EN 1096-4:2004
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Glass in building - Coated glass - Part 4: Evaluation of conformity/Product standard
02-18-2022
10-13-2004
1 Scope
2 Normative references
3 Terms, definitions and symbols
3.1 Terms and definitions
3.1.1 Initial type testing
3.1.2 Test report
3.1.3 Product description
3.1.4 Significant change
3.2 Symbols
4 Requirements
4.1 Product description
4.2 Conformity with the definition of coated glass
4.3 Determination of the characteristic's performances
4.3.1 Characteristic of coated glass
4.3.2 Determination of characteristics of coated glass
4.4 Durability
4.5 Dangerous substances
5 Evaluation of conformity
5.1 General
5.2 Initial type testing of the product
5.2.1 General
5.2.2 Initial type testing of coated glass
5.2.3 Initial type testing of characteristic's performances
5.3 Factory production control and inspection of samples in
accordance with a prescribed test plan
5.4 Initial inspection of factory and of factory production
control
5.5 Continuous surveillance and assessment of the factory
production control
6 Marking and/or labelling
6.1 General
6.2 Product marking
6.3 Product characteristics
6.4 'Characteristics/performance identification paper'
7 Initial type testing; sampling and measurement of photometric
and energy characteristics
7.1 Sampling
7.1.1 General
7.1.2 Sample specification
7.2 Measurement of photometric and energy characteristics
Annex A (normative) Factory production control
A.1 Factory Production Control Requirements
A.1.1 General
A.1.2 Organisation
A.1.3 Control system
A.2 Marking
A.3 Inspection and testing tables of coated glass product
production
A.3.1 Information on Tables A.1 and A.2
A.3.2 Comments specific to Table A.1
A.3.3 Comments specific to Table A.2
A.3.4 Use of proxy testing
Annex B (informative) Tests for factory production control
B.1 General
B.2 Radiometric properties
B.2.1 Sampling
B.2.2 Measurements
B.3 Information on ensuring durability conformity
Annex C (informative) Provisions for voluntary involvement of
third party(ies)
C.1 General
C.2 Voluntary tasks for third parties
C.3 Marking and labelling
Annex ZA (informative) Clauses of this European Standard
addressing the provisions of EU Construction Products
Directive
ZA.1 Scope and relevant characteristics
ZA.2 Procedure(s) for the attestation of conformity of
coated glass products
ZA.2.1 System(s) of attestation of conformity
ZA.2.2 EC Certificate and Declaration of conformity
ZA.3 CE marking and labelling
Bibliography
This document covers the evaluation of conformity and the factory production control of coated glass for use in buildings. Note: For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.
Committee |
CEN/TC 129
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
BS EN 1096-4:2004 | Identical |
NF EN 1096-4 : 2005 | Identical |
NEN EN 1096-4 : 2004 | Identical |
PN EN 1096-4 : 2018 | Identical |
NEN-EN 1096-4:2018 en | Identical |
NBN EN 1096-4 : 2005 | Identical |
DIN EN 1096-4:2015-06 (Draft) | Identical |
BS EN 1096-4:2018 | Identical |
ÖNORM EN 1096-4: 2019 | Identical |
DIN EN 1096-4:2018-11 | Identical |
NS EN 1096-4 : 1ED 2004 | Identical |
UNI EN 1096-4 : 2005 | Identical |
I.S. EN 1096-4:2004 | Identical |
PN EN 1096-4 : 2006 | Identical |
UNI EN 1096-4:2018 | Identical |
I.S. EN 1096-4:2018 | Identical |
ONORM EN 1096-4 : 2004 | Identical |
UNE-EN 1096-4:2005 | Identical |
SN EN 1096-4 : 2004 | Identical |
UNI EN 15998 : 2011 | GLASS IN BUILDING - SAFETY IN CASE OF FIRE, FIRE RESISTANCE - GLASS TESTING METHODOLOGY FOR THE PURPOSE OF CLASSIFICATION |
PREN 15254-4 : DRAFT 2016 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
DIN EN 15254-4:2013-10 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
DIN EN 13022-2:2014-08 | GLASS IN BUILDING - STRUCTURAL SEALANT GLAZING - PART 2: ASSEMBLY RULES |
UNE-EN 13022-2:2015 | Glass in building - Structural sealant glazing - Part 2: Assembly rules |
