EN 12150-1:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Glass in building - Thermally toughened soda lime silicate safety glass - Part 1: Definition and description
05-30-2019
09-23-2015
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Glass products
5 Fracture characteristics
6 Dimensions and tolerances
7 Edge and/or surface work, holes, notches and cut-outs
8 Fragmentation test
9 Other physical characteristics
10 Marking
Annex A (informative) - Curved thermally toughened soda
lime silicate safety glass
Annex B (informative) - Alternative method for the
measurement of roller wave distortion
Annex C (informative) - Examples of particle count
Annex D (informative) - Risk of spontaneous breakage
of toughened glass due to nickel sulfide inclusion
Bibliography
This European Standard specifies tolerances, flatness, edgework, fragmentation and physical and mechanical characteristics of monolithic flat thermally toughened soda lime silicate safety glass for use in buildings.Information on curved thermally toughened soda lime silicate safety glass is given in Annex A, but this product does not form part of this European Standard.Other requirements, not specified in this European Standard, can apply to thermally toughened soda lime silicate safety glass which is incorporated into assemblies, e.g. laminated glass or insulating glass units, or undergo an additional treatment, e.g. coating. The additional requirements are specified in the appropriate glass product standard. Thermally toughened soda lime silicate safety glass, in this case, does not lose its bending strength characteristics and its resistance to temperature differentials.Surface finished glasses (e.g. sandblasted, acid etched) after toughening are not covered by this European Standard.
Committee |
CEN/TC 129
|
DevelopmentNote |
Supersedes PREN 12150-1. (09/2015)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NS EN 12150-1 : 2000 | Identical |
NBN EN 12150-1 : 2015 | Identical |
SN EN 12150-1 : 2015 | Identical |
DIN EN 12150-1:2015-12 | Identical |
UNI EN 12150-1 : 2001 | Identical |
I.S. EN 12150-1:2015 | Identical |
I.S. EN 12150-1:2015+A1:2019 | Identical |
NEN-EN 12150-1: 2015 + A1: 2019 | Identical |
BS EN 12150-1:2015 | Identical |
PN EN 12150-1 : 2015 | Identical |
BS EN 12150-1:2015+A1:2019 | Identical |
UNE-EN 12150-1:2016 | Identical |
ONORM EN 12150-1 : 2015 | Identical |
NF EN 12150-1 : 2015 | Identical |
SS-EN 12150-1:2015 | Identical |
NEN EN 12150-1 : 2015 | Identical |
UNI EN 15755-1 : 2015 | GLASS IN BUILDING - ADHESIVE BACKED POLYMERIC FILMED GLASS - PART 1: DEFINITIONS AND REQUIREMENTS |
12/30235100 DC : DRAFT JAN 2012 | BS EN 14428 AMD 1 - SHOWER ENCLOSURES - FUNCTIONAL REQUIREMENTS AND TEST METHODS |
10/30193723 DC : 0 | BS ISO 11336-1 - LARGE YACHTS STRENGTH, WEATHERTIGHTNESS AND WATERTIGHTNESS OF GLAZED OPENINGS - PART 1: DESIGN CRITERIA, MATERIALS, FRAMING AND TESTING OF INDEPENDENT GLAZED OPENINGS |
BS EN 61730-2 : 2007 | PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 2: REQUIREMENTS FOR TESTING |
BS ISO 11336-1:2012 | Large yachts. Strength, weathertightness and watertightness of glazed openings Design criteria, materials, framing and testing of independent glazed openings |
BS EN 12521:2015 | Furniture. Strength, durability and safety. Requirements for domestic tables |
03/101907 DC : DRAFT AUG 2003 | EN 14727 - LABORATORY FURNITURE - STORAGE UNITS FOR LABORATORIES - REQUIREMENTS AND TEST METHODS |
