Annex B (informative) Test methods for factory production control
- Strength Measurement
B.1 Four point bending strength test
B.1.1 Requirements
B.1.2 Measurement method
B.1.3 Test specimens
B.2 Alternative mechanical strength test methods
B.2.1 Three point bending strength test
B.2.2 Concentric bending ring strength test
Annex C (informative) Provisions for voluntary involvement of
third party(ies)
C.1 General
C.2 Voluntary tasks for third parties
C.3 Marking and labelling
Annex ZA (informative) Clauses of this European Standard
addressing the provisions of EU
Construction Products Directive
ZA.1 Scope and relevant characteristics
ZA.2 Procedure(s) for the attestation of conformity of
chemically strengthened soda lime silicate glass
products
ZA.2.1 System(s) of attestation of conformity
ZA.2.2 EC Certificate and Declaration of conformity
ZA.3 CE marking and labelling
Bibliography
This document covers the evaluation of conformity and the factory production control of flat chemically strengthened soda lime silicate glass for use in buildings. Note: For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.
Committee |
CEN/TC 129
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
NF EN 12337-2 : 2005 | Identical |
NBN EN 12337-2 : 2005 | Identical |
NEN EN 12337-2 : 2004 | Identical |
NS EN 12337-2 : 1ED 2005 | Identical |
I.S. EN 12337-2:2004 | Identical |
PN EN 12337-2 : 2009 | Identical |
SN EN 12337-2 : 2004 | Identical |
UNI EN 12337-2 : 2005 | Identical |
BS EN 12337-2:2004 | Identical |
UNE-EN 12337-2:2006 | Identical |
DIN EN 12337-2:2005-01 | Identical |
PREN 15254-4 : DRAFT 2016 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
DIN EN 15254-4:2013-10 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
DIN EN 13022-2:2014-08 | GLASS IN BUILDING - STRUCTURAL SEALANT GLAZING - PART 2: ASSEMBLY RULES |
UNE-EN 13022-2:2015 | Glass in building - Structural sealant glazing - Part 2: Assembly rules |
EN 13022-2:2014 | Glass in building - Structural sealant glazing - Part 2: Assembly rules |
EN 15254-4:2008+A1:2011 | Extended application of results from fire resistance tests - Non-loadbearing walls - Part 4: Glazed constructions |
I.S. EN 14351-1:2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND/OR SMOKE LEAKAGE CHARACTERISTICS |
I.S. EN 13022-2:2014 | GLASS IN BUILDING - STRUCTURAL SEALANT GLAZING - PART 2: ASSEMBLY RULES |
I.S. EN 14600:2005 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
05/30134012 DC : 0 | EN 15254-4 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTION |
BS EN 14600:2005 | Doorsets and openable windows with fire resisting and/ or smoke control characteristics. Requirements and classification |
UNI EN 14600 : 2006 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
UNI EN 13022-2 : 2014 | GLASS IN BUILDING - STRUCTURAL SEALANT GLAZING - PART 2: ASSEMBLY RULES |
BS EN 14351-1 : 2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS |
EN 14351-1:2006+A2:2016 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets |
EN 14600:2005 | Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification |
16/30347433 DC : 0 | BS EN 15254-4 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
UNI EN 15254-4 : 2011 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
UNE-EN 15254-4:2009 | Extended application of results from fire resistance tests - Non-loadbearing walls - Part 4: Glazed constructions |
BS EN 15254-4 : 2008 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
I.S. EN 15254-4:2008 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
BS EN 13022-2:2014 | Glass in building. Structural sealant glazing Assembly rules |
DIN EN 14600:2006-03 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
UNE-EN 14351-1:2006 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics |
PREN 13501-5 : DRAFT 2015 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 5: CLASSIFICATION USING DATA FROM EXTERNAL FIRE EXPOSURE TO ROOFS TESTS |
EN 12337-1:2000 | Glass in building - Chemically strengthened soda lime silicate glass - Part 1: Definition and description |
EN 673:2011 | Glass in building - Determination of thermal transmittance (U value) - Calculation method |
EN 12758:2011 | Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties |
EN 410:2011 | Glass in building - Determination of luminous and solar characteristics of glazing |
EN 12898:2001 | Glass in building - Determination of the emissivity |
EN 13541:2012 | Glass in building - Security glazing - Testing and classification of resistance against explosion pressure |
EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
EN 1288-3:2000 | Glass in building - Determination of the bending strength of glass - Part 3: Test with specimen supported at two points (four point bending) |
EN 572-2:2012 | Glass in building - Basic soda lime silicate glass products - Part 2: Float glass |
EN 1288-5:2000 | Glass in building - Determination of the bending strength of glass - Part 5: Coaxial double ring test on flat specimens with small test surface areas |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 1063:1999 | Glass in building - Security glazing - Testing and classification of resistance against bullet attack |
EN 572-4:2012 | Glass in building - Basic soda lime silicate glass products - Part 4: Drawn sheet glass |
EN 357:2004 | Glass in building - Fire resistant glazed elements with transparent or translucent glass products - Classification of fire resistance |
ISO 9001:2015 | Quality management systems — Requirements |
EN 572-1:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties |
EN 356:1999 | Glass in building - Security glazing - Testing and classification of resistance against manual attack |
EN 572-5:2012 | Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass |
EN 12600:2002 | Glass in building - Pendulum test - Impact test method and classification for flat glass |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.