DIN EN 13830:2015-07 | CURTAIN WALLING - PRODUCT STANDARD |
EN 13022-2:2014 | Glass in building - Structural sealant glazing - Part 2: Assembly rules |
PREN 13830 : DRAFT 2013 | CURTAIN WALLING - PRODUCT STANDARD |
13/30281348 DC : 0 | BS EN 13830 - CURTAIN WALLING - PRODUCT STANDARD |
EN 15254-4:2008+A1:2011 | Extended application of results from fire resistance tests - Non-loadbearing walls - Part 4: Glazed constructions |
DIN EN 14449:2005-07 | Glass in building - Laminated glass and laminated safety glass - Evaluation of conformity/Product standard |
UNE-EN 13830:2016 | Curtain walling - Product standard |
I.S. EN 13830:2015 | CURTAIN WALLING - PRODUCT STANDARD |
I.S. EN 14351-1:2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND/OR SMOKE LEAKAGE CHARACTERISTICS |
I.S. EN 13022-2:2014 | GLASS IN BUILDING - STRUCTURAL SEALANT GLAZING - PART 2: ASSEMBLY RULES |
I.S. EN 14600:2005 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
05/30134012 DC : 0 | EN 15254-4 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTION |
12/30266506 DC : 0 | BS EN 50583 - PHOTOVOLTAICS IN BUILDINGS |
UNE-EN 15998:2011 | Glass in building - Safety in case of fire, fire resistance - Glass testing methodology for the purpose of classification |
BS EN 14600:2005 | Doorsets and openable windows with fire resisting and/ or smoke control characteristics. Requirements and classification |
EN 13830:2015 | Curtain walling - Product standard |
EN 15998:2010 | Glass in building - Safety in case of fire, fire resistance - Glass testing methodology for the purpose of classification |
UNI EN 14600 : 2006 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
UNI EN 14449 : 2005 | GLASS IN BUILDING - LAMINATED GLASS AND LAMINATED SAFETY GLASS - EVALUATION OF CONFORMITY/PRODUCT STANDARD |
UNI EN 13022-2 : 2014 | GLASS IN BUILDING - STRUCTURAL SEALANT GLAZING - PART 2: ASSEMBLY RULES |
DIN EN 15998:2011-02 | GLASS IN BUILDING - SAFETY IN CASE OF FIRE, FIRE RESISTANCE - GLASS TESTING METHODOLOGY FOR THE PURPOSE OF CLASSIFICATION |
PREN 50583 : DRAFT 2012 | PHOTOVOLTAICS IN BUILDINGS |
BS EN 15998:2010 | Glass in building. Safety in case of fire, fire resistance. Glass testing methodology for the purpose of classification |
18/30334473 DC : 0 | BS ISO 11336-3 - LARGE YACHTS - STRENGTH, WEATHERTIGHTNESS AND WATERTIGHTNESS OF GLAZED OPENINGS - PART 3: QUALITY ASSURANCE, INSTALLATION AND IN-SERVICE INSPECTION |
I.S. EN 15998:2010 | GLASS IN BUILDING - SAFETY IN CASE OF FIRE, FIRE RESISTANCE - GLASS TESTING METHODOLOGY FOR THE PURPOSE OF CLASSIFICATION |
BS EN 14351-1 : 2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS |
BS EN 13830:2015 | Curtain walling. Product standard |
BS EN 14449:2005 | Glass in building. Laminated glass and laminated safety glass. Evaluation of conformity/product standard |
EN 14351-1:2006+A2:2016 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets |
EN 14600:2005 | Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification |
16/30347433 DC : 0 | BS EN 15254-4 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
UNE-EN 50583-1:2016 | Photovoltaics in buildings - Part 1: BIPV modules |
BS EN 50583-1:2016 | Photovoltaics in buildings BIPV modules |
12/30266556 DC : 0 | BS EN 16477-1 - GLASS IN BUILDING - PAINTED GLASS FOR INTERNAL USE - PART 1: REQUIREMENTS |
I.S. EN 50583-1:2016 | PHOTOVOLTAICS IN BUILDINGS - PART 1: BIPV MODULES |
UNI EN 15254-4 : 2011 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
UNE-EN 15254-4:2009 | Extended application of results from fire resistance tests - Non-loadbearing walls - Part 4: Glazed constructions |
BS EN 15254-4 : 2008 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
I.S. EN 15254-4:2008 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
BS EN 13022-2:2014 | Glass in building. Structural sealant glazing Assembly rules |
EN 50583-1:2016 | Photovoltaics in buildings - Part 1: BIPV modules |
DIN EN 14600:2006-03 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