DIN EN 15682-1:2013-10 | GLASS IN BUILDING - HEAT SOAKED THERMALLY TOUGHENED ALKALINE EARTH SILICATE SAFETY GLASS - PART 1: DEFINITION AND DESCRIPTION |
BS EN 16005:2012 | Power operated pedestrian doorsets. Safety in use. Requirements and test methods |
UNE-EN 12521:2016 | Furniture - Strength, durability and safety - Requirements for domestic tables |
13/30281354 DC : 0 | BS EN 16612 - GLASS IN BUILDING - DETERMINATION OF THE LOAD RESISTANCE OF GLASS PANES BY CALCULATION AND TESTING |
17/30356436 DC : 0 | BS EN 16612 - GLASS IN BUILDING - DETERMINATION OF THE LATERAL LOAD RESISTANCE OF GLASS PANES BY CALCULATION |
UNI EN 1279-5 : 2010 | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY |
NF EN 12758 : 2011 | GLASS IN BUILDING - GLAZING AND AIRBORNE SOUND INSULATION - PRODUCT DESCRIPTIONS AND DETERMINATION OF PROPERTIES |
DIN EN 1096-4:2015-06 (Draft) | GLASS IN BUILDING - COATED GLASS - PART 4: EVALUATION OF CONFORMITY/PRODUCT STANDARD |
I.S. EN 12758:2011 | GLASS IN BUILDING - GLAZING AND AIRBORNE SOUND INSULATION - PRODUCT DESCRIPTIONS AND DETERMINATION OF PROPERTIES |
BS EN 12758:2011 | Glass in building. Glazing and airborne sound insulation. Product descriptions and determination of properties |
BS EN 1096-1:2012 | Glass in building. Coated glass Definitions and classification |
BS EN 618 : 2002 | |
BS EN 357:2004 | Glass in building. Fire resistant glazed elements with transparent or translucent glass products. Classification of fire resistance |
I.S. EN 14010:2004 | |
EN 1096-3:2012 | Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings |
DIN EN 12312-4:2003-09 | AIRCRAFT GROUND SUPPORT EQUIPMENT - SPECIFIC REQUIREMENTS - PART 4: PASSENGER BOARDING BRIDGES |
DIN EN 16477-1:2017-07 | GLASS IN BUILDING - PAINTED GLASS FOR INTERNAL USE - PART 1: REQUIREMENTS |
EN 12312-4:2014 | Aircraft ground support equipment - Specific requirements - Part 4: Passenger boarding bridges |
EN 12758:2011 | Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties |
EN 12150-2:2004 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard |
EN 61730-2:2007/A1:2012 | PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 2: REQUIREMENTS FOR TESTING (IEC 61730-2:2004/A1:2011) |
EN 14749:2016 | Furniture - Domestic and kitchen storage units and kitchen-worktops - Safety requirements and test methods |
PREN 12521 : DRAFT 2015 | FURNITURE - STRENGTH, DURABILITY AND SAFETY - REQUIREMENTS FOR DOMESTIC TABLES |
BS EN 15683-1:2013 | Glass in building. Thermally toughened soda lime silicate channel shaped safety glass Definition and description |
12/30255284 DC : DRAFT APR 2012 | BS EN 1096-4 - GLASS IN BUILDING - COATED GLASS - PART 4: EVALUATION OF CONFORMITY - PRODUCT STANDARD |
PREN 14749 : DRAFT 2013 | DOMESTIC AND KITCHEN STORAGE UNITS AND WORKTOPS - SAFETY REQUIREMENTS AND TEST METHODS |
UNI EN 15683-1 : 2013 | GLASS IN BUILDING - THERMALLY TOUGHENED SODA LIME SILICATE CHANNEL SHAPED SAFETY GLASS - PART 1: DEFINITION AND DESCRIPTION |
17/30351893 DC : 0 | BS EN 17074 - GLASS IN BUILDING - ENVIRONMENTAL PRODUCT DECLARATION - PRODUCT CATEGORY RULES FOR FLAT GLASS PRODUCTS |
BS EN 15372:2016 | Furniture. Strength, durability and safety. Requirements for non-domestic tables |
PREN 12150-2 : DRAFT 2017 | GLASS IN BUILDING - THERMALLY TOUGHENED SODA LIME SILICATE SAFETY GLASS - PART 2: PRODUCT STANDARD |
I.S. EN 1279-1:2004 | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 1: GENERALITIES, DIMENSIONAL TOLERANCES AND RULES FOR THE SYSTEM DESCRIPTION |
I.S. EN 16121:2013 | NON-DOMESTIC STORAGE FURNITURE - REQUIREMENTS FOR SAFETY, STRENGTH, DURABILITY AND STABILITY |
PREN 14449 : DRAFT 2017 | GLASS IN BUILDING - LAMINATED GLASS AND LAMINATED SAFETY GLASS - PRODUCT STANDARD |
EN 1096-4:2004 | Glass in building - Coated glass - Part 4: Evaluation of conformity/Product standard |
EN 13031-1:2001 | Greenhouses - Design and construction - Part 1: Commercial production greenhouses |
DIN EN 620:2011-07 | Continuous handling equipment and systems - Safety and EMC requirements for fixed belt conveyors for bulk materials (includes Amendment A1:2010) |
DIN EN 14010:2009-12 | Safety of machinery - Equipment for power driven parking of motor vehicles - Safety and EMC requirements for design, manufacturing, erection and commissioning stages (includes Amendment A1:2009) |
DIN EN 1279-5:2015-08 (Draft) | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY |
DIN EN 14449:2005-07 | Glass in building - Laminated glass and laminated safety glass - Evaluation of conformity/Product standard |
DIN EN 14749:2016-06 | Furniture - Domestic and kitchen storage units and kitchen-worktops - Safety requirements and test methods |
BS EN 581-3:2017 | Outdoor furniture. Seating and tables for camping, domestic and contract use Mechanical safety requirements for tables |
BS EN 620 : 2002 | |
DIN EN 12758:2011-04 | GLASS IN BUILDING - GLAZING AND AIRBORNE SOUND INSULATION - PRODUCT DESCRIPTIONS AND DETERMINATION OF PROPERTIES |
I.S. EN 14749:2016 | FURNITURE - DOMESTIC AND KITCHEN STORAGE UNITS AND KITCHEN-WORKTOPS - SAFETY REQUIREMENTS AND TEST METHODS |
I.S. EN 581-3:2017 | OUTDOOR FURNITURE - SEATING AND TABLES FOR CAMPING, DOMESTIC AND CONTRACT USE - PART 3: MECHANICAL SAFETY REQUIREMENTS FOR TABLES |
I.S. EN 12312-4:2014 | AIRCRAFT GROUND SUPPORT EQUIPMENT - SPECIFIC REQUIREMENTS - PART 4: PASSENGER BOARDING BRIDGES |
I.S. EN 1096-3:2012 | GLASS IN BUILDING - COATED GLASS - PART 3: REQUIREMENTS AND TEST METHODS FOR CLASS C AND D COATINGS |
I.S. EN 357:2004 | GLASS IN BUILDING - FIRE RESISTANT GLAZED ELEMENTS WITH TRANSPARENT OR TRANSLUCENT GLASS PRODUCTS - CLASSIFICATION OF FIRE RESISTANCE |
I.S. EN 618:2002 | |
I.S. EN 620:2002 | |
I.S. EN 1096-1:2012 | GLASS IN BUILDING - COATED GLASS - PART 1: DEFINITIONS AND CLASSIFICATION |
08/30173305 DC : DRAFT JAN 2008 | BS EN 15755-1 - GLASS IN BUILDING - ADHESIVE BACKED POLYMERIC FILMED GLASS - PART 1: DEFINITIONS AND DESCRIPTION |
UNI EN 16005 : 2012 | POWER OPERATED PEDESTRIAN DOORSETS - SAFETY IN USE - REQUIREMENTS AND TEST METHODS |
02/102720 DC : DRAFT APR 2002 | PREN 14428 - SHOWER ENCLOSURES - FUNCTIONAL REQUIREMENTS AND TEST METHODS |
I.S. EN 16005:2012 | POWER OPERATED PEDESTRIAN DOORSETS - SAFETY IN USE - REQUIREMENTS AND TEST METHODS |
14/30281866 DC : 0 | BS ISO 18178 - GLASS IN BUILDING - LAMINATED SOLAR PV GLASS |
08/30173498 DC : DRAFT JAN 2008 | BS EN 12521 - FURNITURE - STRENGTH, DURABILITY AND SAFETY - REQUIREMENTS FOR DOMESTIC TABLES |
10/30227092 DC : 0 | BS EN 16121 - NON-DOMESTIC STORAGE FURNITURE - REQUIREMENTS FOR SAFETY, STRENGTH, DURABILITY AND STABILITY |
DIN EN 16005:2013-01 | Power operated pedestrian doorsets - Safety in use - Requirements and test methods |
UNE-EN 16477-1:2017 | Glass in building - Painted glass for internal use - Part 1: Requirements |
DIN EN 15372:2015-08 (Draft) | FURNITURE - STRENGTH, DURABILITY AND SAFETY - REQUIREMENTS FOR NON-DOMESTIC TABLES |