UNE-EN 14351-1:2006 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics |
EN 572-3:2012 | Glass in building - Basic soda lime silicate glass products - Part 3: Polished wired glass |
PREN 13501-5 : DRAFT 2015 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 5: CLASSIFICATION USING DATA FROM EXTERNAL FIRE EXPOSURE TO ROOFS TESTS |
EN 12337-1:2000 | Glass in building - Chemically strengthened soda lime silicate glass - Part 1: Definition and description |
EN 13024-1:2011 | Glass in building - Thermally toughened borosilicate safety glass - Part 1: Definition and description |
EN 673:2011 | Glass in building - Determination of thermal transmittance (U value) - Calculation method |
EN 1748-2-1:2004 | Glass in building - Special basic products - Glass ceramics - Part 2-1 Definitions and general physical and mechanical properties |
EN 12758:2011 | Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties |
PREN 14179-1 : DRAFT 2014 | GLASS IN BUILDING - HEAT SOAKED THERMALLY TOUGHENED SODA LIME SILICATE SAFETY GLASS - PART 1: DEFINITION AND DESCRIPTION |
EN 410:2011 | Glass in building - Determination of luminous and solar characteristics of glazing |
EN 572-7:2012 | Glass in building - Basic soda lime silicate glass products - Part 7: Wired or unwired channel shaped glass |
EN 1096-1:2012 | Glass in building - Coated glass - Part 1: Definitions and classification |
EN 12898:2001 | Glass in building - Determination of the emissivity |
EN 1863-1:2011 | Glass in building - Heat strengthened soda lime silicate glass - Part 1: Definition and description |
EN 14178-1:2004 | Glass in building - Basic alkaline earth silicate glass products - Part 1: Float glass |
EN 13541:2012 | Glass in building - Security glazing - Testing and classification of resistance against explosion pressure |
EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
EN 572-6:2012 | Glass in building - Basic soda lime silicate glass products - Part 6: Wired patterned glass |
EN 572-2:2012 | Glass in building - Basic soda lime silicate glass products - Part 2: Float glass |
EN 12150-1:2015 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 1: Definition and description |
ASTM D 1044 : 2013 : REDLINE | Standard Test Method for Resistance of Transparent Plastics to Surface Abrasion |
ISO 3537:2015 | Road vehicles Safety glazing materials Mechanical tests |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 1063:1999 | Glass in building - Security glazing - Testing and classification of resistance against bullet attack |
EN 1748-1-1:2004 | Glass in building - Special basic products -Borosilicate glasses - Part 1-1: Definition and general physical and mechanical properties |
EN 572-4:2012 | Glass in building - Basic soda lime silicate glass products - Part 4: Drawn sheet glass |
EN 357:2004 | Glass in building - Fire resistant glazed elements with transparent or translucent glass products - Classification of fire resistance |
ISO 12543-1:2011 | Glass in building Laminated glass and laminated safety glass Part 1: Definitions and description of component parts |
ISO 9001:2015 | Quality management systems — Requirements |
EN 572-1:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties |
EN 356:1999 | Glass in building - Security glazing - Testing and classification of resistance against manual attack |
EN 572-5:2012 | Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass |
EN 1096-3:2012 | Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings |
EN ISO 12543-1:2011 | Glass in building - Laminated glass and laminated safety glass - Part 1: Definitions and description of component parts (ISO 12543-1:2011) |
EN 12600:2002 | Glass in building - Pendulum test - Impact test method and classification for flat glass |
EN 1096-2:2012 | Glass in building - Coated glass - Part 2: Requirements and test methods for class A, B and S coatings |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.