11/30244795 DC : 0 | BS EN 1096-1 - GLASS IN BUILDING - COATED GLASS - PART 1: DEFINITIONS AND CLASSIFICATION |
DIN EN 15683-1:2014-01 | GLASS IN BUILDING - THERMALLY TOUGHENED SODA LIME SILICATE CHANNEL SHAPED SAFETY GLASS - PART 1: DEFINITION AND DESCRIPTION |
08/30170590 DC : DRAFT JULY 2008 | BS EN ISO 12543-1 - GLASS IN BUILDING - LAMINATED GLASS AND LAMINATED SAFETY GLASS - PART 1: DEFINITIONS AND DESCRIPTION OF COMPONENT PARTS |
I.S. EN 16477-1:2016 | GLASS IN BUILDING - PAINTED GLASS FOR INTERNAL USE - PART 1: REQUIREMENTS |
I.S. EN 61730-2:2007 | PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 2: REQUIREMENTS FOR TESTING (IEC 61730-2:2004 (MOD)) |
I.S. EN 12521:2015 | FURNITURE - STRENGTH, DURABILITY AND SAFETY - REQUIREMENTS FOR DOMESTIC TABLES |
I.S. EN 15372:2016 | FURNITURE - STRENGTH, DURABILITY AND SAFETY - REQUIREMENTS FOR NON-DOMESTIC TABLES |
NF EN 1279-5 : 2005 + A2 2010 | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY |
BS EN 1096-4:2004 | Glass in building. Coated glass Evaluation of conformity/Product standard |
I.S. EN 13031-1:2002 | GREENHOUSES: DESIGN AND CONSTRUCTION - PART 1: COMMERCIAL PRODUCTION GREENHOUSES |
UNE-EN 12758:2011 | Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties |
I.S. EN 1279-5:2005 | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY |
DIN EN 12150-2:2005-01 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard; German version EN 12150-2:2004 |
DIN EN 1096-3:2012-04 | Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings |
UNE-EN 1096-3:2012 | Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings |
EN 618:2002+A1:2010 | Continuous handling equipment and systems - Safety and EMC requirements for equipment for mechanical handling of bulk materials except fixed belt conveyors |
EN 15372:2016 | Furniture - Strength, durability and safety - Requirements for non-domestic tables |
EN 581-3:2017 | Outdoor furniture - Seating and tables for camping, domestic and contract use - Part 3: Mechanical safety requirements for tables |
UNI EN 1096-3 : 2012 | GLASS IN BUILDING - COATED GLASS - PART 3: REQUIREMENTS AND TEST METHODS FOR CLASS C AND D COATINGS |
UNI EN 12758 : 2011 | GLASS IN BUILDING - GLAZING AND AIRBORNE SOUND INSULATION - PRODUCT DESCRIPTIONS AND DETERMINATION OF PROPERTIES |
UNI EN 14449 : 2005 | GLASS IN BUILDING - LAMINATED GLASS AND LAMINATED SAFETY GLASS - EVALUATION OF CONFORMITY/PRODUCT STANDARD |
UNI EN 618 : 2011 | CONTINUOUS HANDLING EQUIPMENT AND SYSTEMS - SAFETY AND EMC REQUIREMENTS FOR EQUIPMENT FOR MECHANICAL HANDLING OF BULK MATERIALS EXCEPT FIXED BELT CONVEYORS |
UNI EN 1096-1 : 2012 | Glass in building - Coated glass - Part 1: Definitions and classification |
UNI EN 14010 : 2009 | SAFETY OF MACHINERY - EQUIPMENT FOR POWER DRIVEN PARKING OF MOTOR VEHICLES - SAFETY AND EMC REQUIREMENTS FOR DESIGN, MANUFACTURING, ERECTION AND COMMISSIONING STAGES |
UNI EN 15682-1 : 2013 | GLASS IN BUILDING - HEAT SOAKED THERMALLY TOUGHENED ALKALINE EARTH SILICATE SAFETY GLASS - PART 1: DEFINITION AND DESCRIPTION |
UNI EN 12312-4 : 2014 | AIRCRAFT GROUND SUPPORT EQUIPMENT - SPECIFIC REQUIREMENTS - PART 4: PASSENGER BOARDING BRIDGES |
BS EN 16477-1:2016 | Glass in building. Painted glass for internal use Requirements |
DIN EN 12521:2016-03 | Furniture - Strength, durability and safety - Requirements for domestic tables |
EN 1279-5:2005+A2:2010 | Glass in building - Insulating glass units - Part 5: Evaluation of conformity |
14/30284850 DC : 0 | BS EN 15372 - FURNITURE - STRENGTH, DURABILITY AND SAFETY - REQUIREMENTS FOR NON-DOMESTIC TABLES |
PREN 16612 : DRAFT 2017 | GLASS IN BUILDING - DETERMINATION OF THE LATERAL LOAD RESISTANCE OF GLASS PANES BY CALCULATION |
UNE-EN 15372:2017 | Furniture - Strength, durability and safety - Requirements for non-domestic tables |
18/30334473 DC : 0 | BS ISO 11336-3 - LARGE YACHTS - STRENGTH, WEATHERTIGHTNESS AND WATERTIGHTNESS OF GLAZED OPENINGS - PART 3: QUALITY ASSURANCE, INSTALLATION AND IN-SERVICE INSPECTION |
BS EN 15682-1:2013 | Glass in building. Heat soaked thermally toughened alkaline earth silicate safety glass Definition and description |
BS EN 15755-1:2014 | Glass in building. Adhesive backed polymeric filmed glass Definitions and requirements |
PREN 1096-3 : DRAFT 2011 | GLASS IN BUILDING - COATED GLASS - PART 3: REQUIREMENTS AND TEST METHODS FOR CLASS C AND D COATINGS |
ISO 11336-1:2012 | Large yachts — Strength, weathertightness and watertightness of glazed openings — Part 1: Design criteria, materials, framing and testing of independent glazed openings |
I.S. EN 15755-1:2014 | GLASS IN BUILDING - ADHESIVE BACKED POLYMERIC FILMED GLASS - PART 1: DEFINITIONS AND REQUIREMENTS |
PREN 13031-1 : DRAFT 2017 | GREENHOUSES - DESIGN AND CONSTRUCTION - PART 1: COMMERCIAL PRODUCTION GREENHOUSES |
PREN 15372 : DRAFT 2014 | FURNITURE - STRENGTH, DURABILITY AND SAFETY - REQUIREMENTS FOR NON-DOMESTIC TABLES |
UNE-EN 15755-1:2015 | Glass in building - Adhesive backed polymeric filmed glass - Part 1: Definitions and requirements |
DIN EN 1288-1:2000-09 | GLASS IN BUILDING - DETERMINATION OF THE BENDING STRENGTH OF GLASS - PART 1: FUNDAMENTALS OF TESTING GLASS |
EN 620:2002+A1:2010 | Continuous handling equipment and systems - Safety and EMC requirements for fixed belt conveyors for bulk materials |
DIN EN 618:2011-06 | Continuous handling equipment and systems - Safety and EMC requirements for equipment for mechanical handling of bulk materials except fixed belt conveyors |
DIN EN 13031-1:2003-09 | GREENHOUSES - DESIGN AND CONSTRUCTION - PART 1: COMMERCIAL PRODUCTION GREENHOUSES |
UNE-EN 16121:2014 | Non-domestic storage furniture - Requirements for safety, strength, durability and stability |
UNE-EN 1096-1:2012 | Glass in building - Coated glass - Part 1: Definitions and classification |
UNE-EN 14749:2016 | Furniture - Domestic and kitchen storage units and kitchen-worktops - Safety requirements and test methods |
BS EN 1288-1:2000 | Glass in building. Determination of the bending strength of glass Fundamentals of testing glass |
UNE-EN 61730-2:2007 | Photovoltaic (PV) module safety qualification - Part 2: Requirements for testing |
UNE-EN 581-3:2017 | Outdoor furniture - Seating and tables for camping, domestic and contract use - Part 3: Mechanical safety requirements for tables |
BS EN 12312-4:2014 | Aircraft ground support equipment. Specific requirements Passenger boarding bridges |
UNE-EN 16005:2013 | Power operated pedestrian doorsets - Safety in use - Requirements and test methods |
BS EN 14010 : 2003 | |
BS EN 14749:2016 | Furniture. Domestic and kitchen storage units and kitchen-worktops. Safety requirements and test methods |
UNE-EN 620:2002 | Continuous handling equipment and systems - Safety and EMC requirements for fixed belt conveyors for bulk materials |
BS EN 14449:2005 | Glass in building. Laminated glass and laminated safety glass. Evaluation of conformity/product standard |
UNE-EN 618:2002 | Continuous handling equipment and systems - Safety and EMC requirements for equipment for mechanical handling of bulk materials except fixed belt conveyors. |
BS EN 13031-1:2001 | Greenhouses. Design and construction Commercial production greenhouses |
EN 15683-1:2013 | Glass in building - Thermally toughened soda lime silicate channel shaped safety glass - Part 1: Definition and description |
EN 16121:2013+A1:2017 | Non-domestic storage furniture - Requirements for safety, strength, durability and stability |
EN 357:2004 | Glass in building - Fire resistant glazed elements with transparent or translucent glass products - Classification of fire resistance |
EN 15682-1:2013 | Glass in building - Heat soaked thermally toughened alkaline earth silicate safety glass - Part 1: Definition and description |
EN 15755-1:2014 | Glass in building - Adhesive backed polymeric filmed glass - Part 1: Definitions and requirements |
EN 16477-1:2016 | Glass in building - Painted glass for internal use - Part 1: Requirements |
EN 14010:2003+A1:2009 | Safety of machinery - Equipment for power driven parking of motor vehicles - Safety and EMC requirements for design, manufacturing, erection and commissioning stages |
PREN 1096-1 : DRAFT 2011 | GLASS IN BUILDING - COATED GLASS - PART 1: DEFINITIONS AND CLASSIFICATION |
11/30244801 DC : 0 | BS EN 1096-3 - GLASS IN BUILDING - COATED GLASS - PART 3: REQUIREMENTS AND TEST METHODS FOR CLASS C AND D COATINGS |
DIN EN 15755-1:2014-10 | GLASS IN BUILDING - ADHESIVE BACKED POLYMERIC FILMED GLASS - PART 1: DEFINITIONS AND REQUIREMENTS |
14/30295268 DC : 0 | BS EN 581-3 - OUTDOOR FURNITURE - SEATING AND TABLES FOR CAMPING, DOMESTIC AND CONTRACT USE - PART 3: SAFETY, STRENGTH AND DURABILITY REQUIREMENTS FOR TABLES |
08/30172148 DC : DRAFT MAY 2008 | BS ISO 28278-1 - GLASS IN BUILDING - GLASS PRODUCTS FOR STRUCTURAL SEALANT GLAZING - PART 1: SUPPORTED AND UNSUPPORTED MONOLITHIC AND MULTIPLE GLAZING |
13/30283767 DC : 0 | BS EN 14749 - DOMESTIC AND KITCHEN STORAGE UNITS AND WORKTOPS - SAFETY REQUIREMENTS AND TEST METHODS |
15/30320771 DC : 0 | BS EN 12521 - FURNITURE - STRENGTH, DURABILITY AND SAFETY - REQUIREMENTS FOR DOMESTIC TABLES |
I.S. EN 15682-1:2013 | GLASS IN BUILDING - HEAT SOAKED THERMALLY TOUGHENED ALKALINE EARTH SILICATE SAFETY GLASS - PART 1: DEFINITION AND DESCRIPTION |
07/30046980 DC : DRAFT AUG 2007 | BS ISO 1288-1 - GLAZING IN BUILDING - DETERMINATION OF THE BENDING STRENGTH OF GLASS - PART 1: FUNDAMENTALS OF TESTING GLASS |
I.S. EN 15683-1:2013 | GLASS IN BUILDING - THERMALLY TOUGHENED SODA LIME SILICATE CHANNEL SHAPED SAFETY GLASS - PART 1: DEFINITION AND DESCRIPTION |
08/30170610 DC : DRAFT OCT 2008 | BS EN ISO 12543-5 - GLASS IN BUILDING - LAMINATED GLASS AND LAMINATED SAFETY GLASS - PART 5: DIMENSIONS AND EDGE FINISHING |
BS EN 16121 : 2013 | NON-DOMESTIC STORAGE FURNITURE - REQUIREMENTS FOR SAFETY, STRENGTH, DURABILITY AND STABILITY |
PREN 581-3 : DRAFT 2014 | OUTDOOR FURNITURE - SEATING AND TABLES FOR CAMPING, DOMESTIC AND CONTRACT USE - PART 3: SAFETY, STRENGTH AND DURABILITY REQUIREMENTS FOR TABLES |
I.S. EN 1096-4:2004 | GLASS IN BUILDING - COATED GLASS - PART 4: EVALUATION OF CONFORMITY/PRODUCT STANDARD |
BS EN 1279-5 : 2005 | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY |
UNE-EN 15683-1:2014 | Glass in building - Thermally toughened soda lime silicate channel shaped safety glass - Part 1: Definition and description |
17/30354665 DC : 0 | BS EN 13031-1 - GREENHOUSES - DESIGN AND CONSTRUCTION - PART 1: COMMERCIAL PRODUCTION GREENHOUSES |
DIN EN 1279-1:2015-08 (Draft) | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 1: GENERALITIES, DIMENSIONAL TOLERANCES AND RULES FOR THE SYSTEM DESCRIPTION |
BS EN 1279-1:2004 | Glass in building. Insulating glass units Generalities, dimensional tolerances and rules for the system description |
DIN EN 16477-1:2016-07 (Draft) | GLASS IN BUILDING - PAINTED GLASS FOR INTERNAL USE - PART 1: REQUIREMENTS |
DIN EN 1096-1:2012-04 | Glass in building - Coated glass - Part 1: Definitions and classification |
BS EN 1096-3:2012 | Glass in building. Coated glass Requirements and test methods for class C and D coatings |
UNE-EN 12312-4:2015 | Aircraft ground support equipment - Specific requirements - Part 4: Passenger boarding bridges |
BS EN 12600:2002 | Glass in building. Pendulum test. Impact test method and classification for flat glass |
BS EN 12150-2:2004 | Glass in building. Thermally toughened soda lime silicate safety glass Evaluation of conformity/Product standard |
EN 1096-1:2012 | Glass in building - Coated glass - Part 1: Definitions and classification |
EN 12600:2002 | Glass in building - Pendulum test - Impact test method and classification for flat glass |
DIN EN 15372:2017-02 | Furniture - Strength, durability and safety - Requirements for non-domestic tables; German version EN 15372:2016 |
DIN EN 357:2005-02 | GLASS IN BUILDING - FIRE-RESISTANT GLAZED ELEMENTS WITH TRANSPARENT OR TRANSLUCENT GLASS PRODUCTS - CLASSIFICATION OF FIRE RESISTANCE |
UNI EN 620 : 2011 | CONTINUOUS HANDLING EQUIPMENT AND SYSTEMS - SAFETY AND EMC REQUIREMENTS FOR FIXED BELT CONVEYORS FOR BULK MATERIALS |
EN 1288-1:2000 | Glass in building - Determination of the bending strength of glass - Part 1: Fundamentals of testing glass |
EN 12521:2015 | Furniture - Strength, durability and safety - Requirements for domestic tables |
UNE-EN 1279-5:2006 | Glass in building - Insulating glass units - Part 5: Evaluation of conformity |
EN 14179-1:2016 | Glass in building - Heat soaked thermally toughened soda lime silicate safety glass - Part 1: Definition and description |
EN 1096-1:2012 | Glass in building - Coated glass - Part 1: Definitions and classification |
EN 14428:2015 | Shower enclosures - Functional requirements and test methods |
ISO 11485-1:2011 | Glass in building — Curved glass — Part 1: Terminology and definitions |
EN 1288-3:2000 | Glass in building - Determination of the bending strength of glass - Part 3: Test with specimen supported at two points (four point bending) |
EN 572-2:2012 | Glass in building - Basic soda lime silicate glass products - Part 2: Float glass |
ISO 11485-3:2014 | Glass in building Curved glass Part 3: Requirements for curved tempered and curved laminated safety glass |
EN 572-4:2012 | Glass in building - Basic soda lime silicate glass products - Part 4: Drawn sheet glass |
EN 572-1:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties |
ISO 11485-2:2011 | Glass in building — Curved glass — Part 2: Quality requirements |
EN 572-5:2012 | Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass |
EN 572-8:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 8: Supplied and final cut sizes |
EN 12600:2002 | Glass in building - Pendulum test - Impact test method and classification for flat glass |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.